Progress
RAQuantity
630
Bid Type
Two Packet Bid
Public procurement opportunity for Indian Army Provn of OR Living Shelter 20 Men Shelter Parts Only FOR HOCHE, Provn of OR Living Shelter 20 Men Sh in DHEMAJI, ASSAM. Quantity: 630 issued by. Submission Deadline: 26-05-2025 11: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR HOCHE
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR LAMANG
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR KAYING
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR LIMIKING
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR MAJA
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR MANIGONG
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
A Provn of OR Living Shelter 20 Men Shelter Parts Only FOR MANIGONG
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of OR Living Shelter 20 Men Shelter Parts Only FOR TADADEGE
OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A.
Provn of Construction Material for OR Living Shelter 20 Men FOR HOCHE
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Construction Material for OR Living Shelter 20 Men FOR LAMANG
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Construction Material for OR Living Shelter 20 Men FOR KAYING
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Construction Material for OR Living Shelter 20 Men FOR LIMIKING
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Construction Material for OR Living Shelter 20 Men FOR MAJA
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Construction Material for OR Living Shelter 20 Men FOR MANIGONG
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
A Provn of Construction Material for OR Living Shelter 20 Men FOR MANIGONG
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Construction Material for OR Living Shelter 20 Men FOR TADADEGE
Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II.
Provn of Internal Pathway for OR living Shelter 20 Men FOR HOCHE
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Internal Pathway for OR living Shelter 20 Men FOR LAMANG
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Internal Pathway for OR living Shelter 20 Men FOR KAYING
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Internal Pathway for OR living Shelter 20 Men FOR LIMIKING
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Internal Pathway for OR living Shelter 20 Men FOR MAJA
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Internal Pathway for OR living Shelter 20 Men FOR MANIGONG
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
A Provn of Internal Pathway for OR living Shelter 20 Men FOR MANIGONG
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Internal Pathway for OR living Shelter 20 Men FOR TADADEGE
Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III
Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR KAYING
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR MAJA
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG
Provn of Water Dispensor as per tech specification given in Appx J
A Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
B Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
C Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Writing Table as per tech specifications given in Appx E
D Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Chair Writing as per tech specifications given in Appx F
E Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Chair Easy as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Peg Table as per tech specifications given in Appx G
G Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
H Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Double Sleeping Bunk as per tech specifications given in Appx C
A Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Bed side steel locker Double decker as per tech specification given in Appx D
B Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Writing Table as per tech specifications given in Appx E
C Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Chair Writing as per tech specifications given in Appx F
D Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Chair Easy as per tech specifications given in Appx G
E Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Peg Table as per tech specifications given in Appx G
F Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H
G Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE
Provn of Water Dispensor as per tech specification given in Appx J
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR HOCHE
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR HOCHE
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR HOCHE
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LAMANG
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LAMANG
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LAMANG
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR KAYING
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR KAYING
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR KAYING
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LIMIKIMG
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LIMIKIMG
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LIMIKIMG
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MAJA
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MAJA
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MAJA
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG 1
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG 1
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
Provn of Fire Alarm System for OR Living Shelter 20 Men FOR TADADEGE
Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR TADADEGE
Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery
B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR TADADEGE
Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR HOCHE | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 2 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR LAMANG | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 3 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR KAYING | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 4 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR LIMIKING | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 2 | set | adivyanshu.594w | 60 | |
| 5 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR MAJA | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 6 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR MANIGONG | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 7 | A Provn of OR Living Shelter 20 Men Shelter Parts Only FOR MANIGONG | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 8 | Provn of OR Living Shelter 20 Men Shelter Parts Only FOR TADADEGE | OR Living Shelter. Size 12.0m x 6.10m with 1.50m wide front and rear verandah comma three doors comma seven aluminium sliding windows 4x4 comma false ceiling made of 30mm PUF panels comma wall cladding made of 50mm PUF panels comma roof cladding made of 0.6mm PPGI colour coated sheets and three steel trusses made of portal frame structure. Main column with web 300 comma 200 x 5mm thick and flanges of 125 x 8mm thick comma main rafter with web 250 comma 150 x 5mm thick and flanges of 100 x 8 mm thick comma 110 x 8 mm thick and cantilever verandah rafter of same dimension. The three main portal frames are provided at a distance 6.0 mtr centre to centre and interconnected by Z oblique C purlins at spacing all as given in the drawing No LVG 01 comma including erection tool comma seven sheets attached. Tech specifications is as per Appx A. | 1 | set | adivyanshu.594w | 60 | |
