TenderDekho Logo
Active GEM

UPPCL Low Voltage MCCB Tender Lucknow Uttar Pradesh IS/IEC 60947 Part 2 2026

Bid Publish Date

25-Jul-2026, 5:39 pm

Bid End Date

04-Aug-2026, 6:00 pm

Value

₹18,000

Progress

Issue25-Jul-2026, 5:39 pm
AwardPending
Explore all 6 tabs to view complete tender details

Quantity

1

Bid Type

Single Packet Bid

Key Highlights

  • Brand/OEM requirements: Not explicitly stated; ensure MCCB vendors provide OEM authorization if required
  • Technical standards: IS/IEC 60947 (Part 2) conformity, IS 60947-2 compliance
  • Special clauses: quantity variation up to 25%, extended delivery period calculations with minimum 30 days
  • Eligibility: standard MCCB suppliers capable of meeting performance parameters (trip type, poles, voltage, breaking capacity, current)
  • Warranty/AMC: not specified in data; verify with supplier and document during submission
  • Penalties/LD: not specified in data; confirm if applicable in contract terms
  • Delivery: Lucknow, UP; delivery schedule linked to last date of original order with option-based extension
  • Submission readiness: prepare technical and compliance documents to demonstrate IS/IEC conformance

Categories 4

Tender Overview

The Uttar Pradesh Power Corporation Limited (UPPCL) invites bids for a Low Voltage MCCB with Thermal Magnetic/Electronic Trip Unit conforming to IS/IEC 60947 (Part 2), located in Lucknow, Uttar Pradesh 226001. Estimated value is ₹18,000. The scope centers on procuring MCCBs meeting the specified performance parameters under the Q3 category. A notable differentiator is the bidder’s ability to meet the IS/IEC 60947-2 (Part 2) specifications, ensuring compatibility with UP electrical distribution needs. The contract allows bid quantity adjustments up to 25%, across order placement and currency, with a calculated extension formula to manage delivery timelines.

Technical Specifications & Requirements

  • Product category: Low Voltage MCCB with Thermal Magnetic/Electronic Trip Unit
  • Standard conformance: IS/IEC 60947 (Part 2) compliance
  • Performance parameters (listed):
    • Trip Unit Type
    • Number of Poles
    • Rated Voltage (in volt)
    • Rated Short Circuit Breaking Capacity (in kA)
    • Rated Current (in Ampere)
  • Key expectations: exact values for trip unit type, pole count, rated voltage, breaking capacity, and current must be provided by bidders; ensure products are compatible with UP distribution requirements.
  • Quality/Approval: comply with IS/IEC 60947-2 (Part 2) requirements; ensure authenticity of certification where applicable.

Terms, Conditions & Eligibility

  • Quantity variation right: Purchaser may increase/decrease quantity up to 25% of bid/contract quantity.
  • Delivery timeline handling: delivery period calculations based on original and extended periods with a minimum of 30 days; extended time may apply during option exercise.
  • Delivery terms: delivery shall commence from the last date of the original delivery order; extended delivery time follows the stated formula.
  • Bidder compliance: bidders must comply with the option clause and associated delivery logic; ensure readiness for potential changes in order quantity.

Key Specifications

  • Product: Low Voltage MCCB with Thermal Magnetic/Electronic Trip Unit

  • Conformance: IS/IEC 60947 (Part 2) certified

  • Category: Performance Parameters including Trip Unit Type, Number of Poles, Rated Voltage, Rated Short Circuit Breaking Capacity, Rated Current

Terms & Conditions

  • 25% quantity variation allowed at contract placement and during currency

  • Delivery period based on last date of original order with minimum 30 days extension rule

  • IS/IEC 60947 (Part 2) compliance required for all MCCBs

Important Clauses

Payment Terms

Not specified in provided data; verify during bid submission and contract finalisation

Delivery Schedule

Delivery begins from the last date of the original delivery order; extended time calculated as (increased quantity ÷ original quantity) × original delivery period, minimum 30 days

Penalties/Liquidated Damages

Not specified in provided data; confirm LD provisions in final contract

Bidder Eligibility

  • Experience in supplying MCCBs or similar protective devices

  • Capability to meet IS/IEC 60947 (Part 2) standards

  • Financial stability to handle contract variations up to 25%

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Low Voltage MCCB with Thermal Magnetic/Electronic Trip Unit Conforming To IS/IEC 60947 (Part 2) (Q3)

Payment Timelines

Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)

Delivery Details

Max Delivery Days

45

Delivery Locations

1

Delivery Cities

Lucknow

Delivery Pincodes

226010

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Bhanu Prakash Tiwari226010,ELECTRICITY 400KV SS DIVISION SAROJINI NAGAR LUCKNOWLucknowUttar Pradesh226010145-

Authority Records

ENERGY DEPARTMENTUTTAR PRADESH POWER CORPORATION LIMITED

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9617591.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Performance Parameters Trip Unit Type Electronic / Microprocessor Based
Performance Parameters Number of Poles 4
Performance Parameters Rated Voltage (in volt) 415V AC
Performance Parameters Rated Short Circuit Breaking Capacity (in kA) 25
Performance Parameters Rated Current (in Ampere) 100

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

GST registration certificate

2

Permanent Account Number (PAN) card

3

Experience certificates for similar MCCB supply

4

Financial statements / solvency documents

5

EMD submission proof (if applicable in terms, else clarify)

6

Technical bid documents showing IS/IEC 60947 (Part 2) compliance

7

OEM authorization letters (if required by UP Power Corporation Limited)

8

Product specifications and test reports to prove performance parameters

Frequently Asked Questions

Key insights about UTTAR PRADESH tender market

How to bid for MCCB tender in Lucknow with IS/IEC 60947 Part 2 compliance?

Bidders must provide IS/IEC 60947 (Part 2) compliant Low Voltage MCCBs with Trip Unit details, poles, voltage, current, and breaking capacity. Include OEM authorizations, GST, PAN, financials, and technical reports. The bid allows up to 25% quantity variation and requires delivery aligned to the original order plus extension rules.

What documents are required for UPPCL MCCB bid submission in Uttar Pradesh 2026?

Required documents include GST registration, PAN, experience certificates for MCCBs or similar devices, financial statements, EMD proof, technical bid showing IS/IEC 60947 (Part 2) conformance, OEM authorization letters if needed, and product test reports proving performance parameters.

Which IS/IEC standard must MCCBs meet for UPPCL procurement?

MCCBs must conform to IS/IEC 60947 (Part 2) with trip units suitable for each protection scheme. Bidders should provide documentation proving compliance and test results aligning with IS/IEC 60947-2 requirements to pass technical evaluation.

What is the delivery clause for quantity variation in UPPCL MCCB tender?

The purchaser may increase/decrease quantity up to 25% of bid/contract quantity at placement and during currency. Delivery period is calculated from the last date of the original delivery order, with a minimum 30 days extension if necessary.

What are the essential performance parameters requested for MCCBs in this tender?

Key parameters include Trip Unit Type, Number of Poles, Rated Voltage, Rated Short Circuit Breaking Capacity (kA), and Rated Current (A). Bidders must specify exact values for each parameter in the technical bid and demonstrate IS/IEC 60947-2 compliance.

What is the estimated value and location for this UP tender?

Estimated value is ₹18,000 for procurement, located in Lucknow, Uttar Pradesh. Bidders should align pricing, delivery, and compliance to UP distribution requirements under the energy department guidelines.

What testing or certification evidence is required for MCCB submissions?

Provide IS/IEC 60947-2 test reports, along with any OEM certifications and applicable quality certificates. Ensure documentation demonstrates conformance to performance parameters and that the product is suitable for installation in UP electrical distribution networks.