TenderDekho Logo
Closed GEM

Open Tender for 1 size LMA Supraglotic disopsable,LMA Supraglotic disopsable 1point 5 size,2 size LMA Supraglotic d in NEW DELHI, DELHI

Bid Publish Date

05-Dec-2024, 11:04 am

Bid End Date

04-Jan-2025, 9:00 am

EMD

₹80,000

Value

₹1,44,00,000

Generate Docs

Progress

RA
Issue05-Dec-2024, 11:04 am
Reverse Auction28-May-2025, 12:00 pm
Award29-Oct-2025, 1:41 am
Explore all 4 tabs to view complete tender details

Quantity

1140

Category

1 size LMA Supraglotic disopsable

Bid Type

Two Packet Bid

Categories 39

Central Health Service Ministry Of Health And Family Welfare invites bids for 1 size LMA Supraglotic disopsable, LMA Supraglotic disopsable 1point 5 size, 2 size LMA Supraglotic disopsable, size 2 point 5 LMA Supraglotic disopsable, 3 size LMA Supraglotic disopsable, 4 size LMA Supraglotic disopsable, 5 size LMA Supraglotic disopsable, LMA Protector SIZE 3, Protector LMA SIZE 4, Emergency Kit 1 size 3, size 4 Emergency Kit 1, 3 size Emergency Kit 2, 4 size Emergency Kit 3, 5 size Emergency Kit 2, Pelvic Stabilizer, NASAL Atomizer, Small Bronchoscopy Mask, Medium Bronchoscopy Mask, Large Bronchoscopy Mask, Small NIV Mask, Medium NIV Mask, Large NIV Mask, 1 point 5 size LMA Proseal Set Reusable, 2 size LMA Proseal Set Reusable, Reusable 2 point 5 size LMA Proseal Set Reusable, 3 size LMA Proseal Set Reusable, 4 size LMA Proseal Set Reusable, 1 size LMA Proseal Set Reusable, 5 size LMA Proseal Set Reusable in NEW DELHI, DELHI. Quantity: 1140. Submission Deadline: 04-01-2025 09: 00: 00. Submit your proposal before the deadline.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

1 size LMA Supraglotic disopsable , LMA Supraglotic disopsable 1point 5 size , 2 size LMA Supraglotic disopsable , size 2 point 5 LMA Supraglotic disopsable , 3 size LMA Supraglotic disopsable , 4 size LMA Supraglotic disopsable , 5 size LMA Supraglotic disopsable , LMA Protector SIZE 3 , Protector LMA SIZE 4 , Emergency Kit 1 size 3 , size 4 Emergency Kit 1 , 3 size Emergency Kit 2 , 4 size Emergency Kit 3 , 5 size Emergency Kit 2 , Pelvic Stabilizer , NASAL Atomizer , Small Bronchoscopy Mask , Medium Bronchoscopy Mask , Large Bronchoscopy Mask , Small NIV Mask , Medium NIV Mask , Large NIV Mask , 1 point 5 size LMA Proseal Set Reusable , 2 size LMA Proseal Set Reusable , Reusable 2 point 5 size LMA Proseal Set Reusable , 3 size LMA Proseal Set Reusable , 4 size LMA Proseal Set Reusable , 1 size LMA Proseal Set Reusable , 5 size LMA Proseal Set Reusable

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-7181601.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Bill of Quantities (BOQ) 29 Items Sign in for GEM prices

#1

1 size LMA Supraglotic disopsable

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

10 pieces Delivery: 180 days
#2

LMA Supraglotic disopsable 1point 5 size

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

10 pieces Delivery: 180 days
#3

2 size LMA Supraglotic disopsable

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

10 pieces Delivery: 180 days
#4

size 2 point 5 LMA Supraglotic disopsable

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

10 pieces Delivery: 180 days
#5

3 size LMA Supraglotic disopsable

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

50 pieces Delivery: 180 days
#6

4 size LMA Supraglotic disopsable

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

50 pieces Delivery: 180 days
#7

5 size LMA Supraglotic disopsable

The LMA should be Sterile Available with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult

