TenderDekho Logo
GEM

Bids are Invited For Hydrogen Sulfide (H2s) Detector (V1) in MUMBAI, MAHARASHTRA

Bid Publish Date

02-Jul-2026, 5:26 pm

Bid End Date

09-Jul-2026, 6:00 pm

Generate Docs

Progress

Issue02-Jul-2026, 5:26 pm
Corrigendum06-Jul-2026
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

4

Bid Type

Two Packet Bid

Categories 2

Public procurement opportunity for Indian Navy Hydrogen Sulfide (H2s) Detector (V1) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 4 issued by. Submission Deadline: 09-07-2026 18: 00: 00. View full details and respond.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Hydrogen Sulfide (H2s) Detector (V1) (Q2)

Authority Records

MINISTRY OF DEFENCEMILITARY AFFAIRS DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9550940.pdf

Main Document

GeM Category Specification

GEM_CATEGORY_SPECIFICATION

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Hydrogen Sulfide (H2s) Detector (V1)

Nuclear Power Corporation Of India Limited

CHITTORGARH, RAJASTHAN

Posted: 16 January 2026
Closed: 13 February 2026
GEM

Hydrogen (H2) Detector (V1)

Directorate Of Purchase And Stores

MUMBAI, MAHARASHTRA

Posted: 23 December 2024
Closed: 7 January 2025
GEM

Hydrogen (H2) Detector (V1)

Ntpc Sail Power Company Ltd

Posted: 16 October 2024
Closed: 22 November 2024
GEM

Hydrogen (H2) Detector (V1)

Nuclear Power Corporation Of India Limited

Posted: 17 December 2024
Closed: 28 December 2024
GEM

Hydrogen (H2) Detector (V1)

Directorate Of Purchase And Stores

Posted: 6 April 2026
Closed: 28 April 2026
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
TYPE/APPLICATION/TECHNOLOGY Type Plug - in/Fixed
TYPE/APPLICATION/TECHNOLOGY Preset Value (To generate audio- visual alarm ) User Setable
SIZE/ACCURACY/ALARM Measurement Range of Hydrogen Sulfide(H2S) gas concentration 0 – 100 ppm
SIZE/ACCURACY/ALARM Accuracy of Hydrogen Sulfide(H2S) gas measurement ± 2% of measured value
SIZE/ACCURACY/ALARM Resolution of Hydrogen Sulfide(H2S) gas measurement 1 PPM
SIZE/ACCURACY/ALARM Response time to reach to 90 % of measure value <=30 seconds
SIZE/ACCURACY/ALARM Audio Visual Alarm Minimum 85 Decibel audible alarm at 30 cm & Bright Red LED Flashing Visible Alarm with Vibration
AREA OF USE - HAZARDOUS AREA CLASSIFICATION Hazardous area classification standard IEC 60079 (latest)
AREA OF USE - HAZARDOUS AREA CLASSIFICATION Area of use - Hazardous area classification Intrinsically safe for use in hazardous area classification conforming to Class I, Division I, Group A, B, C & D or Zone - 0, Group-IIA, IIB & IIC
POWER SOURCE Power Source Mains (230 ± 10 Volts / 50 Hz AC
POWER SOURCE Battery Size NA for Mains operated
POWER SOURCE Battery chemistry (hint: NA for Mains operated/Non rechargeable batteries) NA
POWER SOURCE Number of Batteries required for operation (hint: NA for Mains operated/Non rechargeable batteries) NA
POWER SOURCE Number of Batteries Inclusive in the Scope of Supply (hint: Select "NA" if not applicable) NA
POWER SOURCE Battery Life NA
POWER SOURCE Suitable Battery Charger operable with 230 V + 5%, 50 Hz AC inclusive in the scope of supply Yes Or higher
GENERIC Display Self-illuminating back-light digital display
GENERIC Housing Material ABS
GENERIC Enclsoure Protection rating IP 66, IP 67, IP 68 Or higher
GENERIC Weight < 250 gram
GENERIC Connectivity interface USB, NA
FEATURES Salient Features Two Levels of alarms for TWA (Time Weighted Average) & STEL (Short Term Exposure Limit), The Set Points are adjustable over entire Range, Calibration due date indication, Data logging, Hand free Operation
ACCESSORIES Accessories in the scope of supply Calibration cup/adaptor/calibration tubing to facilitate calibration locally, Operation Manual
WARRANTY/SERVICE Warranty on Equipment (Months) 12, 24 Or higher
WARRANTY/SERVICE Warranty on Sensor (Months) 12, 24 Or higher
WARRANTY/SERVICE Maximum Time period within which any defects reported be rectified, at the buyer/consignee site, without any extra cost during warranty period of equipment one week ( from reporting of the defect)
OPERATING ENVIRONMENT Minimum Operating Temperature ( degree Celsius) -5
OPERATING ENVIRONMENT Maximum Operating Temperature ( degree Celsius) 50
OPERATING ENVIRONMENT Operating Humidity Up to 90%(Non-Condensing)
GENERAL TECHNICAL REQUIREMENTS (GTR) Other General Requirement a) Agreed to provide Declaration on the cross-sensitivity of sensor with other gasses, to the buyer at the time of supply. b) Agreed to pre despatch inspection of the material by byuer/ buyer's authorized Inspection Agency, if applicable. c) Agreed to provide details regading frequency of calibration as recommendad by OEM or calibration frequency is once in six month whichever is earlier. d) Agreed to provide certificate for area of use ( hazardous area) and Enclosure Protection Rating Certificate by accredited agencies like FM/UL/CENELEC/BASSEFA/ ATEX/CIMFR/IECEx/CSA/SAA/TIIS/INMETRO/CUTR etc. e) Agreed to provide PESO approval Certificate to the buyer at the time of supply. f) Agreed to provide 2 free calibration services per year during warranty period. g) Agreed to provide authorized supplier having valid authorization from OEM. All other details shall be as per ANSI/ISA 92.0.01 to 92.06.01 or equivalent IEC standards(In Case of Reseller). h)Agreed to provide relevant technical literature of the offered instrument with make & model with copy of relevant approval, including sensor specification sheet for sensor used in the instrument.
CALIBRATION CERTIFICATE Calibration Certificate provided Yes
CALIBRATION CERTIFICATE Calibration Certificate issuing authority NABL / ILAC approved agency
TEST REPORT Type of lab which carried out Test of Complete Product to prove the conformity of product as per specification OEM
TEST REPORT Agree to provide all relevant documents Test Reports/supporting documents /reports etc to the buyer at the time of bidding or on demand Yes

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

06-Jul-2026

Extended Deadline

09-Jul-2026, 6:00 pm

Opening Date

09-Jul-2026, 6:30 pm

Similar Tenders

5 found

Hydrogen Sulfide (H2s) Detector (V1)

Indian Coast Guard

📍 DAKSHINA KANNADA, KARNATAKA

⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM
Urgent

Carbon Monoxide (Co) Detector (V1)

Chandrapur Ferro Alloy Plant

📍 CHANDRAPUR, MAHARASHTRA

⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM

Oxygen (O2) Detector (V1)

Directorate Of Purchase And Stores

📍 KHAMMAM, TELANGANA

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM
Urgent

HydroCarbon gas detector

Bharat Petroleum Corporation Ltd

⏰ Deadline: 2 days left
🛒 Type: Goods
View GEM
Urgent

Indian Air Force ECG Electrodes (V2) Tender Bangalore Karnataka 560001 2026

Indian Air Force

📍 BANGALORE, KARNATAKA

Est: ₹17,500
⏰ Deadline: 2 days left
🛒 Type: Goods
View GEM