Bid Publish Date
27-Feb-2026, 7:34 pm
Bid End Date
20-Mar-2026, 3:00 pm
EMD
₹80,000
Value
₹80,00,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Public procurement opportunity for Directorate Of Medical Education And Training High Performance Liquid Chromatography (HPLC) System (Q3) in Firozabad, UTTAR PRADESH. Quantity: 1 issued by. Submission Deadline: 20-03-2026 15: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
High Performance Liquid Chromatography (HPLC) System (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
| Category | Specification | Requirement |
|---|---|---|
| Set 1 | Number of samples the Analyser is capable to analyse (minimum), concurrently: | 10, 50, 100, 150 Or higher |
| Set 1 | Availability of a bi-directional Laboratory Interface System (LIS): | Yes, No |
| Set 1 | HPLC system have an inbuilt system check facility which checks that all the system parameters (eg, cartridge, buffer, reagent, waste etc) are ready before the sample analysis: | Yes, No |
| Set 1 | HPLC system have a dual program mode to perform either HbA1c or HbA2/Hb F/HbA1c without changing any reagents or columns: | Yes, No |
| Set 1 | HPLC system should not require changing of reagents while switching from HbA1c to HbA2/Hb F/HbA1c testing mode: | Yes, No |
| Set 1 | HPLC System offers both NGSP & IFCC value reporting on the same patient report, control & calibrator report: | Yes, No |
| Set 1 | If the HPLC system have feature of capillary collection kit for remote sample collection with sample stability at 2-8 degree C for 14 days: | Yes, No |
| Certifications | HPLC System is NGSP (National Glycohemoglobin Standardisation Program) Certified and traceable to IFCC reference method: | Yes, No |
| Certifications | Whether the product is US FDA certified: | Yes, No |
| Certifications | Whether the product is CE European certified: | Yes, No |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | POCT SERVICES Under PMA | Make : Bio-Rad Model : VARIANT II Hemoglobin Testing System 270-2000 | 20-03-2026 14:46:00 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | POCT SERVICES Under PMA | Item Categories : High Performance Liquid Chromatography (HPLC) System |