10 pieces Delivery: 180 days
#8

LMA Protector SIZE 3

Sterile Phthalate free Single use 100 percent Silicone material laryngeal mask airway with dynamic curve and elongated cuff to facilitate the upper esophageal seal Recommended maximum intracuff pressure of 60 cm H20 Unique cuff Pilot Technology in built manometry for continuous cuff pressure monitoring facilitates easy constant at a glance accurate adjustment when necessary Allows direct intubation with Dual gastric drainage channel integrated bite block and MR safe Available in size 3 4 5 with intubating ability of ET tube having size ranging from 6 point 5 to 7 point 5 and larger OG tube insertion ability of 16 to 18 FR respectively

15 pieces Delivery: 180 days
#9

Protector LMA SIZE 4

Sterile Phthalate free Single use 100 percent Silicone material laryngeal mask airway with dynamic curve and elongated cuff to facilitate the upper esophageal seal Recommended maximum intracuff pressure of 60 cm H20 Unique cuff Pilot Technology in built manometry for continuous cuff pressure monitoring facilitates easy constant at a glance accurate adjustment when necessary Allows direct intubation with Dual gastric drainage channel integrated bite block and MR safe Available in size 3 4 5 with intubating ability of ET tube having size ranging from 6 point 5 to 7 point 5 and larger OG tube insertion ability of 16 to 18 FR respectively

15 pieces Delivery: 180 days
#10

Emergency Kit 1 size 3

Kit should contain of Reusable LMA with specifications Sterile Soft elongated silicone inflatable cuff and back plate second seal for gastric access to maintain patency of drain tube Has bite block Reusable up to 40 times Withstands an oesophageal pressure up to a median of 58 cm H2O Available with gastric access even in neonatal size starting from 1 to 5 Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should have inflation line with an opening valve during the sterilization to protect the cuff and Bronchial Blocker must contain It must have unique bifurcated Y Lumen endobronchial blocker with 2 distal cuffs The endobronchial blocker should have length of 75cm and size of 7Fr The endobronchial blocker should have the capacity for the following conduits Oxygen administration port Suction port CO2 checking port The endobronchial blocker should come with multiport adaptor with scope lid for introduction of FOB or Video Bronchoscope and suction catheter securement cap to tighten catheter once properly positioned to reduce potential for cuff displacement Should be compatible with 15mm connector for further connecting to Ventilator The endotracheal blocker should have low volume cuffs made of polyurethane providing optimal seal The endobronchial blocker should have radiopaque shaft to provide visibility under X ray and depth markers indicating the depth of insertion

25 pieces Delivery: 180 days
#11

size 4 Emergency Kit 1

Kit should contain of Reusable LMA with specifications Sterile Soft elongated silicone inflatable cuff and back plate second seal for gastric access to maintain patency of drain tube Has bite block Reusable up to 40 times Withstands an oesophageal pressure up to a median of 58 cm H2O Available with gastric access even in neonatal size starting from 1 to 5 Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should have inflation line with an opening valve during the sterilization to protect the cuff and Bronchial Blocker must contain It must have unique bifurcated Y Lumen endobronchial blocker with 2 distal cuffs The endobronchial blocker should have length of 75cm and size of 7Fr The endobronchial blocker should have the capacity for the following conduits Oxygen administration port Suction port CO2 checking port The endobronchial blocker should come with multiport adaptor with scope lid for introduction of FOB or Video Bronchoscope and suction catheter securement cap to tighten catheter once properly positioned to reduce potential for cuff displacement Should be compatible with 15mm connector for further connecting to Ventilator The endotracheal blocker should have low volume cuffs made of polyurethane providing optimal seal The endobronchial blocker should have radiopaque shaft to provide visibility under X ray and depth markers indicating the depth of insertion

25 pieces Delivery: 180 days
#12

3 size Emergency Kit 2

Kit Should consist of Disposable LMA with Specification of The LMA should be SterileAvailable with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult and Emergency Cricothyrotomy Set with Specification of Sterile single use pre assembled emergency cricothyrotomy set comes with conical stainless steel introduction dilator Having pre mounted stopper to prevent the needle from being too deeply inserted which minimises risk of posterior wall perforation The set should also include flexible silicon tube extension with 15 mm connector a scalpel and a pre-assembled unit of one way disposable syringe with the tube flexible flange and attached comport neck band Available in size 2 for paediatric and size 4 for adults

25 pieces Delivery: 180 days
#13

4 size Emergency Kit 3

Kit Should consist of Disposable LMA with Specification of The LMA should be SterileAvailable with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult and Emergency Cricothyrotomy Set with Specification of Sterile single use pre assembled emergency cricothyrotomy set comes with conical stainless steel introduction dilator Having pre mounted stopper to prevent the needle from being too deeply inserted which minimises risk of posterior wall perforation The set should also include flexible silicon tube extension with 15 mm connector a scalpel and a pre-assembled unit of one way disposable syringe with the tube flexible flange and attached comport neck band Available in size 2 for paediatric and size 4 for adults

25 pieces Delivery: 180 days
#14

5 size Emergency Kit 2

Kit Should consist of Disposable LMA with Specification of The LMA should be SterileAvailable with gastric access even in neonatal size starting from 1 to 5 Delivers oropharyngeal leak pressure up to 37 cm H2O and AirForm elongated Cuffs can be inflated to a maximum of 60cm H2O intracuff pressure The LMA should come with a soft and elongated cuff having epiglottic fins with second seal for gastric access to maintain patency of drain tube with Anatomically shaped LMA Evolution curve and fixation tab Has bite block The LMA should be able to insert in minimal mouth opening upto 0 point 75cm in pediatrics and 1point75 cm in adult and Emergency Cricothyrotomy Set with Specification of Sterile single use pre assembled emergency cricothyrotomy set comes with conical stainless steel introduction dilator Having pre mounted stopper to prevent the needle from being too deeply inserted which minimises risk of posterior wall perforation The set should also include flexible silicon tube extension with 15 mm connector a scalpel and a pre-assembled unit of one way disposable syringe with the tube flexible flange and attached comport neck band Available in size 2 for paediatric and size 4 for adults

25 pieces Delivery: 180 days
#15

Pelvic Stabilizer

Product should be 100 percent polyurethane material that is thinner breathable durable and contains moisture wicking capabilities 100% radiolucent One Size Fits All Provide Symmetrical Circumferential Compression and across the width of the belt Be ap

60 pieces Delivery: 180 days
#16

NASAL Atomizer

NASAL Atomizer The intranasal atomozation device should enable a seal to be formed with the nostril and atomized particles of medication to be delivered to the nasal mucosa should have Soft Conical plug to form a seal with the nostril preventing expulsion

50 pieces Delivery: 180 days
#17

Small Bronchoscopy Mask

Bronchoscopy mask for non-invasiv ventilation with nasal port and oral port and nebulization port for aerosol therepy and oxygenation supplementation.

20 pieces Delivery: 180 days
#18

Medium Bronchoscopy Mask

Bronchoscopy mask for non-invasiv ventilation with nasal port and oral port and nebulization port for aerosol therepy and oxygenation supplementation.

25 pieces Delivery: 180 days
#19

Large Bronchoscopy Mask

Bronchoscopy mask for non-invasiv ventilation with nasal port and oral port and nebulization port for aerosol therepy and oxygenation supplementation.

5 pieces Delivery: 180 days
#20

Small NIV Mask

Non Invasive Ventilation Full face mask with Nebulization Port between the expiratory port and the mask leading to higher deposition rate with MDI and Ryles tube adapter should have Angular forehead support which transfers the weight of the mask from the

100 pieces Delivery: 180 days
#21

Medium NIV Mask

Non Invasive Ventilation Full face mask with Nebulization Port between the expiratory port and the mask leading to higher deposition rate with MDI and Ryles tube adapter should have Angular forehead support which transfers the weight of the mask from the

260 pieces Delivery: 180 days
#22

Large NIV Mask

Non Invasive Ventilation Full face mask with Nebulization Port between the expiratory port and the mask leading to higher deposition rate with MDI and Ryles tube adapter should have Angular forehead support which transfers the weight of the mask from the

85 pieces Delivery: 180 days
#23

1 point 5 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

50 pieces Delivery: 180 days
#24

2 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

50 pieces Delivery: 180 days
#25

Reusable 2 point 5 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

50 pieces Delivery: 180 days
#26

3 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

50 pieces Delivery: 180 days
#27

4 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

10 pieces Delivery: 180 days
#28

1 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

10 pieces Delivery: 180 days
#29

5 size LMA Proseal Set Reusable

Made of 100 percent silicone reusable consist of introducer and cuff deflator soft silicone double cuff with non return valve separate tube for orogastric suction buildt in bite block CE or FDA or ISO MARKED

10 pieces Delivery: 180 days

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

31-Dec-2024

Extended Deadline

04-Jan-2025, 9:00 am

Opening Date

04-Jan-2025, 9:30 am

Reverse Auction Schedule

Completed

Start

28-May-2025, 12:00 pm

End

29-May-2025, 12:00 pm

Duration: 24 hours

Reverse Auction Document

✅ RA concluded. Check financial results for final rankings.