| 9 | Provn of Construction Material for OR Living Shelter 20 Men FOR HOCHE | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 10 | Provn of Construction Material for OR Living Shelter 20 Men FOR LAMANG | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 11 | Provn of Construction Material for OR Living Shelter 20 Men FOR KAYING | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 12 | Provn of Construction Material for OR Living Shelter 20 Men FOR LIMIKING | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 2 | set | adivyanshu.594w | 60 | |
| 13 | Provn of Construction Material for OR Living Shelter 20 Men FOR MAJA | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 14 | Provn of Construction Material for OR Living Shelter 20 Men FOR MANIGONG | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 15 | A Provn of Construction Material for OR Living Shelter 20 Men FOR MANIGONG | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 16 | Provn of Construction Material for OR Living Shelter 20 Men FOR TADADEGE | Constr mtrl for OR Living shelter 20 Men. Detailed specification as per Appx B. List of elect items and constr mtrl is as per Annx I and Annx II. | 1 | set | adivyanshu.594w | 60 | |
| 17 | Provn of Internal Pathway for OR living Shelter 20 Men FOR HOCHE | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 18 | Provn of Internal Pathway for OR living Shelter 20 Men FOR LAMANG | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 19 | Provn of Internal Pathway for OR living Shelter 20 Men FOR KAYING | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 20 | Provn of Internal Pathway for OR living Shelter 20 Men FOR LIMIKING | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 48 | sqm | adivyanshu.594w | 60 | |
| 21 | Provn of Internal Pathway for OR living Shelter 20 Men FOR MAJA | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 22 | Provn of Internal Pathway for OR living Shelter 20 Men FOR MANIGONG | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 23 | A Provn of Internal Pathway for OR living Shelter 20 Men FOR MANIGONG | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 24 | Provn of Internal Pathway for OR living Shelter 20 Men FOR TADADEGE | Provn of interlocking paving blocks for pathway as per detailed specifications given as per Appx K and store list as per Annx III | 24 | sqm | adivyanshu.594w | 60 | |
| 25 | Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 26 | A Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 27 | B Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 28 | C Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 29 | D Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 30 | E Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 31 | F Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 32 | G Provn of Furniture for OR Living Shelter 20 Men FOR HOCHE | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 33 | Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 34 | A Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 35 | B Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 36 | C Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 37 | D Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 38 | E Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 39 | F Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 40 | G Provn of Furniture for OR Living Shelter 20 Men FOR LAMANG | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 41 | Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 42 | A Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 43 | B Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 44 | C Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 45 | D Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 46 | E Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 47 | F Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 48 | G Provn of Furniture for OR Living Shelter 20 Men FOR KAYING | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 49 | Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 20 | nos | adivyanshu.594w | 60 | |
| 50 | A Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 20 | nos | adivyanshu.594w | 60 | |
| 51 | B Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Writing Table as per tech specifications given in Appx E | 4 | nos | adivyanshu.594w | 60 | |
| 52 | C Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Chair Writing as per tech specifications given in Appx F | 4 | nos | adivyanshu.594w | 60 | |
| 53 | D Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Chair Easy as per tech specifications given in Appx G | 8 | nos | adivyanshu.594w | 60 | |
| 54 | E Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Peg Table as per tech specifications given in Appx G | 12 | nos | adivyanshu.594w | 60 | |
| 55 | F Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 4 | nos | adivyanshu.594w | 60 | |
| 56 | G Provn of Furniture for OR Living Shelter 20 Men FOR LIMIKING | Provn of Water Dispensor as per tech specification given in Appx J | 4 | nos | adivyanshu.594w | 60 | |
| 57 | Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 58 | A Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 59 | B Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 60 | C Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 61 | D Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 62 | E Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 63 | F Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 64 | G Provn of Furniture for OR Living Shelter 20 Men FOR MAJA | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 65 | Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 66 | A Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 67 | B Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 68 | C Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 69 | D Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 70 | E Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 71 | F Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 72 | G Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 73 | A Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 74 | B Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 75 | C Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 76 | D Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 77 | E Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 78 | F Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 79 | G Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 80 | H Provn of Furniture for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 81 | Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Double Sleeping Bunk as per tech specifications given in Appx C | 10 | nos | adivyanshu.594w | 60 | |
| 82 | A Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Bed side steel locker Double decker as per tech specification given in Appx D | 10 | nos | adivyanshu.594w | 60 | |
| 83 | B Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Writing Table as per tech specifications given in Appx E | 2 | nos | adivyanshu.594w | 60 | |
