Progress
Quantity
1037
Category
Supply, Installation, Testing and Commissioning of wall type Split air conditioners
Bid Type
Two Packet Bid
National Institute Of Fashion Technology (nift) Head Office New Delhi invites bids for Supply, Installation, Testing and Commissioning of wall type Split air conditioners, Supply, Installation, Testing and Commissioning 5 KVA Automatic voltage. , Supply, Installation, Testing and Commissioning of soft drawn copper piping for refrigerant, Supply and Fixing of PVC hard drawn condensate water drain piping of 25mm dia. , Supply and Fixing of Electrical wire 4 core x 2. 5 sq. mm, Supply and Fixing of M S Stand for AC out door unit, Dismantling of AC and Shifting of units at the specified place in BANGALORE, KARNATAKA. Quantity: 1037. Submission Deadline: 02-12-2025 20: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Supply, Installation, Testing and Commissioning of wall type Split air conditioners , Supply, Installation, Testing and Commissioning 5 KVA Automatic voltage. , Supply, Installation, Testing and Commissioning of soft drawn copper piping for refrigerant , Supply and Fixing of PVC hard drawn condensate water drain piping of 25mm dia. , Supply and Fixing of Electrical wire 4 core x 2.5 sq. mm , Supply and Fixing of M S Stand for AC out door unit , Dismantling of AC and Shifting of units at the specified place
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Supply, Installation, Testing and Commissioning of wall type Split air conditioners
Material of Condenser & Evaporator copper coils, Cooling capacity - Minimum 2.0 Ton, Latest BEE 5-star, Eco-friendly refrigerants, Cooling Only, Inverter Technology_Minimum length of copper pipe 3 Mtrs and suitable connecting electrical cable
Supply, Installation, Testing and Commissioning 5 KVA Automatic voltage.
Power Rating- 5 KVA,. Input voltage range Single Phase Sine wave (160V-260V), Output voltage range Single Phase Sine Wave (195 V to 245 V), Material of winding 100% Copper, Minimum Warranty period 3 Years
Supply, Installation, Testing and Commissioning of soft drawn copper piping for refrigerant
copper piping for refrigerant with NBR tubular thermal insulation (9mm thick), covering with PVC tape, between indoor to outdoor unit of split AC suitable for 1.5 ton & 2.0-ton Split AC and as per manufacturer recommendation for piping and as per direction of engineer -in-charge.
Supply and Fixing of PVC hard drawn condensate water drain piping of 25mm dia.
water drain piping of 25mm dia. with necessary hardware fittings like clamps, bend and joints etc. for fixing of piping, as per direction of engineer -in-charge.
Supply and Fixing of Electrical wire 4 core x 2.5 sq. mm
Electrical wire 4 core x 2.5 sq. mm for connection between indoor to outdoor (Round Triple layer PVC Insulated Flexible Copper wire as per IEC and ISI mark) as per direction of engineer -in-charge.
Supply and Fixing of M S Stand for AC out door unit
M S Stand including Hardware supply for placing of outdoor unit (wall / floor type) as per requirement and direction of engineer -in charge.