Technical Results

S.No Seller Item Date Status
1
**********   Under PMA
-25-12-2024 01:01:43
2
**********   Under PMA
-26-12-2024 11:08:15
3
**********   Under PMA
-03-01-2025 23:24:53

Contract / Result Documents 9

Please sign in or create an account to view contract details and download result documents.

Frequently Asked Questions

Key insights about DELHI tender market

What are the eligibility requirements for the tender GEM/2024/B/5646090?

The eligibility requirements for this tender include being a registered business entity with a minimum average annual turnover of 70 Lakhs. Bidders must have at least 2 years of past performance relevant to supplying medical consumables. Additionally, OEM authorization and compliance documentation are required.

What required certificates need to be submitted for the tender?

Bidders must submit various documents, including:

  • Experience Criteria documents,
  • Past Performance evidence,
  • OEM Annual Turnover Certificates.
    These documents ensure the bidder's capability to deliver quality products effectively.
How can I register for the tender?

Bidders need to register as a vendor on the dedicated online bidding platform. Once registered, they can access and respond to the tender by submitting necessary documents and bids online.

What document formats are accepted for submission?

Only PDF formats are accepted for document submissions related to this tender. Other formats may lead to disqualification, so bidders should ensure their documents meet the required specifications.

What are the technical specifications for the consumables?

The technical specifications include various sizes of LMA Supraglottic disposable items and adhere to established healthcare quality norms. Detailed specifications can be found in the BoQ attached to the tender document.

What quality standards must be met for the consumables?

The quality standards are aligned with medical industry norms, ensuring that all products supplied are safe, effective, and suitable for clinical use. Every bidder must provide proof of compliance with these standards.

Are there compliance requirements for the tender?

Yes, compliance requirements include adherence to the technical specifications provided in the BoQ, quality standards for medical devices, and submission of all necessary documentation to support the bid.

What is the Earnest Money Deposit (EMD) for the tender?

The EMD is set at 80,000 and serves as a deposit to be refunded at the end of the tender process, provided there are no discrepancies in the submissions.

What performance security is required if I win the tender?

Upon successful bid acceptance, the winning bidder may be required to provide a performance security as specified in the tender documents. This security ensures fulfillment of contract obligations.

What are the payment terms for this tender?

Payment terms will be broken down in detail post-award but typically include payment upon successful delivery and acceptance of products.

How will price evaluations be conducted in this tender?

Price evaluations will be based on the lowest priced technically qualified bidders. All bids will be carefully scrutinized according to the specifications and quality standards outlined in the tender documentation.

What submission methods are allowed for the tender?

Bids must be submitted electronically through the designated online portal, along with all required documents formatted as specified.

What key timelines and deadlines should be observed?

Although specific dates may update, it is critical for bidders to note timelines related to the submission of bids, opening of bids, and other relevant actions as outlined in the official tender document.

How is the evaluation and selection process conducted?

The evaluation process consists of assessing the bids based on technical and financial criteria. Successful bidders will be selected based on quality, price, and compliance with all stipulated requirements.

How are bidders notified of the results?

Bidders will be notified of the results through the official platform used for submission. Notification methods will be established according to the registered contact details during the submission process.

What benefits are available for MSEs participating in this tender?

MSEs can avail benefits such as exemption from certain experience requirements and a favorable evaluation process, encouraging their participation in government procurement.

Are there provisions for startups looking to bid?

Yes, startups can benefit from exemptions regarding years of experience. This initiative is part of government efforts to foster startup engagement in the public procurement sector.

Do I need to comply with 'Make in India' policies for this tender?

Bidders are encouraged to comply with 'Make in India' policies, enhancing local content and procurement rules in their submissions, thus promoting domestic manufacturing and supply chains.