| 84 | C Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Chair Writing as per tech specifications given in Appx F | 2 | nos | adivyanshu.594w | 60 | |
| 85 | D Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Chair Easy as per tech specifications given in Appx G | 4 | nos | adivyanshu.594w | 60 | |
| 86 | E Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Peg Table as per tech specifications given in Appx G | 6 | nos | adivyanshu.594w | 60 | |
| 87 | F Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Kerosene Heat King Bukhari as per tech specification given in Appx H | 2 | nos | adivyanshu.594w | 60 | |
| 88 | G Provn of Furniture for OR Living Shelter 20 Men FOR TADADEGE | Provn of Water Dispensor as per tech specification given in Appx J | 2 | nos | adivyanshu.594w | 60 | |
| 89 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR HOCHE | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 90 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR HOCHE | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 91 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR HOCHE | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 | |
| 92 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LAMANG | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 93 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LAMANG | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 94 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LAMANG | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 | |
| 95 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR KAYING | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 96 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR KAYING | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 97 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR KAYING | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 | |
| 98 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LIMIKIMG | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 4 | nos | adivyanshu.594w | 60 | |
| 99 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LIMIKIMG | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 4 | nos | adivyanshu.594w | 60 | |
| 100 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR LIMIKIMG | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 4 | nos | adivyanshu.594w | 60 | |
| 101 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MAJA | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 102 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MAJA | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 103 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MAJA | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 | |
| 104 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 105 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 106 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 | |
| 107 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 108 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG 1 | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 109 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR MANIGONG 1 | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 | |
| 110 | Provn of Fire Alarm System for OR Living Shelter 20 Men FOR TADADEGE | Provn of Individual standalone plastic body smoke alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of covering area greater than 40Sqm and actuating an inbuilt alarm with loudness minimum 80 DB. Smoke alarm be powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 111 | A Provn of Fire Alarm System for OR Living Shelter 20 Men FOR TADADEGE | Provn of Individual standalone plastic body heat alarm with adequate provision for fixing on wall oblique ceiling oblique roof. The unit to have sensor capable of detecting fixed temperature of 58 degree celcious and and actuating an inbuilt alarm powered by 9 volt lithium batteries with an arrangement to test the battery and indicator to warn for low battery comma including supply two Nos of battery | 2 | nos | adivyanshu.594w | 60 | |
| 112 | B Provn of Fire Alarm System for OR Living Shelter 20 Men FOR TADADEGE | Fire ball extinguisher of 1.3 Kg weight with suitable provision for wall mounting and cpable of self activating on contact with flames. The unit to be maintainance free comma non toxic comma envoronment friendly and suitable for all type of fires | 2 | nos | adivyanshu.594w | 60 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
26-May-2025, 11:00 am
Opening Date
26-May-2025, 11:30 am
Start
02-Jun-2025, 10:00 am
End
03-Jun-2025, 11:00 am
Duration: 25 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | ********** Under PMA | - | 25-05-2025 16:41:21 | |
| 2 | ********** Under PMA | - | 25-05-2025 20:08:56 | |
| 3 | ********** Under PMA | - | 26-05-2025 10:59:04 | |
| 4 | ********** Under PMA | - | 26-05-2025 10:16:26 | |
| 5 | ********** Under PMA | - | 25-05-2025 15:13:33 | |
| 6 | ********** Under PMA | - | 25-05-2025 16:14:57 | |
| 7 | ********** Under PMA | - | 26-05-2025 10:26:26 | |
| 8 | ********** Under PMA | - | 25-05-2025 20:18:32 | |
| 9 | ********** Under PMA | - | 25-05-2025 20:19:32 | |
| 10 | ********** Under PMA | - | 25-05-2025 21:15:52 | |
| 11 | ********** Under PMA | - | 26-05-2025 10:35:18 | |
| 12 | ********** Under PMA | - | 25-05-2025 20:20:17 | |
| 13 | ********** Under PMA | - | 26-05-2025 10:28:11 | |
| 14 | ********** Under PMA | - | 25-05-2025 20:35:17 | |
| 15 | ********** Under PMA | - | 25-05-2025 20:51:54 | |
| 16 | ********** Under PMA | - | 25-05-2025 20:12:21 |
Key insights about ASSAM tender market
The eligibility requirements include being a registered entity with a proven track record in manufacturing or supplying construction-related products. Interested bidders must demonstrate relevant experience and provide documentation of past projects. Compliance with any governmental regulations and standards pertaining to military supplies is also mandatory.
Bidders must submit relevant certificates verifying compliance with safety and quality standards pertinent to military shelters. This may include ISO certifications, material safety data sheets, and other industry-standard certificates. Documentation proving financial capability and previous successful project execution is also essential.
To register for the submission process, bidders must create an account on the designated tender portal. Registration involves providing essential business details and may require uploading specific documents. Once registered, users can access the tender, download relevant forms, and prepare their bids accordingly.
The technical specifications entail a detailed description of materials, structural requirements, and safety standards that must be adhered to when constructing or supplying the shelter. Bidders should reference the Bill of Quantities (BOQ) for specific guidelines regarding dimensions, insulation, and durability as required within the project.
Yes, there are special provisions in place for Micro, Small, and Medium Enterprises (MSEs) and startups. These provisions facilitate easier entry into the tendering process and may include relaxed eligibility criteria and support for adverse financial conditions, thereby encouraging participation and innovation.
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS