Minorities Welfare Department Bihar Repair, Maintenance & Installation Tender Darbhanga 2025 – Plant/Systems/Equipment
Minorities Welfare Department
DARBHANGA, BIHAR
Bid Publish Date
12-Jan-2026, 8:51 pm
Bid End Date
23-Jan-2026, 7:00 pm
EMD
₹4,20,000
Location
Progress
Quantity
10
Bid Type
Two Packet Bid
Public procurement opportunity for N/a Drinking Water ATM / Water Vending Machine (Version 2) (Q3) in AZAMGARH, UTTAR PRADESH. Quantity: 10 issued by. Submission Deadline: 23-01-2026 19: 00: 00. View full details and respond.
Minorities Welfare Department
DARBHANGA, BIHAR
Border Security Force (bsf)
NAGAUR, RAJASTHAN
Border Security Force (bsf)
NAGAUR, RAJASTHAN
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
GORAKHPUR, UTTAR PRADESH
Minorities Welfare Department
DARBHANGA, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Coin / Card Acceptor / Quantity of Dispensing Water | Number of Dispensing points | 3, 4, 5, 6 Or higher |
| Coin / Card Acceptor / Quantity of Dispensing Water | Water Dispensing using coin acceptor | Yes |
| Coin / Card Acceptor / Quantity of Dispensing Water | Coins accepted for payment | Re.1, Rs. 2, Rs. 5, Rs.10, Rs. 20 |
| Coin / Card Acceptor / Quantity of Dispensing Water | Water Dispensing using RFID/NFC card | No |
| Coin / Card Acceptor / Quantity of Dispensing Water | Mobile Wallet accepted for payment | No |
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Purification Capacity of Water ATM (LPH) | 1000, 2000 Or higher |
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Type of Operation | Semi-Automatic, Automatic with Multi-Processor Integrated Control System and remotely conrolled web based Server system Or higher |
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Water Source | Municipal Tap water |
| TECHNOLOGY | Technology | Reverse Osmosis (RO) |
| TECHNOLOGY | Anti scalant dosing pump | Yes |
| TECHNOLOGY | pH Correction Dosing Pump | No |
| CONSTRUCTIONAL | Raw water Storage capacity (Indicate '0' for direct connection to continuous Tap Water source) | 3000, 5000, 8000, 10000 Or higher |
| CONSTRUCTIONAL | Raw water Storage Tank Material of Construction | HDPE |
| CONSTRUCTIONAL | Location of the Raw Water Storage Tank | Inside the ATM Enclosure |
| CONSTRUCTIONAL | Treated water Storage capacity | 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000 Or higher |
| CONSTRUCTIONAL | Treated water Storage Tank Material of Construction | Stainless Steel 316 Gr, Stainless Steel 304 Gr, HDPE Or higher |
| CONSTRUCTIONAL | Equipped with an in-built chiller unit for providing continuous cold water of temperature around 15 degree Celcius | Yes |
| CONSTRUCTIONAL | In-built Chiller Tank Capacity (Liter) | 151-200, 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000 Or higher |
| CONSTRUCTIONAL | Chiller Tank Material of Construction | Stainless Steel 316 Gr, Stainless Steel 304 Gr Or higher |
| CONSTRUCTIONAL | Number of Filtration steps | 5 |
| CONSTRUCTIONAL | Provided with suitable vending place for filling container of 20 liters capacity | No |
| DISPLAY | Display of water purity parameters | Yes, No |
| DISPLAY | Display Type | LED, LCD, TFT, NA Or higher |
| DISPLAY | Backlit Display | Yes, No |
| DISPLAY | Touch Screen Display | Yes, No |
| DISPLAY | Display Size (Characters x Lines) | 4 x 2 (4 Ch x 2 lines), 8 x 2 (8 Ch x 2 lines), 16 x 2 (16 Ch x 2 lines), 20 x 2 (20 Ch x 2 lines), 7" Tablet, NA |
| DISPLAY | Display of oulet water TDS level | Yes, No |
| DISPLAY | Display of outlet water pH level | Yes, No |
| DISPLAY | Display of outlet water Temperature | Yes, No |
| Inlet / Feed Pump to feed water from raw water storage tank to filter | Inlet / Feed Pump Type | Horizontal Centrifugal |
| Inlet / Feed Pump to feed water from raw water storage tank to filter | Number of Inlet / Feed Pumps | 1 |
| Multi Media Filter Vessels for First stage filtration for suspended particles | Material Of Construction for Multi Media Filter Vessels | FRP, Steel Or higher |
| Multi Media Filter Vessels for First stage filtration for suspended particles | Number of Multi Media Filter Vessels | 2 Or higher |
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Type of Multi-Port Valve | Manual |
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Multi-Port Valve Material of Construction | PP |
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Number of Multi-Port Valves | 2 |
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Type of Anti scalent Dosing Pump | Electronic diaphragm |
