Master Server,Stub Server,Data Rack with accessories, Rack PDU, 3kVA UPS, EMS, In rack AC, Installa
Indian Coast Guard
GANDHI NAGAR, GUJARAT
Progress
RAQuantity
842
Category
S-1-44 OU Rack
Bid Type
Two Packet Bid
Centre For Development Of Advanced Computing (c-dac) has released a public tender for S-1-44 OU Rack, S-1-Open rack power shelf, S-1-Power supply, S-1-OTHER, S-1-Install, S-2-44 OU Rack, S-2-Open rack power shelf, S-2-Power supply, S-2-OTHER, S-2- Install, S-3-44 OU Rack, S-3-Open rack power shelf, S-3- Power supply, S-3-OTHER, S-3-Install, S-4-44 OU Rack, S- 4-Open rack power shelf, S-4-Power supply, S-4-OTHER, S-4-Install, S-5-44 OU Rack, S-5-Open rack power shelf, S- 5-Power supply, S-5-OTHER, S-5-Install, S-6-44 OU Rack, S-6-Open rack power shelf, S-6-Power supply, S-6-Racks, S-6-OTHER, S-6-Install, S-7-44 OU Rack, S-7-Open rack power shelf, S-7-Power supply, S-7-OTHER, S-7-Install in PUNE, MAHARASHTRA. Quantity: 842. Submission Deadline: 28-07-2025 18: 00: 00. Download documents and apply online.
Main Document
BOQ
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Coast Guard
GANDHI NAGAR, GUJARAT
Gauhati High Court Aizawl Bench
AIZAWL, MIZORAM
Indian Army
LEH, JAMMU & KASHMIR
Indian Army
JORHAT, ASSAM
Archaeological Survey Of India (asi)
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | S-1-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars | 11 | nos | vinayaks | 84 |
| 2 | S-1-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring | 33 | nos | vinayaks | 84 |
| 3 | S-1-Power supply | Open Rack V3 HPR Power Supply Unit | 198 | nos | vinayaks | 84 |
| 4 | S-1-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 5 | S-1-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
| 6 | S-2-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars, PDU, IEC Socket, reducer bracket and CU Cable, Server mounting bracket and other accessories | 7 | nos | vinayaks | 84 |
| 7 | S-2-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring Interface PMI) Module | 21 | nos | vinayaks | 84 |
| 8 | S-2-Power supply | Open Rack V3 HPR Power Supply Unit | 126 | nos | vinayaks | 84 |
| 9 | S-2-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 10 | S-2-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
| 11 | S-3-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars, PDU, IEC Socket , reducer bracket and CU Cable, Server mounting bracket and other accessories | 10 | nos | vinayaks | 84 |
| 12 | S-3-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring Interface PMI | 30 | nos | vinayaks | 84 |
| 13 | S-3-Power supply | Open Rack V3 HPR Power Supply Unit | 180 | nos | vinayaks | 84 |
| 14 | S-3-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 15 | S-3-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
| 16 | S-4-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars, PDU, IEC Socket, reducer bracket and CU Cable, Server mounting bracket and other accessories | 3 | nos | vinayaks | 84 |
| 17 | S-4-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring Interface PMI | 6 | nos | vinayaks | 84 |
| 18 | S-4-Power supply | Open Rack V3 HPR Power Supply Unit | 36 | nos | vinayaks | 84 |
| 19 | S-4-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 20 | S-4-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
| 21 | S-5-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars, PDU, IEC Socket, reducer bracket and CU Cable, Server mounting bracket and other accessories | 4 | nos | vinayaks | 84 |
| 22 | S-5-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring Interface PMI | 8 | nos | vinayaks | 84 |
| 23 | S-5-Power supply | Open Rack V3 HPR Power Supply Unit | 48 | nos | vinayaks | 84 |
| 24 | S-5-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 25 | S-5-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
| 26 | S-6-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars, PDU, IEC Socket, reducer bracket and CU Cable, Server mounting bracket and other accessories | 3 | nos | vinayaks | 84 |
| 27 | S-6-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring Interface PMI | 6 | nos | vinayaks | 84 |
| 28 | S-6-Power supply | Open Rack V3 HPR Power Supply Unit | 36 | nos | vinayaks | 84 |
