Bid Publish Date
14-Aug-2026, 10:49 am
Bid End Date
11-Sep-2026, 3:00 pm
Location
Progress
Public procurement opportunity for Bhakra Beas Management Board Buy back existing unit, New Ductable AC installation, Suction Line, Liquid Line, Acoustic line, Canvass connection, Drain Pipe, FRLS and control cables, LT copper cable, GI wire, Stand for outdoor unit, Stand for indoor unit, Refrigerant gas, Testing, Electrical distribution panel in WEST DELHI, DELHI. Quantity: 665 issued by. Submission Deadline: 11-09-2026 15: 00: 00. View full details and respond.
Quantity
665
Category
New Ductable AC installation
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Warranty Period
5 days
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Buy back existing unit , New Ductable AC installation , Suction Line , Liquid Line , Acoustic line , Canvass connection , Drain Pipe , FRLS and control cables , LT copper cable , GI wire , Stand for outdoor unit , Stand for indoor unit , Refrigerant gas , Testing , Electrical distribution panel
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
North West
Delivery Pincodes
110035
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Sudhir Datt | 110035,XEN, O&M Division 220 KV sub station, B.B.M.B , old Rohtak Road Near Punjabi Bagh Metro station Delhi 110035 | North West | Delhi | 110035 | 1 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Buy back existing unit
Buyback with Dismantling of all existing air cooled package unit with pumps, piping and cooling tower etc
New Ductable AC installation
Supply and Installation and Testing and commissioning of advanced micro computer based high performance machine air Cooled Packaged Ductable Unit of minimum 8.5 TR capacity having indoor airflow capability of 400CFM per Ton with multiple energy efficient Scroll Compressors inbuilt electric control panel, first charging of R410 A refrigerant DX cooling coil thermostatic expansion valve air filter and blower section blower with motor coils initial charge of compressor oil.Capacity minimum 8.5 TR or Min. 400 CFM TR Make Bluestar or Trane or Carrier or York or Voltas or O General
Suction Line
Supply and Installation of hard drawn refrigerant Copper Piping with nitrile insulation on suction line. Make Hariom or Mandev or Maxflow or Indigo or Mrajco Insulation Armacell or Aflex or Supreme. Suction line as per OEM
Liquid Line
Liquid line as per OEM
Acoustic line
Supplying and fixing of acoustic lining with open cell nitrile rubber having thickness of 15mm.Make Supreme or Aerofoam or A-flex or Armacell
Canvass connection
Supply and Fixing of Canvass Connection.
Drain Pipe
Supply and Installation of UPVC Drain Pipe.Make Supreme or Astral or Prince (32 mm to 50mm)
FRLS and control cables
Supply and installation of FRLS control cable PVC insulated PVC sheathed Steel armoured multistrand copper conductor control cable following size. Make Finolexor RR or Havells or KEI or Polycab 6 Core x 2.5 Sqmm
LT copper cable
Supplying laying of XLPE insulated PVC sheathed steel armoured 1.1KV Grade LT Copper Conductor power cable Make Finolex or RR or Havells or KEI or Polycab 4.0 Core x 2.5 Sqmm
GI wire
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required at site.
Stand for outdoor unit
Supply and installation of MS stand for outdoor units.
Stand for indoor unit
Supply and installation of MS stand for indoor units.
Refrigerant gas
Supply & charging of extra Refrigerant gas R410 A
Testing
Nitrogen testing, vacuumizing and gas charging.
Electrical distribution panel
Design and fabrication and supply and installation of cubical type dead front Electrical distribution Panel made out of 14G CRCA sheet with suitable MCCBs, TPN and internal wiring etc. and instrumentation for minimum 11 TR X 4 Nos Package units as per standard make. The unit shall have sequential controller for operating 3 units. Note All the switchgears installed in the Electrical distribution panel of air-conditioning units shall be of ABB or SIEMENS or SCHNEIDER or L&T or TEKNIC make
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Buy back existing unit | Buyback with Dismantling of all existing air cooled package unit with pumps, piping and cooling tower etc | 1 | job | sdotldlh | 30 | |
| 2 | New Ductable AC installation | Supply and Installation and Testing and commissioning of advanced micro computer based high performance machine air Cooled Packaged Ductable Unit of minimum 8.5 TR capacity having indoor airflow capability of 400CFM per Ton with multiple energy efficient Scroll Compressors inbuilt electric control panel, first charging of R410 A refrigerant DX cooling coil thermostatic expansion valve air filter and blower section blower with motor coils initial charge of compressor oil.Capacity minimum 8.5 TR or Min. 400 CFM TR Make Bluestar or Trane or Carrier or York or Voltas or O General | 3 | nos | sdotldlh | 30 | |
| 3 | Suction Line | Supply and Installation of hard drawn refrigerant Copper Piping with nitrile insulation on suction line. Make Hariom or Mandev or Maxflow or Indigo or Mrajco Insulation Armacell or Aflex or Supreme. Suction line as per OEM | 90 | rmt | sdotldlh | 30 | |
| 4 | Liquid Line | Liquid line as per OEM | 90 | rmt | sdotldlh | 30 | |
| 5 | Acoustic line | Supplying and fixing of acoustic lining with open cell nitrile rubber having thickness of 15mm.Make Supreme or Aerofoam or A-flex or Armacell | 70 | sqmt | sdotldlh | 30 | |
| 6 | Canvass connection | Supply and Fixing of Canvass Connection. | 3 | nos | sdotldlh | 30 | |
| 7 | Drain Pipe | Supply and Installation of UPVC Drain Pipe.Make Supreme or Astral or Prince (32 mm to 50mm) | 90 | rmt | sdotldlh | 30 | |
| 8 | FRLS and control cables | Supply and installation of FRLS control cable PVC insulated PVC sheathed Steel armoured multistrand copper conductor control cable following size. Make Finolexor RR or Havells or KEI or Polycab 6 Core x 2.5 Sqmm | 100 | rmt | sdotldlh | 30 | |
| 9 | LT copper cable | Supplying laying of XLPE insulated PVC sheathed steel armoured 1.1KV Grade LT Copper Conductor power cable Make Finolex or RR or Havells or KEI or Polycab 4.0 Core x 2.5 Sqmm | 90 | rmt | sdotldlh | 30 | |
| 10 | GI wire | Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required at site. | 80 | rmt | sdotldlh | 30 | |
| 11 | Stand for outdoor unit | Supply and installation of MS stand for outdoor units. | 3 | nos | sdotldlh | 30 | |
| 12 | Stand for indoor unit | Supply and installation of MS stand for indoor units. | 3 | nos | sdotldlh | 30 | |
| 13 | Refrigerant gas | Supply & charging of extra Refrigerant gas R410 A | 40 | kg | sdotldlh | 30 | |
| 14 | Testing | Nitrogen testing, vacuumizing and gas charging. | 1 | job | sdotldlh | 30 | |
| 15 | Electrical distribution panel | Design and fabrication and supply and installation of cubical type dead front Electrical distribution Panel made out of 14G CRCA sheet with suitable MCCBs, TPN and internal wiring etc. and instrumentation for minimum 11 TR X 4 Nos Package units as per standard make. The unit shall have sequential controller for operating 3 units. Note All the switchgears installed in the Electrical distribution panel of air-conditioning units shall be of ABB or SIEMENS or SCHNEIDER or L&T or TEKNIC make | 1 | no | sdotldlh | 30 |