| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" | Thermal Conductivity Detector (TCD or Hot Wire Detector) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 4 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | NA |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 0, 30, 60, 100 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Internal Diameter (Hint:-Select '0' if Not Applicable)" | 0.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Film Thickness (Hint:-Select '0' if Not Applicable)" | 0.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Length (Hint:-Select '0' if Not Applicable)" | 3.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Internal Diameter (Hint:-Select '0' if Not Applicable)" | 1/8 |
| PERFORMANCE | "GC Detector Minimum Detection Level (MDL) " | < = 10 microgram/ml for TCD |
| PERFORMANCE | GC Detector Linear Dynamic Range (± 10%) | >= 10e5 for TCD |
| PERFORMANCE | GC Detector Data acquisition rate | 50 Hz or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Oven cool down time from Max operating temperature to 50 Deg c | 3.5, 4, 5 Or lower |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 6/7 or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature Ramp Rate - Maximum | 50 Deg. C/minute or better |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Retention time repeatability | 0.01 |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature set point resolution (±) | 0.1 |
| PNEUMATIC CONTROL | "Type of Inlet Pneumatics (Select applicable parameters only)" | Electronic Pneumatic Control (EPC) |
| PNEUMATIC CONTROL | Number of Injection Ports | 2 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto100 psi (1), upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001, 0.01, 0.1 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | Purged packed Inlet |
| PNEUMATIC CONTROL | Split Ratio | NA |
| PNEUMATIC CONTROL | Modes of Operation | Constant flow |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | No |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 0, 15, 100, 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Volume of each Vial of the Liquid Auto Sampler | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Minimum Volume of the injected liquid sample | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | Maximum Volume of the injected liquid sample | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | Operating Voltage of the Liquid Auto Sampler | NA |
| AUTO INJECTOR / AUTO SAMPLER | "Liquid Auto Sampler Features (Select applicable features Only)" | NA |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | No |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | NA |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | NA |
| HEAD SPACE SAMPLER | "Head Space Sampler Features (Select applicable features Only)" | NA |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | No |
| PYROLYZER SYSTEM | Temperature in the Pyrolyzer System | NA |
| SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) | "Salient Featutes of GC (Select applicable features Only)" | Display Unit with built-in Key Board |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Chromatographic attributes |
| GENERIC | Power Supply | 230 V ± 10% |
| GENERIC | Display | Built-in Display |
| GENERIC | Display Size(In case of Built-in Display) | 7.0 - 10.0 Or higher |
| GENERIC | Connectivity interface | USB |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | Yes |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Not offered |
| ACESSORIES | Capacity of Gas cylinder | Not offered |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 0 |
| ACESSORIES | Gas cylinders certified by PESO | No for Gas Cylinder Not Offered |
| ACESSORIES | Regulator - inclusive in the scope of supply | NA |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Syringe for manual injection x 05 nos, Septa for injector x 100 nos, Tool Kit x 1 no., User / Technical / Maintenance Manual |
| ENVIRONMENTAL | Minimum Operating Temperature | 0.0 - 10.0 Or lower |
| ENVIRONMENTAL | Maximum Operating Temperature | 55.0 - 65.0 Or higher |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | 95.0 - 95.0 Or higher |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 1.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 3.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of Year Availability of Spares from the date of installation is assured | 10.0 |
| CERTIFICATION / TEST REPORT | Certification | ISO |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | Yes |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use | Yes |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | Yes |
| CERTIFICATION / TEST REPORT | If Yes, Test Report to be furnished to the Buyer on demand | Yes |