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Material Of Construction for Anti scalent Dosing Pump | PP |
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Number of Anti scalent Dosing Pumps | 1 |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Type of pH Correction Pump | NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Material Of Construction for pH Correction Dosing Pump | NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Number of pH Correction Dosing Pumps | NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Dosing Tank Material of Construction | NA |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Type of High Pressure Pump | Vertical Centrifugal Pump |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Material Of Construction for High Pressure Pump | SS |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Number of High Pressure Pumps | 1, 2, 3 Or higher |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Low pressure switch for Protection of HP pump from burn-out | Yes |
| RO Pressure Vessel | Type of RO Pressure Vessel | Membrane housing mounted on skid - End port type |
| RO Pressure Vessel | Material Of Construction for RO Pressure Vessel | FRP |
| RO Pressure Vessel | Number of RO Pressure Vessels | 4 Or higher |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Material Of Construction for UV System | SS |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Number of UV Systems | 2 Or higher |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Number of UV Lights | 2, 3, 4, 5, 6 Or higher |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Total UV Power | 12 Watts |
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | CIP Tank | No |
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | CIP Tank Material of Construction | NA |
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | Number of CIP Tanks | NA Or higher |
| Power Source | Power Source | AC Power Supply |
| Power Source | Power Supply | 230 ±10 V AC |
| Power Source | Battery back-up time (Hours) | 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 Or higher |
| Water ATM - Enclosure | Structure | Rigid structure made of SS frame(3), Or higher |
| Water ATM - Enclosure | Thickness of the frame of structure (mm) | 2.5, 2 Or higher |
| Water ATM - Enclosure | Material of Construction of Side Panels of Water ATM | Stainless Steel Sheet, Galvanized Steel Sheet Or higher |
| Water ATM - Enclosure | Side Panel Sheet Thickness (mm) | 0.6, 0.8, 1, 1.2 Or higher |
| Water ATM - Enclosure | PUF insulation of Side Panels of Water ATM | With, Without Or higher |
| Water ATM - Enclosure | PUF insulation of the door of Water ATM | With, Without Or higher |
| Water ATM - Enclosure | Provision for in-built litter space | No |
| Water ATM - Enclosure | Covered area of treatment plant enclosure (Square Foot) | 30.1-40, 40.1-50, 50.1-60, 60.1-70, 70.1-80, 80.1-90, 90.1-100, 100.1-110, 110.1-120 Or higher |
| Water ATM - Enclosure | Shape of the Water ATM housing | Cubical |
| Water ATM - Enclosure | Top Canopy of the Water ATM housing | Sloped |
| Water ATM - Enclosure | Headroom for the Water ATM enclosure (Foot) | 7.1-8.0, 8.1-9.0, 9.1-10.0 Or higher |
| Water ATM - Enclosure | Floor area around the Water ATM enclosure covered with anti-skid tiles | Yes |
| Water ATM - Enclosure | Water ATM enclosure protected with enclosed MS grill / mesh | Yes |
| Installation & Commissioning / Warranty | Trial Run and Training provided (inclusive in the Scope of Supply) (Days) | 5, 10 Or higher |
| Installation & Commissioning / Warranty | Warranty for storage Tanks (Year) | 3, 4, 5 Or higher |
| Installation & Commissioning / Warranty | Warranty for electrical motors (Year) | 1, 2, 3 Or higher |
| Installation & Commissioning / Warranty | Warranty for the filters (Year) | 1, 2, 3 Or higher |
| Installation & Commissioning / Warranty | Warranty for the system (Year) | 1, 2, 3 Or higher |
| Test Reports | Availability of Test Report from Central Govt /NABL/ILAC accredited lab to prove confirmity to specification | Yes |
| Test Reports | All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Rural Development Department
📍 SAMASTIPUR, BIHAR
Indo Tibetan Border Police (itbp)
📍 SHIVPURI, MADHYA PRADESH
Chhattisgarh Swami Vivekananda Technical University (csvtu)
📍 DURG, CHHATTISGARH
Uttar Pradesh Power Corporation Limited (uppcl)
📍 LUCKNOW, UTTAR PRADESH
Indian Army
📍 SRINAGAR, JAMMU & KASHMIR
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS