Recirculating chiller
Directorate Of Purchase And Stores
Indian Space Research Organization announces a tender for Recirculating chiller (Q3) in BANGALORE, KARNATAKA. Quantity: 1. Submission Deadline: 21-01-2026 10: 00: 00. Last date to apply is approaching fast!
Directorate Of Purchase And Stores
Satara District Panchayats
SATARA, MAHARASHTRA
Pune District Panchayats
PUNE, MAHARASHTRA
Osmanabad District Panchayats
OSMANABAD, MAHARASHTRA
Iter India Ipr
AHMEDABAD, GUJARAT
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Certification and Standard | Conformity to Standard | SEMI-S2-0200 |
| Product info | Type | Bench top type model |
| Product info | Temperature Controller | Digital |
| Constructional Parameter | Type of Pump | Centrifugal pump |
| Performance Parameter | Tank capacity/Reservoir Volume | 40.0 |
| Performance Parameter | Heater Capacity (Kw) (If not applicable please select 0) | 0.0 |
| Performance Parameter | Cooling capacity at 10 degree Celsius(watt) | 10500.0 |
| Performance Parameter | Pressure (Bar) | 3.0 |
| Performance Parameter | Cooling Capacity frequency | 50.0 |
| Performance Parameter | Refrigerant | R407C |
| Performance Parameter | Pumping Capacity,lpm | 50 |
| Performance Parameter | Pumping Capacity frequency | 50.0 |
| Electrical Requirement | Operating Voltage | 415.0 |
| Electrical Requirement | Number of Phase | 3 |
| Electrical Requirement | Electric Current(Amphere) | 14 |
| Electrical Requirement | Frequency | 50.0 |
| Electrical Requirement | Heater Voltage requirement (If not applicable please select 0) | 0 |
| Environmental Condition | Standard Temperature Range | 15.0 |
| Environmental Condition | Temperature Stability,degree Celsius | 1.0 |
| Dimension and Size | Depth | 100.0 |
| Dimension and Size | Width | 65.0 |
| Dimension and Size | Height | 150.0 |
| Dimension and Size | Weight | 280.0 |
| Technical specification | Pump protection due to low level of coolant | Yes |
| Additional Parameter | drain | 1/2 inch female NPT |
| Additional Parameter | inlet/outlet | 1 inch female NPT |
| Additional Parameter | Deionization filter | No |
| Shelf Life | Warranty | 1.0 - 3.0 Or higher |
| Test Report | Test Report To Be Submitted To The Buyer On Demand | Yes |
| Test Report | Availability of Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification | No |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS