Progress
A tender has been published for Border Security Force (bsf) Optical Time Domain Reflectometer (OTDR) (Q3) in NEW DELHI, DELHI. Quantity: 196 by. Submission Deadline: 01-09-2026 12: 00: 00. Check eligibility and apply.
Quantity
196
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
Yes
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
5 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
116
OEM Avg. Turnover
232
Past Performance
20 %
Warranty Period
15 days
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Optical Time Domain Reflectometer (OTDR) (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
40
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
New Delhi
Delivery Pincodes
110003
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Chandra Prakash | 110003,DDO FHQ BSF , BLOCK NO. 10, CGO COMLEX, LODHI ROAD, NEW DELHI - 110003 | New Delhi | Delhi | 110003 | 196 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
01-Sep-2026, 6:30 am
Opening Date
01-Sep-2026, 7:00 am
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE | Fiber Compatibility | Single Mode |
| PERFORMANCE | Central Wavelength (nm) | 1310 & 1550 and 1625 / 1650 for for Single Mode & live Fiber testing, 1310 & 1550 for Single Mode; |
| PERFORMANCE | Wavelength Tolerance (±) | 25.0 Or lower |
| PERFORMANCE | Dynamic range@ Max Wavelength | 42.0 - 50.0 Or higher |
| PERFORMANCE | Event dead zone - Maximum | 0.6 Or lower |
| PERFORMANCE | Attenuation dead zone - Maximum | Up to 8 |
| PERFORMANCE | Maximum Display Distance Range | 300.0, 200.0 |
| PERFORMANCE | Pulse width Range | 3 to 20000 for Single Mode/Live Fiber Testing |
| PERFORMANCE | Distance Measurement Accuracy (±) | 0.75 Or lower |
| PERFORMANCE | Reflection Detection Accuracy (±) | ± 4 dB for Single Mode or better |
| PERFORMANCE | Sampling points | 256000.0 - 256000.0 Or higher |
| DISPLAY / STORAGE | Display | Colour Display, LCD, LED, TFT, Daylight Readable Display, Touch Screen, Backlit Display |
| DISPLAY / STORAGE | Display Size | 7.0 - 12.0 Or higher |
| DISPLAY / STORAGE | Connectivity interface | USB, RJ 45 |
| DISPLAY / STORAGE | Internal Storage OTDR traces | 1000 |
| DISPLAY / STORAGE | External Storage / Memory Stick Slot provided | USB |
| DISPLAY / STORAGE | External Storage Capacity inclusive in the scope of supply | 32 Or higher |
| STABILIZED LIGHT SOURCE | Modulation | CW, 270 Hz, 1 kHz, 2 kHz |
| POWER SOURCE | Power Source | Internal / Removable- Rechargeable Battery |
| POWER SOURCE | Battery Chemistry, if Rechargeable Battery | Li-Ion |
| POWER SOURCE | Battery Capacity (mAh) | 6400, 6600 |
| POWER SOURCE | Number of Batteries required for operation | 1 |
| POWER SOURCE | Number of Batteries supplied (Inclusive in the Scope of Supply) | 1 |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Built-in Visual Fault Locator (VFL) / Visual Light Source (VSL) | Yes |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Wave Length Range (VFL/VSL) | 650 nm ± 20 nm |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Maximum Optical output power (Peak) (VFL/VSL) - dBm | − 3 dBm or more |
| POWER METER FOR OTDR | Built-in Power Meter | No |
| POWER METER FOR OTDR | Power Meter input port | NA |
| POWER METER FOR OTDR | Wavelength Range | NA |
| POWER METER FOR OTDR | Modulation (Power Meter) | CW, 270 Hz, 1 kHz, 2 kHz |
| POWER METER FOR OTDR | Minimum Power measurement range (dBm) | -70.0 - -70.0 Or lower |
| POWER METER FOR OTDR | Maximum Power measurement range (dBm) | 10.0 - 50.0 Or higher |
| POWER METER FOR OTDR | Accuracy (Power Meter) (±) | 0.0 - 0.0 Or lower |
| GENERIC | Connector Tip | APC |
| SALIENT FEATURES | "Salient Features (Select Applicable Features Only)" | Supports 12 V External Battery |
| ACCESSORIES | Aceesories inclusive in the Scope of Supply (Select included Accessories Only) | Carry Case |
| OPERATING CONDITIONS | Minimum Operating Temperature | -10.0 Or lower |
| OPERATING CONDITIONS | Maximum Operating Temperature | 50.0 Or higher |
| OPERATING CONDITIONS | Maximum Operating Humidity | 95.0 - 95.0 Or higher |
| WARRANTY | WARRANTY | 3, 5 Or higher |
| CERTIFICATION | Availability of Test Reports from Central Govt/ NABL/ ILAC acredited lab to prove confirmity to the Specifications | Yes |
| CERTIFICATION | If Yes, Test Report to be furnished to the Buyer on demand | Yes |