Bid Publish Date
25-Aug-2026, 11:41 am
Bid End Date
07-Sep-2026, 12:00 pm
Location
Progress
Public procurement opportunity for Central Railway Optical Time Domain Reflectometer (OTDR) (Q3) in THANE, MAHARASHTRA. Quantity: 2 issued by. Submission Deadline: 07-09-2026 12: 00: 00. View full details and respond.
Quantity
2
Bid Type
Single Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Past Performance
20 %
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Optical Time Domain Reflectometer (OTDR) (Q3)
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Thane
Delivery Pincodes
421301
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Ajay Omprakash Sharma | 421301,SENIOR SECTION ENGINEER (TELECOM), MICROWAVE COMPLEX, NEAR SUBHASH CHOWK, NEXT TO OHE DEPOT, MURBAD ROAD, KALYAN WEST. | Thane | Maharashtra | 421301 | 2 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Past Performance
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE | Fiber Compatibility | Single Mode |
| PERFORMANCE | Central Wavelength (nm) | 1310 & 1550 for Single Mode; |
| PERFORMANCE | Wavelength Tolerance (±) | 20.0 Or lower |
| PERFORMANCE | Dynamic range@ Max Wavelength | 45.0 - 50.0 Or higher |
| PERFORMANCE | Event dead zone - Maximum | 0.5 Or lower |
| PERFORMANCE | Attenuation dead zone - Maximum | 3.0 Or lower |
| PERFORMANCE | Maximum Display Distance Range | 256.0 |
| PERFORMANCE | Pulse width Range | 3 to 20000 for Single Mode/Live Fiber Testing |
| PERFORMANCE | Distance Measurement Accuracy (±) | 0.75 Or lower |
| PERFORMANCE | Reflection Detection Accuracy (±) | ± 4 dB for Single Mode or better |
| PERFORMANCE | Sampling points | 256000.0 - 256000.0 Or higher |
| DISPLAY / STORAGE | Display | Colour Display, LCD, Daylight Readable Display, Touch Screen, Backlit Display |
| DISPLAY / STORAGE | Display Size | 7.0 - 12.0 Or higher |
| DISPLAY / STORAGE | Connectivity interface | USB, RJ 45 |
| DISPLAY / STORAGE | Internal Storage OTDR traces | 50000 |
| DISPLAY / STORAGE | External Storage / Memory Stick Slot provided | USB |
| DISPLAY / STORAGE | External Storage Capacity inclusive in the scope of supply | 32 Or higher |
| STABILIZED LIGHT SOURCE | Modulation | CW, 270 Hz, 1 kHz, 2 kHz |
| STABILIZED LIGHT SOURCE | Optical output power | – 6 dBm for Single Mode |
| POWER SOURCE | Power Source | Internal / Removable- Rechargeable Battery |
| POWER SOURCE | Battery Chemistry, if Rechargeable Battery | Li-Ion |
| POWER SOURCE | Voltage of each Battery | 10.8 |
| POWER SOURCE | Battery Capacity (mAh) | 6400 |
| POWER SOURCE | Number of Batteries required for operation | 1 |
| POWER SOURCE | Number of Batteries supplied (Inclusive in the Scope of Supply) | 1 |
| POWER SOURCE | Operating Time per full charge (Minimum) | 12.0 |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Built-in Visual Fault Locator (VFL) / Visual Light Source (VSL) | Yes |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Wave Length Range (VFL/VSL) | 650 nm ± 20 nm |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Output Function (VFL/VSL) | CW |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Maximum Optical output power (Peak) (VFL/VSL) - dBm | − 3 dBm or more |
| VISUAL FAULT LOCATOR (VFL) / VISUAL LIGHT SOURCE (VLS) FOR OTDR | Laser Safety of VFL/VSL as per IEC 60825-1 latest or equivalent international standard | Class 2 |
| POWER METER FOR OTDR | Built-in Power Meter | Yes |
| POWER METER FOR OTDR | Power Meter input port | Dedicated Port on OTDR |
| POWER METER FOR OTDR | Wavelength Range | 850 nm to 1650 nm |
| POWER METER FOR OTDR | Minimum Power measurement range (dBm) | -70.0 - -70.0 Or lower |
| POWER METER FOR OTDR | Maximum Power measurement range (dBm) | 10.0 - 50.0 Or higher |
| POWER METER FOR OTDR | Accuracy (Power Meter) (±) | 0.0 - 0.0 Or lower |
| GENERIC | Connector Tip | PC/UPC |
| GENERIC | Connector / Adapter End | FC |
| GENERIC | OTDR Data Format | .sor |
| SALIENT FEATURES | "Salient Features (Select Applicable Features Only)" | Supports 12 V External Battery |
| ACCESSORIES | Aceesories inclusive in the Scope of Supply (Select included Accessories Only) | Carry Case |
| OPERATING CONDITIONS | Minimum Operating Temperature | -10.0 Or lower |
| OPERATING CONDITIONS | Maximum Operating Temperature | 60.0 Or higher |
| OPERATING CONDITIONS | Maximum Operating Humidity | 95.0 - 95.0 Or higher |
| WARRANTY | WARRANTY | 3, 5 Or higher |
| CERTIFICATION | Availability of Test Reports from Central Govt/ NABL/ ILAC acredited lab to prove confirmity to the Specifications | Yes |
| CERTIFICATION | If Yes, Test Report to be furnished to the Buyer on demand | Yes |