Bid Publish Date
24-Aug-2026, 12:18 pm
Bid End Date
03-Sep-2026, 1:00 pm
EMD
₹22,000
Location
Progress
A tender has been published for Indian Army Cable Joint Kit Suitable for Cables Up to and Including 33 kV (V2) (Q3), Copper alloy Taps/Stop Valves (V2) Conforming to IS 8931 (Q3), Metal Alloy Casting Water Tap with Aerator (V2) (Q3), Miniature Circuit Breakers (MCB) for AC Operation Marked To IS/IEC 60898 (Part 1) (Q2), PVC Insulated Copper Cable Single Core and Multi Core Circular Sheathed with Flexible Conductor (V2) ISI Marked To IS 694 (Q2), Onload changeover 400 Amp 415 Volt 4P, Onload changeover 630 Amp 415 Volt TP, Onload changeover 250 Amp 415 Volt 4P, Lt joint kit 50 sqmm 3. 5 core, Lt joint kit 150 sqmm 3. 5 core, Gate Valve 20 mm dia, Gate Valve 25 mm dia, Door closer Hydraulically Alu body, cap 36 to 60 kg, Door closer Hydraulically Alu body, cap 61 to 80 kg in LEH, JAMMU & KASHMIR. Quantity: 372 by. Submission Deadline: 03-09-2026 13: 00: 00. Check eligibility and apply.
Quantity
372
Category
Gate Valve 20 mm dia
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
2
OEM Avg. Turnover
40
Past Performance
50 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Cable Joint Kit Suitable for Cables Up to and Including 33 kV (V2) (Q3) , Copper alloy Taps/Stop Valves (V2) Conforming to IS 8931 (Q3) , Metal Alloy Casting Water Tap with Aerator (V2) (Q3) , Miniature Circuit Breakers (MCB) for AC Operation Marked To IS/IEC 60898 (Part 1) (Q2) , PVC Insulated Copper Cable Single Core and Multi Core Circular Sheathed with Flexible Conductor (V2) ISI Marked To IS 694 (Q2) , Onload changeover 400 Amp 415 Volt 4P , Onload changeover 630 Amp 415 Volt TP , Onload changeover 250 Amp 415 Volt 4P , Lt joint kit 50 sqmm 3.5 core , Lt joint kit 150 sqmm 3.5 core , Gate Valve 20 mm dia , Gate Valve 25 mm dia , Door closer Hydraulically Alu body, cap 36 to 60 kg , Door closer Hydraulically Alu body, cap 61 to 80 kg
Advisory Bank
State Bank of India
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Leh
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| - | Leh | Leh | - | - | 2 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Onload changeover 400 Amp 415 Volt 4P
Onload changeover 400 Amp 415 Volt 4P
Onload changeover 630 Amp 415 Volt TP
Onload changeover 630 Amp 415 Volt TP
Onload changeover 250 Amp 415 Volt 4P
Onload changeover 250 Amp 415 Volt 4P
Lt joint kit 50 sqmm 3.5 core
Lt joint kit 50 sqmm 3.5 core
Lt joint kit 150 sqmm 3.5 core
Lt joint kit 150 sqmm 3.5 core
Gate Valve 20 mm dia
Gate Valve 20 mm dia
Gate Valve 25 mm dia
Gate Valve 25 mm dia
Door closer Hydraulically Alu body, cap 36 to 60 kg
Door closer Hydraulically Alu body, cap 36 to 60 kg
Door closer Hydraulically Alu body, cap 61 to 80 kg
Door closer Hydraulically Alu body, cap 61 to 80 kg
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Onload changeover 400 Amp 415 Volt 4P | Onload changeover 400 Amp 415 Volt 4P | 2 | nos | ageinimu2023 | 60 | |
| 2 | Onload changeover 630 Amp 415 Volt TP | Onload changeover 630 Amp 415 Volt TP | 2 | nos | ageinimu2023 | 60 | |
| 3 | Onload changeover 250 Amp 415 Volt 4P | Onload changeover 250 Amp 415 Volt 4P | 2 | nos | ageinimu2023 | 60 | |
| 4 | Lt joint kit 50 sqmm 3.5 core | Lt joint kit 50 sqmm 3.5 core | 2 | nos | ageinimu2023 | 60 | |
| 5 | Lt joint kit 150 sqmm 3.5 core | Lt joint kit 150 sqmm 3.5 core | 4 | nos | ageinimu2023 | 60 | |
| 6 | Gate Valve 20 mm dia | Gate Valve 20 mm dia | 20 | nos | ageinimu2023 | 60 | |
| 7 | Gate Valve 25 mm dia | Gate Valve 25 mm dia | 16 | nos | ageinimu2023 | 60 | |
| 8 | Door closer Hydraulically Alu body, cap 36 to 60 kg | Door closer Hydraulically Alu body, cap 36 to 60 kg | 42 | nos | ageinimu2023 | 60 | |
| 9 | Door closer Hydraulically Alu body, cap 61 to 80 kg | Door closer Hydraulically Alu body, cap 61 to 80 kg | 12 | nos | ageinimu2023 | 60 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| STANDARD | Conformity of the specification | As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV |
| STANDARD | Type of joint kit | Non Rigid - Straight Joint - Heat Shrink |
| GENERIC | Applicable conductors for using the joint kits | Aluminium |
| GENERIC | The appropriate cable for using the joint kits | Armoured Cable |
| GENERIC | The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)] | XLPE (Range of approval: XLPE, EPR, HEPR, PVC) |
| GENERIC | Applicable cable core for using the joint kits (in Nos) | 3.5 |
| GENERIC | Applicable cable size for using the joint kits (in sq mm) | 35 |
| GENERIC | Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores) | Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet |
| CERTIFICATIONS | Availability of type test report from Central Govt lab/NABL accredited/ILAC accredited lab to prove conformity of the specification | Yes, As per IS 13573 (Part 1) |