Dismantling of AC and Shifting of units at the specified place
Dismantling of 2/ 1.5 ton AC and Shifting of units at the specified place as per direction of engineer -in-charge.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of wall type Split air conditioners | Material of Condenser & Evaporator copper coils, Cooling capacity - Minimum 2.0 Ton, Latest BEE 5-star, Eco-friendly refrigerants, Cooling Only, Inverter Technology_Minimum length of copper pipe 3 Mtrs and suitable connecting electrical cable | 40 | units | purchase blr | 30 | |
| 2 | Supply, Installation, Testing and Commissioning 5 KVA Automatic voltage. | Power Rating- 5 KVA,. Input voltage range Single Phase Sine wave (160V-260V), Output voltage range Single Phase Sine Wave (195 V to 245 V), Material of winding 100% Copper, Minimum Warranty period 3 Years | 50 | units | purchase blr | 30 | |
| 3 | Supply, Installation, Testing and Commissioning of soft drawn copper piping for refrigerant | copper piping for refrigerant with NBR tubular thermal insulation (9mm thick), covering with PVC tape, between indoor to outdoor unit of split AC suitable for 1.5 ton & 2.0-ton Split AC and as per manufacturer recommendation for piping and as per direction of engineer -in-charge. | 200 | mts | purchase blr | 30 | |
| 4 | Supply and Fixing of PVC hard drawn condensate water drain piping of 25mm dia. | water drain piping of 25mm dia. with necessary hardware fittings like clamps, bend and joints etc. for fixing of piping, as per direction of engineer -in-charge. | 500 | mts | purchase blr | 30 | |
| 5 | Supply and Fixing of Electrical wire 4 core x 2.5 sq. mm | Electrical wire 4 core x 2.5 sq. mm for connection between indoor to outdoor (Round Triple layer PVC Insulated Flexible Copper wire as per IEC and ISI mark) as per direction of engineer -in-charge. | 200 | mts | purchase blr | 30 | |
| 6 | Supply and Fixing of M S Stand for AC out door unit | M S Stand including Hardware supply for placing of outdoor unit (wall / floor type) as per requirement and direction of engineer -in charge. | 40 | units | purchase blr | 30 | |
| 7 | Dismantling of AC and Shifting of units at the specified place | Dismantling of 2/ 1.5 ton AC and Shifting of units at the specified place as per direction of engineer -in-charge. | 7 | units | purchase blr | 30 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | BATTERY POWER SOLUTIONS Under PMA | - | 02-12-2025 17:37:02 | |
| 2 | BHAGYA LAXMI INTERNATIONAL Under PMA | - | 02-12-2025 11:20:33 | |
| 3 | COMCAT Under PMA | - | 01-12-2025 18:43:14 | |
| 4 | COMFORTS MARKETING Under PMA | - | 02-12-2025 11:44:06 | |
| 5 | COMPETENT ENGINEERS Under PMA | - | 27-11-2025 14:08:51 | |
| 6 | CREATIVE ENGINEERS Under PMA | - | 27-11-2025 16:18:49 | |
| 7 | EVANTAGE TECH SOLUTIONS Under PMA | - | 02-12-2025 19:22:42 | |
| 8 | FIRST INTERIORS Under PMA | - | 02-12-2025 18:16:06 | |
| 9 | M/S BANERJEE & BANERJEE EQUIPMENTS Under PMA | - | 02-12-2025 19:53:08 | |
| 10 | MATRIX EXPORTS Under PMA | - | 02-12-2025 18:29:20 | |
| 11 | Sri Tirupati Electricals Under PMA | - | 16-11-2025 15:09:16 | |
| 12 | Sri Venugopalaswamy Electricals Under PMA | - | 16-11-2025 16:00:26 | |
| 13 | SURAJ SALES CORPORATION Under PMA | - | 02-12-2025 14:47:39 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | BATTERY POWER SOLUTIONS(MII) Under PMA | Item Categories : Supply, Installation, Testing and Commissioning of wall type Split air conditioners,Supply, Install | |
| L2 | MATRIX EXPORTS (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : Supply, Installation, Testing and Commissioning of wall type Split air conditioners,Supply, Install | |
| L3 | COMFORTS MARKETING (MII) Under PMA | Item Categories : Supply, Installation, Testing and Commissioning of wall type Split air conditioners,Supply, Install | |
| L4 | FIRST INTERIORS (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : Supply, Installation, Testing and Commissioning of wall type Split air conditioners,Supply, Install | |
| L5 | Sri Venugopalaswamy Electricals (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : Supply, Installation, Testing and Commissioning of wall type Split air conditioners,Supply, Install | |
| L6 | Sri Tirupati Electricals (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : Supply, Installation, Testing and Commissioning of wall type Split air conditioners,Supply, Install |
Please sign in or create an account to view contract details and download result documents.
Sign up now to access all documents
Main Document
BOQ
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS