Bid Publish Date
12-Aug-2026, 12:25 pm
Bid End Date
22-Aug-2026, 1:00 pm
Location
Progress
Jammu And Kashmir State Pollution Control Board (jkspcb) invites bids for SPECTROPHOTOMETER (Q2) in SRINAGAR, JAMMU & KASHMIR. Quantity: 1. Submission Deadline: 22-08-2026 13: 00: 00. Submit your proposal before the deadline.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
60 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
3
OEM Avg. Turnover
16
Past Performance
30 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
SPECTROPHOTOMETER (Q2)
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Srinagar
Delivery Pincodes
190008
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Archana Pandita | 190008,Sheikh-ul-Alam Complex, Silk Factory Road, Rajbagh | Srinagar | Jammu And Kashmir | 190008 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Halogen Lamp, Deuterium Lamp, LED, Tungsten Halogen Lamp, Xenon Flash |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 1200 |
| LIGHT SOURCE | Switching of Light Source | Automatic |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic |
| TYPE | Type of Spectrophotometer | UV-Visible spectrophotometer |
| TYPE | Type of Optical System | Double Beam |
| TYPE | Monochromator Type | Czerny-turner |
| TYPE | Detector Type | Photodiode |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 190.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher |
| OPTICAL PERFORMANCE | Resolution | 0.002, 0.3, 0.5, 1, 1.25, 1.5, 1.7, 2, 0.2, 0.01 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 0.1 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 1 |
| OPTICAL PERFORMANCE | Focal length (mm) | 100 to 149 |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 4 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.003 Or lower |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0 - 0.5 |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Stray Light Correction | Automatic |
| GENERIC | Display | In-built display, Through PC |
| GENERIC | Display type | LCD touchscreen |
| GENERIC | Display Size | 10.0 - 30.0 Or higher |
| GENERIC | Test result printing | Through inbuilt Printer, Through external printer |
| GENERIC | If inbuilt printer, Type of printer | Thermal printer, Dot matrix, Laser b/w, Inkjet b/w, Color laser, Color inkjet, N/A |
| GENERIC | Internal storage(GB) | 0 - 80 |
| GENERIC | Mximum Path Length of sample | 0 - 120 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 10, 25, 50, 100, 200, 300, 400, 500, 2, 4, 6, 8, 0 |
| GENERIC | Spares and Consumables inclusive in the scope of supply | Yes, No |
| OPERATING CONDITIONS | Minimum Operating Temperature | -5, -10, 0, 5, 10 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 35, 40, 45, 50, 55, 60 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 80, 85, 90, 95 |
| WARRANTY | Onsite Warranty | 2.0 |
| WARRANTY | Availability of Spares (at extra cost) | 2, 3, 4, 5, 6, 7, 8, 10 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | Yes, No |