| 29 | S-6-Racks | Standard 42U Racks with 800mm x 1300mm with 2x 32A 3-phase PDU each with 18 IEC-13 sockets and 6 -IEC19 sockets | 2 | nos | vinayaks | 84 |
| 30 | S-6-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 31 | S-6-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
| 32 | S-7-44 OU Rack | 44 OU Rack along with ORV3 Bus Bars, PDU, IEC Socket, reducer bracket and CU Cable, Server mounting bracket and other accessories | 4 | nos | vinayaks | 84 |
| 33 | S-7-Open rack power shelf | Open Rack V3 HPR Power Shelf including Open Rack V3 HPR Power Monitoring Interface PMI | 8 | nos | vinayaks | 84 |
| 34 | S-7-Power supply | Open Rack V3 HPR Power Supply Unit | 48 | nos | vinayaks | 84 |
| 35 | S-7-OTHER | Any other items/components etc. required to complete the solutions including rack PDU, Cables, male female IEC socket etc. | 1 | nos | vinayaks | 84 |
| 36 | S-7-Install | Installation, Commissioning, Testing & other charges, if any | 1 | nos | vinayaks | 84 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
28-Jul-2025, 6:00 pm
Opening Date
28-Jul-2025, 6:30 pm
Extended Deadline
28-Jul-2025, 3:00 pm
Opening Date
28-Jul-2025, 3:30 pm
Start
14-Sep-2025, 10:00 am
End
16-Sep-2025, 10:00 am
Duration: 48 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | NIRVAA SOLUTIONS PRIVATE LIMITED Under PMA | - | 28-07-2025 17:02:49 | Qualified |
| 2 | POWER TECHNICS INFOSOLUTIONS PRIVATE LIMITED Under PMA | - | 28-07-2025 14:53:28 | Qualified |
| 3 | TECH INDIA ELECTROSOLUTIONS PRIVATE LIMITED Under PMA | - | 28-07-2025 17:44:12 | Qualified |
| 4 | VERTIV ENERGY PRIVATE LIMITED Under PMA | - | 28-07-2025 13:49:51 | Qualified |
These are the final prices after the reverse auction event. Prices may be lower than initial bids.
| Rank | Seller | Final Price | Item |
|---|---|---|---|
| L1 | TECH INDIA ELECTROSOLUTIONS PRIVATE LIMITED Under PMA Winner | ₹9,40,14,000 | Item Categories : S-1-44 OU Rack,S-1-Open rack power shelf,S-1-Power supply,S-1-OTHER,S-1-Install,S-2-44 OU Rack,S-2- |
| L2 | POWER TECHNICS INFOSOLUTIONS PRIVATE LIMITED Under PMA | ₹9,41,54,650 | Item Categories : S-1-44 OU Rack,S-1-Open rack power shelf,S-1-Power supply,S-1-OTHER,S-1-Install,S-2-44 OU Rack,S-2- |
| L3 | VERTIV ENERGY PRIVATE LIMITED Under PMA | ₹9,66,17,600 | Item Categories : S-1-44 OU Rack,S-1-Open rack power shelf,S-1-Power supply,S-1-OTHER,S-1-Install,S-2-44 OU Rack,S-2- |
🎉 L1 Winner
TECH INDIA ELECTROSOLUTIONS PRIVATE LIMITED Under PMA
Final Price: ₹9,40,14,000
Please sign in or create an account to view contract details and download result documents.
Key insights about MAHARASHTRA tender market
The eligibility requirements for participating in this tender include being a registered legal entity with the capability to deliver the specified products. Bidders must have prior experience in similar projects and demonstrate financial stability through relevant documents. Compliance with local regulations is also essential for acceptance.
Bidders are expected to provide certain required certificates that demonstrate their legal status as an entity, proof of prior project experience, financial statements, and any certifications related to quality standards applicable to the supply of electronic racks.
To register for participation in this tender, potential bidders must follow the outlined registration process through the official tender portal. Required documentation must be submitted along with the registration to ensure eligibility for submission.
Submissions must be made in specified accepted document formats as indicated in the tender guidelines. Typically, these formats may include PDF, DOC, XLS, and other standard file types that ensure compatibility and accessibility during evaluation.
The tender includes special provisions for Micro, Small, and Medium Enterprises (MSEs) that encourage their participation by providing benefits such as relaxed eligibility criteria, potential price preferences, and incentives under the procurement policies designed to support their development. Compliance with 'Make in India' policies is also referenced to enhance local procurement and production capabilities.
Sign up now to access all documents
Main Document
BOQ
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS