TenderDekho Logo
Closed GEM

Tender Notice for Supply,Installation Testing and Commissioning,Additional copper refrigerant Pipe and additional cab in KOLKATA, WEST BENGAL

Bid Publish Date

10-Aug-2026, 2:58 pm

Bid End Date

24-Aug-2026, 3:00 pm

Value

₹2,66,915

Progress

Issue10-Aug-2026, 2:58 pm
AwardPending

A tender has been published for State Bank Of India (sbi) Supply, Installation Testing and Commissioning, Additional copper refrigerant Pipe and additional cable, Additional Drain Pipe, Outdoor Stand in KOLKATA, WEST BENGAL. Quantity: 54 by. Submission Deadline: 24-08-2026 15: 00: 00. Check eligibility and apply.

Authority & Contact

Office Name

Kolkata

Grievance Contact

[email protected]

Tender Data

Bid Details

Quantity

54

Category

Supply

Bid Type

Two Packet Bid

Bid Validity

90 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

No

Startup Exemption/Relaxation

No

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

6

OEM Avg. Turnover

8

Past Performance

80 %

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Supply , Installation Testing and Commissioning , Additional copper refrigerant Pipe and additional cable , Additional Drain Pipe , Outdoor Stand

Payment Timelines

Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)

Delivery Details

Max Delivery Days

15

Delivery Locations

1

Delivery Cities

Kolkata

Delivery Pincodes

700001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
TANMAYA MISHRA700001,LHO kolkata, 1 Strand Road, KolkataKolkataWest Bengal700001615-

Authority Records

MINISTRY OF FINANCEFINANCIAL SERVICES DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9732718.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Bill of Quantities (BOQ) 5 Items Sign in for GEM prices

#1

Supply

Supply of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100 percent of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. ISEER value must be minimum of 5.6.The AC must have 2026 manufacturing year The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only 1 TR with 5 Star BEE Rating AC Make,-Hitachi/Voltas/Bluestar/Daikin /LG/Panasonic.

6 set Delivery: 15 days
#2

Installation Testing and Commissioning

Installation Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100 percent of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. ISEER value must be minimum of 5.6.The AC must have 2026 manufacturing year The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only 1 TR with 5 Star BEE Rating AC Make,-Hitachi/Voltas/Bluestar/Daikin /LG/Panasonic.

6 set Delivery: 15 days
#3

Additional copper refrigerant Pipe and additional cable

Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1 TR HI - WALL SPLIT with addtional necessary cables.

18 mtr Delivery: 15 days
#4

Additional Drain Pipe

Supply and fixing of duly insulated 25mm UPVC additional drain pipe

18 mtr Delivery: 15 days
#5

Outdoor Stand

Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1 TR Hi-Wall Split AC.

6 set Delivery: 15 days

Categories 87

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Additional Doc 3 (Requested in ATC)

10

Additional Doc 4 (Requested in ATC)

11

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

12

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer