Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - SITC of LT panel p
Delhi Transco Limited (dtl)
CENTRAL DELHI, DELHI
Menu
Bid Publish Date
16-Dec-2025, 4:20 pm
Bid End Date
06-Jan-2026, 11:00 am
Value
₹19,72,807
Location
Progress
Quantity
3127
Category
Point wiring with 1.5 sq mm FRLS PVC insulated Cu cond single core cable in steel conduit with modular switch plate and modular GI _Group C
Bid Type
Two Packet Bid
Public procurement opportunity for Bharat Sanchar Nigam Limited Portal(bsnl) SITC of LT Panel having 2 nos 250A 4pole MCCBs as incomers and 8 nos 100A 4pole MCCBs for outgoings in PUNE, MAHARASHTRA. Quantity: 3127 issued by. Submission Deadline: 06-01-2026 11: 00: 00. View full details and respond.
Delhi Transco Limited (dtl)
CENTRAL DELHI, DELHI
Bharat Heavy Electricals Limited (bhel)
JHANSI, UTTAR PRADESH
Advanced Weapons And Equipment India Limited
Munitions India Limited
JABALPUR, MADHYA PRADESH
Bharat Earth Movers Limited (beml)
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | SITC of LT Panel having 2 nos 250A 4pole MCCBs as incomers and 8 nos 100A 4pole MCCBs for outgoings | SITC of Indoor Cubicle LT Panel having 2nos 250A 4pole MCCBs as incomers, 8nos 100A 4pole MCCBs for outgoings, Al busbars, Multifunction Meter, LED Indicating lamps with protective SP MCBs etc as reqd | 1 | job | mohan.agrawal | 45 |
| 2 | SITC of LT Panel having 2 nos 100 A 4 pole MCCBs as incomers or outgoings | SITC of Indoor Cubicle LT Panel having 2 nos 100 A 4 pole MCCBs as incomer or outgoing, Al busbars, Multifunction Meters, LED Indicating lamps with protective SP MCBs etc complete as reqd | 1 | job | mohan.agrawal | 45 |
| 3 | Point wiring with 1.5 sq mm FRLS PVC insulated Cu cond single core cable in steel conduit with modular switch plate and modular GI _Group C | Wiring for light or fan or ex fan or call bell point with 1.5 sq mm FRLS PVC insulated Cu cond single core cable in steel conduit with modular switch plate and modular GI box_Group C | 85 | point | mohan.agrawal | 45 |
| 4 | Wiring for circuit or submain wiring with the 2 x 1.5 sq mm plus 1 x 1.5 sq mm earth wire | Wiring for circuit or submain wiring with the 2 x 1.5 sq mm plus 1 x 1.5 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 45 | metre | mohan.agrawal | 45 |
| 5 | Wiring for circuit or submain wiring with the 4 x 1.5 sq mm plus 2 x 1.5 sq mm earth wire | Wiring for circuit or submain wiring with the 4 x 1.5 sq mm plus 2 x 1.5 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 50 | metre | mohan.agrawal | 45 |
| 6 | Wiring for circuit or submain wiring with the 6 x 1.5 sq mm plus 3 x 1.5 sq mm earth wire | Wiring for circuit or submain wiring with the 6 x 1.5 sq mm plus 3 x 1.5 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 5 | metre | mohan.agrawal | 45 |
| 7 | Wiring for circuit or submain wiring with the 2 x 2 .5 sq mm plus 1 x 2.5 sq mm earth wire | Wiring for circuit or submain wiring with the 2 x 2.5 sq mm plus 1 x 2.5 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 8 | Wiring for circuit or submain wiring with the 4 x 2.5 sq mm plus 2 x 2.5 sq mm earth wire | Wiring for circuit or submain wiring with the 4 x 2.5 sq mm plus 2 x 2.5 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 9 | Wiring for circuit or submain wiring with the 2 x 6 sq mm plus 1 x 6 sq mm earth wire | Wiring for circuit or submain wiring with the 2 x 6 sq mm plus 1 x 6 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 10 | Wiring for light or power plug with the 2 x 4 sq mm alongwith 1 x 4 sq mm earth wire | Wiring for light or power plug with the 2 x 4 sq mm alongwith 1 x 4 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 60 | metre | mohan.agrawal | 45 |
| 11 | Wiring for light or power plug with the 4 x 4 sq mm alongwith 2 x 4 sq mm earth wire | Wiring for light or power plug with the 4 x 4 sq mm alongwith 2 x 4 sq mm earth wire of FRLS PVC insulated Cu cond single core cable in steel conduit as reqd | 50 | metre | mohan.agrawal | 45 |
| 12 | S and F 20 mm steel conduit | Supplying and fixing of 20 mm steel conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as reqd | 120 | metre | mohan.agrawal | 45 |
| 13 | S and F 25 mm steel conduit | Supplying and fixing of 25 mm steel conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as reqd | 60 | metre | mohan.agrawal | 45 |
| 14 | S and D of 1 x 1.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 1 x 1.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 5 | metre | mohan.agrawal | 45 |
| 15 | S and D of 2 x 1.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 2 x 1.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 15 | metre | mohan.agrawal | 45 |
| 16 | S and D of 3 x 1.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 3 x 1.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 80 | metre | mohan.agrawal | 45 |
| 17 | S and D of 2 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 2 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 18 | S and D of 3 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 3 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 19 | S and D of 6 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 6 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 80 | metre | mohan.agrawal | 45 |
| 20 | S and D of 9 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 9 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 21 | S and D of 12 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 12 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 15 | metre | mohan.agrawal | 45 |
| 22 | S and D of 24 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 24 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 5 | metre | mohan.agrawal | 45 |
| 23 | S and D of 36 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 36 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 5 | metre | mohan.agrawal | 45 |
| 24 | S and D of 48 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 48 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 5 | metre | mohan.agrawal | 45 |
| 25 | S and D of 54 x 2.5 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 54 x 2.5 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 5 | metre | mohan.agrawal | 45 |
| 26 | S and D of 3 x 4 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 3 x 4 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 30 | metre | mohan.agrawal | 45 |
| 27 | S and D of 6 x 4 sq mm FRLS PVC insulated Cu conductor | Supplying and drawing of 6 x 4 sq mm FRLS PVC insulated Cu conductor single core cable in the existing surface or recessed steel or PVC conduit as reqd | 10 | metre | mohan.agrawal | 45 |
| 28 | S and F of GI box with modular plate and cover including P and F modular 3 pin 5 or 6 amps socket outlet and 5 or 6 amps switch | S and F of suitable size GI box with modular plate and cover in front on surface or in recess including P and F 3 pin 5 or 6 amps modular socket outlet and 5 or 6 amps modular switch | 10 | each | mohan.agrawal | 45 |
| 29 | S and F of GI box with modular plate and cover including P and F modular 6 pin 5 or 6 and 15 or 16 amps socket outlet and 15 or 16 amps switch | S and F of suitable size GI box with modular plate and cover in front on surface or in recess including P and F 6 pin 5 or 6 and 15 or 16 amps modular socket outlet and 15 or 16 amps modular switch | 5 | each | mohan.agrawal | 45 |
| 30 | S and F of 5 or 6 Amp modular switch | Supplying and fixing of 5 or 6 Amp modular switch on the existing modular plate and switch box including connections but excluding modular plate etc as reqd | 80 | each | mohan.agrawal | 45 |
| 31 | S and F of 3 pin 5 or 6 Amp modular socket outlet | Supplying and fixing of 3 pin 5 or 6 Amp modular socket outlet on the existing modular plate and switch box including connections but excluding modular plate etc as reqd | 240 | each | mohan.agrawal | 45 |
| 32 | S and F of 15 or 16 Amp modular switch | Supplying and fixing of 15 or 16 Amp modular switch on the existing modular plate and switch box including connections but excluding modular plate etc as reqd | 2 | each | mohan.agrawal | 45 |
| 33 | S and F of 6 pin 15 or 16 Amp modular socket outlet | Supplying and fixing of 6 pin 15 or 16 Amp modular socket outlet on the existing modular plate and switch box including connections but excluding modular plate etc as reqd | 2 | each | mohan.agrawal | 45 |
| 34 | S and F of RJ 45 Computer Socket Cat 6 | Supplying and fixing of RJ 45 Computer Socket Cat 6 on the existing modular plate and switch box including connections but excluding modular plate etc as reqd | 60 | each | mohan.agrawal | 45 |
| 35 | S and F of 4 Module or 125mm x 75mm size modules GI box with base and cover plate | Supplying and fixing of 4 Module or 125mm x 75mm size or modules GI box along with modular base and cover plate for modular switches in recess etc as reqd | 2 | each | mohan.agrawal | 45 |
| 36 | S and F of 8 Module or 125mm x 125mm size modules GI box with base and cover plate | Supplying and fixing of 8 Module or 125mm x 125mm size modules GI box along with modular base and cover plate for modular switches in recess etc as reqd | 60 | each | mohan.agrawal | 45 |
| 37 | S and F of 3 Module or 100mm x 75mm size modules GI box with base and cover plate | Supplying and fixing of 3 Module or 100mm x 75mm size modules GI box along with modular base and cover plate for modular switches in recess etc as reqd | 10 | each | mohan.agrawal | 45 |
| 38 | S and F of 1 or 2 Module or 75mm x 75mm size modules GI box with base and cover plate | Supplying and fixing of 1 or 2 Module or 75mm x 75mm size modules GI box along with modular base and cover plate for modular switches in recess etc as reqd | 60 | each | mohan.agrawal | 45 |
| 39 | S and D of 1 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 1 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 5 | metre | mohan.agrawal | 45 |
| 40 | S and D of 2 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 2 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 85 | metre | mohan.agrawal | 45 |
| 41 | S and D of 3 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 3 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 5 | metre | mohan.agrawal | 45 |
| 42 | S and D of 4 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 4 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 50 | metre | mohan.agrawal | 45 |
| 43 | S and D of 6 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 6 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 10 | metre | mohan.agrawal | 45 |
| 44 | S and D of 8 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 8 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 120 | metre | mohan.agrawal | 45 |
| 45 | S and D of 16 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 16 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 20 | metre | mohan.agrawal | 45 |
| 46 | S and D of 20 Run of UTP 4 pair CAT 6 LAN cable | Supplying and Drawing of 20 Run of UTP 4 pair CAT 6 LAN cable in the existing surface or recessed steel or PVC conduit as required | 5 | metre | mohan.agrawal | 45 |
| 47 | S and M end termination with RJ45 plug | Supplying and making end termination with RJ45 plug on Cat 6 LAN cable including testing and commissioning etc complete as reqd | 170 | each | mohan.agrawal | 45 |
| 48 | S and F modular blanking plate | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required | 60 | each | mohan.agrawal | 45 |
| 49 | S and F of 450mm heavy duty exhaust fan along with louver shutters | S and F of 450mm heavy duty exhaust fan suitable for 1 phase 230V AC supply along with louver shutters including making opening in the wall and making good the same and connection etc as reqd | 1 | each | mohan.agrawal | 45 |
| 50 | S and F of 225mm heavy duty exhaust fan along with louver shutters | S and F of 225mm heavy duty exhaust fan suitable for 1 phase 230V AC supply along with louver shutters including making opening in the wall and making good the same and connection etc as reqd | 2 | each | mohan.agrawal | 45 |
| 51 | SITC of recess mounting type 36W LED Cool White luminaire of 2 Ft x 2 Ft size modular fitting | SITC of recess mounting type 36W LED Cool White luminaire of 2 Ft x 2 Ft size modular fitting with suspension arrangement with MS chain, links on existing false ceiling, wiring connections etc as reqd | 44 | each | mohan.agrawal | 45 |
| 52 | S and installation of 22 watt LED batten, 4 feet light fitting | Supplying and installation of 22 watt LED batten, 2200 lumen, 4 feet light fitting suitable for 230 Volts, 50 Hz, including necessary connections etc complete as reqd | 25 | each | mohan.agrawal | 45 |
| 53 | S and F two module stepped type electronic fan regulator on the existing modular plate switch box | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. | 5 | each | mohan.agrawal | 45 |
| 54 | ITC of ceiling Fan including wiring the down rod | ITC of ceiling Fan including wiring the down rod of standard length with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as reqd. | 5 | each | mohan.agrawal | 45 |
| 55 | SITC of 1 phase 400 mm sweep, High speed wall mounted BLDC Motor fan | SITC of 1 phase 400 mm sweep, High speed wall mounted BLDC Motor fan with Pull Cords for speed regulation, Plastic body and blades, Min. Air Delivery 60 Cu.mtr per min etc complete as required. | 1 | each | mohan.agrawal | 45 |
| 56 | SITC of Round LED down lighter recess mounting Fitting of 15W, 230 volts, 50 Hz | SITC of Round LED down lighter recess mounting Fitting of 15W, 230 volts, 50 Hz housed in metal casing complete with testing and commissioning etc as required | 5 | each | mohan.agrawal | 45 |
| 57 | S and F of control contactor for emergency lighting of rating 4 Amp, having coil voltage 230 volts, 50 Hz, with 2NO plus 2NC contacts | S and F of control contactor for emergency lighting of rating 4 Amp, having coil voltage 230 volts, 50 Hz, with 2NO plus 2NC contacts with enclosure incl connections etc complete as reqd. | 1 | each | mohan.agrawal | 45 |
| 58 | S and L of 75mm x 38 mm size One Compartment GI raceway | Supplying and laying of 75mm x 38 mm size One Compartment GI raceway made of pregalvanised sheet of 1.6 mm thick including fixing in flooring etc complete as required | 60 | metre | mohan.agrawal | 45 |
| 59 | S and L of coupler for 75mm x 38 mm size GI raceway | Supplying and laying of coupler for 75mm x 38 mm size GI raceway made of pregalvanised sheet of 1.6 mm thick etc complete as required | 25 | each | mohan.agrawal | 45 |
| 60 | S and F of JB 150mm x 150mm x 50m mm with 50_70 mm size GI height adjustable junction box with base and cover plate | S and F of JB 150mm x 150mm x 50m mm with 50_70 mm size GI height adjustable junction box with base and cover plate for direct access to cables at the intersection of raceways etc complete as reqd | 20 | each | mohan.agrawal | 45 |
| 61 | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray with perforation not more than 17.5 percent, joined with connectors, suspended with MS suspenders complete as reqd | 50 | metre | mohan.agrawal | 45 |
| 62 | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray bend | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray bends with perforation not more than 17.5 percent, suspended with MS suspenders complete as reqd | 5 | each | mohan.agrawal | 45 |
| 63 | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray TEE | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray TEE with perforation not more than 17.5 percent, suspended with MS suspenders complete as reqd | 5 | each | mohan.agrawal | 45 |
| 64 | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray CROSS MEMBER | Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray CROSS MEMBER with perforation not more than 17.5 percent, suspended with MS suspenders complete as reqd | 2 | each | mohan.agrawal | 45 |
| 65 | S and F of 8 way 4plus24 ways Double door horizontal type TPN sheet steel MCB DB_415V | S and F of 8 way 4plus24 ways Double door horizontal type TPN sheet steel MCB DB_415V on surface incl of tinned Cu bus bar neutral bus bar earth bar din bar as reqd_but without MCB RCCB and isolator | 3 | each | mohan.agrawal | 45 |
| 66 | S and F of 8 way Double door vertical type 415V TPN sheet steel MCB DB suitable for mounting MCCB as incomer 8 plus 8 plus 8 ways for outgoings | S and F of 8 way Double door vertical 415V TPN sheet steel MCBDB suitable for mounting MCCB as incomer 8plus8plus8 way outgoings incl of 200 A tinned Cu bus bar neutral link earth bar din bar | 1 | each | mohan.agrawal | 45 |
| 67 | S and F of 8 way Double door SPN sheet steel MCB DB_240V | S and F of 8 way Double door SPN sheet steel MCB DB_240V on surface incl of tinned Cu bus bar neutral bus bar earth bar din bar as reqd_but without MCB RCCB and isolator | 1 | each | mohan.agrawal | 45 |
| 68 | P and F of 100 A 4 pole MCCB | P and F of 100 A 4 pole MCCB with thermal release range 80_100 A and breaking capacity 30KA in existing MCB DB including connections etc as required. | 1 | each | mohan.agrawal | 45 |
| 69 | S and F of SP 5 amps to 32 amps rating 240 V C curve MCB | Supplying and Fixing of Single pole 5 amps to 32 amps rating 240 V C curve MCB suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc as reqd | 50 | each | mohan.agrawal | 45 |
| 70 | S and F of SPN 5 amps to 32 amps rating 240 V C curve MCB | S and F of Single pole and neutral 5 amps to 32 amps rating 240 V C curve MCB suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc as reqd | 2 | each | mohan.agrawal | 45 |
| 71 | S and F of TP 5 amps to 32 amps rating 415 V C curve MCB | S and F of Triple pole 5 amps to 32 amps rating 415 V C curve MCB suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc as reqd | 8 | each | mohan.agrawal | 45 |
| 72 | S and F of TPN 5 amps to 32 amps rating 415 V C curve MCB | S and F of Triple pole and neutral 5 amps to 32 amps rating 415V C curve MCB suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc as reqd | 2 | each | mohan.agrawal | 45 |
| 73 | S and F single pole blanking plate in the existing MCB DB | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc as required | 10 | each | mohan.agrawal | 45 |
| 74 | P and F 6 SWG dia GI wire along with existing surface or recessed conduit or submain wiring or cable | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface or recessed conduit or submain wiring or cable as reqd | 250 | metre | mohan.agrawal | 45 |
| 75 | P and F 4 mm dia Cu bare wire along with existing surface or recessed conduit or submain wiring or cable | Providing and fixing 4 mm dia copper bare wire on surface or in recess for loop earthing alongwith existing surface or recess conduit or submain wiring or cable as reqd | 50 | metre | mohan.agrawal | 45 |
| 76 | Supplying of 4 core 35 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable | Supplying of 4 core 35 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable of 1.1KV grade ISI marked etc complete as reqd | 200 | metre | mohan.agrawal | 45 |
| 77 | Supplying of 3.5 core 95 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable | Supplying of 3.5 core 95 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable of 1.1KV gradeISI marked etc complete as reqd | 40 | metre | mohan.agrawal | 45 |
| 78 | Laying and fixing of one number upto 35 sq. mm size cable on wall surface | Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade upto 35 sq. mm size on wall surface as required | 40 | metre | mohan.agrawal | 45 |
| 79 | Laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on wall surface | Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade above 35 sq. mm and upto 95 sq. mm size on wall surface as required | 22 | metre | mohan.agrawal | 45 |
| 80 | Laying and fixing of one number upto 35 sq. mm size cable on cable tray | Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade upto 35 sq. mm size on cable tray as required | 130 | metre | mohan.agrawal | 45 |
| 81 | Laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on cable tray | Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade above 35 sq. mm and upto 95 sq. mm size on cable tray as required | 10 | metre | mohan.agrawal | 45 |
| 82 | S and M end termination with brass compression gland and aluminium lugs for 4 x 35 sq. mm size Al cond cable | Supplying and making end termination with brass compression gland and aluminium lugs for 4 x 35 sq. mm size of PVC insulated and PVC sheathed or XLPE Al conductor cable of 1.1KV grade as reqd | 16 | set | mohan.agrawal | 45 |
| 83 | S and M end termination with brass compression gland and aluminium lugs for 3.5 x 95 sq. mm size Al cond cable | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 x 95 sq. mm size of PVC insulated and PVC sheathed or XLPE Al conductor cable of 1.1KV grade as reqd | 4 | set | mohan.agrawal | 45 |
| 84 | S and L of 2 x 1.5 sq mm Cu conductor armoured cable for fire alarm | Supplying and laying of 2 x 1.5 sq mm fire alarm armoured cable 600 or 1000V rated with annealed copper conductor having XLPE insulation steel wire armouring & FRLS outer sheath complete as reqd | 50 | metre | mohan.agrawal | 45 |
| 85 | S and F metal box of 75 mm x 75 mm x 60 mm deep nominal size | S and F metal box of 75 mm x 75 mm x 60 mm deep nominal size on surface or in recess including painting in case of surface or cutting the wall and making good the same in case of recessed etc as reqd | 12 | each | mohan.agrawal | 45 |
| 86 | S and F 25 mm dia MS flexible pipe with PVC coating | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc as required | 70 | metre | mohan.agrawal | 45 |
| 87 | ITC of Photo electric smoke detector | ITC of Photo electric smoke detector on the false ceiling including making connection at both ends, testing etc complete as required and as per BSNL specifications | 8 | each | mohan.agrawal | 45 |
| 88 | Dismantling of existing Fluorescent fittings _Cables_Wiring_MCB DBs | Dismantling of existing Fluorescent fittings _Cables_Wiring through MS or PVC conduit from the existing False ceiling or Flooring_MCB DBs etc as required | 1 | job | mohan.agrawal | 45 |
| 89 | S and F of Double sided Exit sign Board with Green Super Bright LED | S and F of Double sided Exit sign Board with Green Super Bright LED of Size 12 Inch x 6 Inch suitable for input voltage 230 V AC supply alongwith aluminium housing and battery backup as required. | 5 | each | mohan.agrawal | 45 |
| 90 | S and F of ISI marked ready to use CO2 type 4 point 5 Kg capacity fire extinguisher | S and F of ISI marked ready to use CO2 type 4 point 5 Kg capacity fire extinguisher with hose of suitable length and horn duly charged along with clamps to hold the fire extinguisher etc as reqd | 3 | each | mohan.agrawal | 45 |
| 91 | S and L of of 1m x 2m size electrical insulation anti-skid rubber matting of 6mm thickness | Supply and laying of 1m x 2m size electrical insulation anti-skid rubber matting of 6mm thickness suitable for medium voltage etc complete as required. | 2 | each | mohan.agrawal | 45 |
| 92 | Pvdg and installing of 24 port unmanaged Gigabit LAN switch 2 Layer supported | Providing and installing of 24 port unmanaged Gigabit LAN switch 2 Layer supported including testing and commissioning etc as required | 4 | each | mohan.agrawal | 45 |
| 93 | S and installing of 4U wall mounting rack for housing 24 port LAN switch | Supplying and installing of 4U wall mounting rack for housing 24 port LAN switch with suitable hardware etc complete as required | 4 | each | mohan.agrawal | 45 |
| 94 | SITC of 30 Watt PDC housed LED street light fitting having IP66 protection | SITC of 30 Watt PDC housed LED street light fitting having IP66 protection on wall along with suitable size GI Pipe bracket incl. wiring_connections etc complete as reqd | 5 | each | mohan.agrawal | 45 |
| 95 | S and F of 3pin 5A ceiling rose on the existing junction box or wooden block | Supplying and Fixing of 3pin 5A ceiling rose on the existing junction box or wooden block including connections etc as reqd. | 10 | each | mohan.agrawal | 45 |
| 96 | S and F of various sizes of MS boxes made out of 16 SWG MS sheet | S and F of various sizes of MS boxes made out of 16SWG MS sheet on surface or in recess incl painting in case of surface or cutting the wall and making good the same in case of recessed etc as reqd | 2 | sq metre | mohan.agrawal | 45 |
| 97 | SITC of Type_II TVSS unit as per UL 1449 standards for 3 phase 4wire plus Gnd connection | SITC of Type_II TVSS unit as per UL 1449 std. for 3 phase 4wire plus Gnd connection with volt as LL_400V LN_230V LG_230V 47_63 Hz freq range 600V let through volt and surge current cap 25KA per phase | 2 | set | mohan.agrawal | 45 |
Discover companies most likely to bid on this tender
Nuclear Recycle Board
📍 PALGHAR, MAHARASHTRA
KOLKATA MUNICIPAL CORPORATION
📍 KOLKATA, WEST BENGAL
JKSPDC
📍 RAMBAN, JAMMU AND KASHMIR
E-IN-C BRANCH - MILITARY ENGINEER SERVICES
📍 SONITPUR, ASSAM
New Delhi Municipal Council
📍 NEW DELHI, DELHI
Sign up now to access all documents
Main Document
OTHER
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Choose from flexible plans to access tender documents instantly
Main Document
OTHER
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS