Visual Inspection,Rebound Hammer Test,UPV Test,Compressive strength,Half cell potentiometer test
Indian Army
Bid Publish Date
13-Nov-2025, 11:44 am
Bid End Date
04-Dec-2025, 12:00 pm
Bid Opening Date
04-Dec-2025, 12:30 pm
EMD
₹25,000
Value
₹8,41,930
Location
Progress
Quantity
258
Category
visual inspection and photography
Bid Type
Two Packet Bid
A tender has been published for Indian Army visual inspection and photography, Ultrasonic pulse valocity test, Rebound hammer test, Core test, Reinforcement mapping test, Chemical test, Half cell potential test, Carbonation test, Present status of structure, Recommendation for structure repairs and technical specification in SOUTH ANDAMAN, ANDAMAN & NICOBAR. Quantity: 258 by. Submission Deadline: 04-12-2025 12: 00: 00. Check eligibility and apply.
Indian Army
Indian Army
WEST KAMENG, ARUNACHAL PRADESH
Indian Navy
SOUTH ANDAMAN, ANDAMAN & NICOBAR
Indian Air Force
GWALIOR, MADHYA PRADESH
Indian Air Force
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | visual inspection and photography | M&L for visual inspection and photography performing a visual survey of the building and recording/ mapping in drawing to assess extent of spalled concrete, cracked concrete, honey combing, reinforcement corrosion, delapitated concrete etc. taking photographs to collect evidence of damage to structure complete all as specified and directed. Note (i) The scale of drawing map will be approved by GE. (ii) Photographs (numbers of photograph also) and map prepared and submitted to the entire satisfaction of GE. | 1 | each job | bsohaddoportb@1 | 90 |
| 2 | Ultrasonic pulse valocity test | M&L for ultrasonic pulse valocity test for RCC structure in accordance with IS 13311 Part-I 1992 by portable ultrasoic non destructive digital test equipment including chipping out plaster at strategic locations and submit report with noticed damages and recommended correction methodology complete all as specified and directed. | 60 | each job | bsohaddoportb@1 | 90 |
| 3 | Rebound hammer test | M&L for rebound hammer test in accordance with IS 516 Part-5 2018 SECTION 4 by portable rebound hammer equipment at strategic locations and submit the test results complete all as specified and directed. | 60 | each job | bsohaddoportb@1 | 90 |
| 4 | Core test | M&L for core test by core cutting and compression test for RCC structure in accordance with IS 516 on RCC members. 70mm core cutting in reinforcement concrete, core filling by specialized epoxy material/ micro concrete with bond coat at strategic locations and submit the assesment report complete all as specified and directed. | 25 | each job | bsohaddoportb@1 | 90 |
| 5 | Reinforcement mapping test | M&L for reinforcement mapping test on RCC members to assess covers, spacing of bars including approximate diameter at strategic locations and submit the report complete all as specified and directed. | 25 | each job | bsohaddoportb@1 | 90 |
| 6 | Chemical test | M&L for chemical test for RCC structure in accordance with IS 456 2000 using ready made kits and re-agents, sample collected will be from half cell/ carbonation powder at strategic locations complete all as specified and directed as under (i) Determination of PH value. (ii) Determination of water soluble sulphates. (iii) Determination of water soluble chlorides contents | 25 | each job | bsohaddoportb@1 | 90 |
| 7 | Half cell potential test | M&L for half cell potential test for RCC structure in accordance with IS 516 Part-5 2018 SECTION-2, half cell potential to assess the probability of corrosion of reinforcement at strategic locations complete all as specified and directed. | 30 | each job | bsohaddoportb@1 | 90 |
| 8 | Carbonation test | M&L for carbonation test for RCC structure in accordance with IS 516 Part-5 2018 SECTION-3, corbonatin test measure extent of carbonation from the concrete surface at strategic locations complete all as specified and directed. | 30 | each job | bsohaddoportb@1 | 90 |
| 9 | Present status of structure | M&L to check & confirm present status of structure on basis on NDT results & visual inspection complete all as specified and directed. | 1 | each job | bsohaddoportb@1 | 90 |
| 10 | Recommendation for structure repairs and technical specification | M&L to provide recommendation for structure repairs and technical specification, preparing bill of quantities for the repair etc complete all as specified and directed. | 1 | each job | bsohaddoportb@1 | 90 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Access all tender documents at no cost
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS