Progress
Public procurement opportunity for Bharat Sanchar Nigam Limited Portal(bsnl) SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel, Augmentation in the all existing AFD system, SITC of photo electric smoke detector, SITC of ionization smoke detector, SITC of electropneumatic type dual action heat detector, SITC of electronic hooter or conventional hooter with LMT, SITC of Response indicator for existing panel of visual indication, SITC of Manual call point, Supplying and fixing of 20mm size of steel conduit, Supplying and fixing of 25mm size steel conduit size, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 2x1. 5Sqmm, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 3x1. 5Sqmm, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 4x1. 5Sqmm, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 5x1. 5Sqmm, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 6x1. 5Sqmm, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 7x1. 5Sqmm, Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 8x1. 5Sqmm in JAIPUR, RAJASTHAN. Quantity: 183 issued by. Submission Deadline: 21-10-2026 15: 00: 00. View full details and respond.
Quantity
183
Category
SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
3 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
1
OEM Avg. Turnover
1
Past Performance
80 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel , Augmentation in the all existing AFD system , SITC of photo electric smoke detector , SITC of ionization smoke detector , SITC of electropneumatic type dual action heat detector , SITC of electronic hooter or conventional hooter with LMT , SITC of Response indicator for existing panel of visual indication , SITC of Manual call point , Supplying and fixing of 20mm size of steel conduit , Supplying and fixing of 25mm size steel conduit size , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 2x1.5Sqmm , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 3x1.5Sqmm , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 4x1.5Sqmm , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 5x1.5Sqmm , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 6x1.5Sqmm , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 7x1.5Sqmm , Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 8x1.5Sqmm
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
12
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Jaipur
Delivery Pincodes
302001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Satish Chand Jain | 302001,Q No. R2 & R4 Type 4, P & T Colony C-Scheme, Jaipur | Jaipur | Rajasthan | 302001 | 1 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel
SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel suitable for wall mounting type, fabricated out of CRCA sheet incorporating to accommodate the following items duly powder coated in approved colour with louvers for ventilation, audio and visual indication for each zone for fire alarm and public address system, with Power Supply and Battery Charger i/c 02 nos 12 V,28 AH Sealed maintenance free batteries with 45 Watt PA Amplifier suitable for operation on 230V AC/24V DC supply conforming to IEC268-3 complete with all accessories -1 No and Dynamic microphone with 3 Meter Lead-1 No., complete as per specification attached and all the feature accommodate in single wall mount double door with locking arrangement cabinet etc complete as required.
Augmentation in the all existing AFD system
Augmentation in the all existing AFD system for SITC new microprocessor based AFD panel in place of existing AFD Panel to panel i/c dismantling of existing all AFD panel, loose wire box and wiring and all associated item i/c providing and drawing additional wiring for charging circuit ,reconnection of all wiring , conduit /cable modification of loose wire Box , testing of complete afd system in entire building and replacement of faulty items etc. as required.
SITC of photo electric smoke detector
SITC of photo electric smoke detector( blinking LED type) with the sampling cage mounting base complete on the detector junction box incorporating a solid state L.E.D and a high speed light sensing chamber and other accessories etc. as per specification attached as reqd
SITC of ionization smoke detector
SITC of ionization smoke detector with sampling cage mounting base complete (blinking LED type)on detector junction box consisting a solid state L.E.D.with two ionization chamber containing amercium foil electronic circuits for contract, connection ,etc.complete as per specification attached.
SITC of electropneumatic type dual action heat detector
SITC of electropneumatic type dual action heat detector (blinking LED type) consisting of an air chamber, flexible matal diaphragm, phosphor bronze spring and moisture proof design, trouble free ventmounted on detector junction box with builtin L.E.D. and mounting base. The detector should be full proof design compact, reeged and uneffected of vibrations and work on dual action, connection etc. completed as per specification.
SITC of electronic hooter or conventional hooter with LMT
SITC of electronic hooter/ conventional hooter with LMT,capable for existing panel of public announcement as work as being used for fire and faultin fire alarm panel i/c connection etc. as reqd
SITC of Response indicator for existing panel of visual indication
SITC of Response indicator for existing panel of visual indication in MS box as work as being indicating used for fire and fault in fire alarm panel i/c connection etc. as reqd
SITC of Manual call point
SITC of Manual call point (MCP) in 16 SWG MS Box for visual indication having a push button & hammer with chain for as work as being indicating used for fire zone testing i/c connection etc. as reqd
Supplying and fixing of 20mm size of steel conduit
Supplying and fixing of 20mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25mm size steel conduit size
Supplying and fixing of 25mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 2x1.5Sqmm
Supplying and drawing 2x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 3x1.5Sqmm
Supplying and drawing 3x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 4x1.5Sqmm
Supplying and drawing 4x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 5x1.5Sqmm
Supplying and drawing 5x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 6x1.5Sqmm
Supplying and drawing 6x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 7x1.5Sqmm
Supplying and drawing 7x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 8x1.5Sqmm
Supplying and drawing 8x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel | SITC of 14 zone microprocessor based Automatic Fire Detection Main control panel suitable for wall mounting type, fabricated out of CRCA sheet incorporating to accommodate the following items duly powder coated in approved colour with louvers for ventilation, audio and visual indication for each zone for fire alarm and public address system, with Power Supply and Battery Charger i/c 02 nos 12 V,28 AH Sealed maintenance free batteries with 45 Watt PA Amplifier suitable for operation on 230V AC/24V DC supply conforming to IEC268-3 complete with all accessories -1 No and Dynamic microphone with 3 Meter Lead-1 No., complete as per specification attached and all the feature accommodate in single wall mount double door with locking arrangement cabinet etc complete as required. | 1 | each | satcj75@bsnl | 30 | |
| 2 | Augmentation in the all existing AFD system | Augmentation in the all existing AFD system for SITC new microprocessor based AFD panel in place of existing AFD Panel to panel i/c dismantling of existing all AFD panel, loose wire box and wiring and all associated item i/c providing and drawing additional wiring for charging circuit ,reconnection of all wiring , conduit /cable modification of loose wire Box , testing of complete afd system in entire building and replacement of faulty items etc. as required. | 1 | job | satcj75@bsnl | 30 | |
| 3 | SITC of photo electric smoke detector | SITC of photo electric smoke detector( blinking LED type) with the sampling cage mounting base complete on the detector junction box incorporating a solid state L.E.D and a high speed light sensing chamber and other accessories etc. as per specification attached as reqd | 34 | number | satcj75@bsnl | 30 | |
| 4 | SITC of ionization smoke detector | SITC of ionization smoke detector with sampling cage mounting base complete (blinking LED type)on detector junction box consisting a solid state L.E.D.with two ionization chamber containing amercium foil electronic circuits for contract, connection ,etc.complete as per specification attached. | 34 | number | satcj75@bsnl | 30 | |
| 5 | SITC of electropneumatic type dual action heat detector | SITC of electropneumatic type dual action heat detector (blinking LED type) consisting of an air chamber, flexible matal diaphragm, phosphor bronze spring and moisture proof design, trouble free ventmounted on detector junction box with builtin L.E.D. and mounting base. The detector should be full proof design compact, reeged and uneffected of vibrations and work on dual action, connection etc. completed as per specification. | 5 | number | satcj75@bsnl | 30 | |
| 6 | SITC of electronic hooter or conventional hooter with LMT | SITC of electronic hooter/ conventional hooter with LMT,capable for existing panel of public announcement as work as being used for fire and faultin fire alarm panel i/c connection etc. as reqd | 8 | number | satcj75@bsnl | 30 | |
| 7 | SITC of Response indicator for existing panel of visual indication | SITC of Response indicator for existing panel of visual indication in MS box as work as being indicating used for fire and fault in fire alarm panel i/c connection etc. as reqd | 20 | number | satcj75@bsnl | 30 | |
| 8 | SITC of Manual call point | SITC of Manual call point (MCP) in 16 SWG MS Box for visual indication having a push button & hammer with chain for as work as being indicating used for fire zone testing i/c connection etc. as reqd | 10 | number | satcj75@bsnl | 30 | |
| 9 | Supplying and fixing of 20mm size of steel conduit | Supplying and fixing of 20mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | 15 | meter | satcj75@bsnl | 30 | |
| 10 | Supplying and fixing of 25mm size steel conduit size | Supplying and fixing of 25mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | 15 | meter | satcj75@bsnl | 30 | |
| 11 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 2x1.5Sqmm | Supplying and drawing 2x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 10 | meter | satcj75@bsnl | 30 | |
| 12 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 3x1.5Sqmm | Supplying and drawing 3x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 10 | meter | satcj75@bsnl | 30 | |
| 13 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 4x1.5Sqmm | Supplying and drawing 4x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 5 | meter | satcj75@bsnl | 30 | |
| 14 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 5x1.5Sqmm | Supplying and drawing 5x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 5 | meter | satcj75@bsnl | 30 | |
| 15 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 6x1.5Sqmm | Supplying and drawing 6x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 5 | meter | satcj75@bsnl | 30 | |
| 16 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 7x1.5Sqmm | Supplying and drawing 7x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 3 | meter | satcj75@bsnl | 30 | |
| 17 | Supplying and drawing FRLS PVC insulated copper conductor, single core cable Size 8x1.5Sqmm | Supplying and drawing 8x1.5Sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 2 | meter | satcj75@bsnl | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer