Bid Publish Date
17-Aug-2026, 1:12 pm
Bid End Date
27-Aug-2026, 3:00 pm
EMD
₹21,500
Value
₹25,36,174
Location
Progress
A tender has been published for State Bank Of India (sbi) SITC OF 1. 5 TR HI-WALL SPLIT SYSTEMS, SITC OF 2. 0TR CASSETTE TYPE SPLIT SYSTEMS, COPPER REFRIGERANT PIPING for 1. 5TR HI-WALL SPLIT AC, COPPER REFRIGERANT PIPING for 2. 0TR CASSETTE TYPE SPLIT UNITS, DRAIN PIPE, OUTDOOR STAND for 1. 5TR HI-WALL SPLIT AC, OUTDOOR STAND for 2. 0TR CASSETTE TYPE SPLIT UNITS, VOLTAGE STABILIZER FOR 1. 5 TR SPLIT SYSTEMS, VOLTAGE STABILIZER FOR 2. 0 TR CASSETTE SYSTEMS in KOLKATA, WEST BENGAL. Quantity: 574 by. Submission Deadline: 27-08-2026 15: 00: 00. Check eligibility and apply.
Quantity
574
Category
SITC OF 2.0TR CASSETTE TYPE SPLIT SYSTEMS
Bid Type
Two Packet Bid
Bid Validity
30 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
6
OEM Avg. Turnover
20
Past Performance
80 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
SITC OF 1.5 TR HI-WALL SPLIT SYSTEMS , SITC OF 2.0TR CASSETTE TYPE SPLIT SYSTEMS , COPPER REFRIGERANT PIPING for 1.5TR HI-WALL SPLIT AC , COPPER REFRIGERANT PIPING for 2.0TR CASSETTE TYPE SPLIT UNITS , DRAIN PIPE , OUTDOOR STAND for 1.5TR HI-WALL SPLIT AC , OUTDOOR STAND for 2.0TR CASSETTE TYPE SPLIT UNITS , VOLTAGE STABILIZER FOR 1.5 TR SPLIT SYSTEMS , VOLTAGE STABILIZER FOR 2.0 TR CASSETTE SYSTEMS
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Kolkata
Delivery Pincodes
700001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Souvagya Kumar Sahoo | 700001,LHO kolkata, 1 Strand Road, Kolkata | Kolkata | West Bengal | 700001 | 4 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
SITC OF 1.5 TR HI-WALL SPLIT SYSTEMS
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6
SITC OF 2.0TR CASSETTE TYPE SPLIT SYSTEMS
Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS -1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS 1391 as required. Inverter Type Cooling with 5 Star BEE Rating , Minimum value of ISEER 5.6
COPPER REFRIGERANT PIPING for 1.5TR HI-WALL SPLIT AC
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI - WALL SPLIT
COPPER REFRIGERANT PIPING for 2.0TR CASSETTE TYPE SPLIT UNITS
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 TR CASSETTE TYPE SPLIT UNITS
DRAIN PIPE
Supply and fixing of duly insulated 25mm UPVC drain pipe
OUTDOOR STAND for 1.5TR HI-WALL SPLIT AC
Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC.
OUTDOOR STAND for 2.0TR CASSETTE TYPE SPLIT UNITS
Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 TR CASSETTE TYPE SPLIT UNITS.
VOLTAGE STABILIZER FOR 1.5 TR SPLIT SYSTEMS
Supplying, Installation, testing and commissioning of stabliser with Rated 4KVA,Input voltage range 130-260 voltage ,Output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class B type insulation temperature and furnish all test report and certificate.The product with minimum 2 yrs of warranty,Automatic Line Voltage Correctors (Step Type) as per IS-8448 1989
VOLTAGE STABILIZER FOR 2.0 TR CASSETTE SYSTEMS
Supplying, Installation, testing and commissioning of stabliser with Rated 5KVA,Input voltage range 130-260 voltage ,Output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class B type insulation temperature and furnish all test report and certificate.The product with minimum 2 yrs of warranty,Automatic Line Voltage Correctors (Step Type) as per IS-8448 1989
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | SITC OF 1.5 TR HI-WALL SPLIT SYSTEMS | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6 | 4 | set | sbilhokol.buyer76 | 15 | |
| 2 | SITC OF 2.0TR CASSETTE TYPE SPLIT SYSTEMS | Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS -1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS 1391 as required. Inverter Type Cooling with 5 Star BEE Rating , Minimum value of ISEER 5.6 | 19 | set | sbilhokol.buyer76 | 15 | |
| 3 | COPPER REFRIGERANT PIPING for 1.5TR HI-WALL SPLIT AC | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI - WALL SPLIT | 20 | mtr | sbilhokol.buyer76 | 15 | |
| 4 | COPPER REFRIGERANT PIPING for 2.0TR CASSETTE TYPE SPLIT UNITS | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 TR CASSETTE TYPE SPLIT UNITS | 285 | mtr | sbilhokol.buyer76 | 15 | |
| 5 | DRAIN PIPE | Supply and fixing of duly insulated 25mm UPVC drain pipe | 200 | mtr | sbilhokol.buyer76 | 15 | |
| 6 | OUTDOOR STAND for 1.5TR HI-WALL SPLIT AC | Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC. | 4 | set | sbilhokol.buyer76 | 15 | |
| 7 | OUTDOOR STAND for 2.0TR CASSETTE TYPE SPLIT UNITS | Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 TR CASSETTE TYPE SPLIT UNITS. | 19 | set | sbilhokol.buyer76 | 15 | |
| 8 | VOLTAGE STABILIZER FOR 1.5 TR SPLIT SYSTEMS | Supplying, Installation, testing and commissioning of stabliser with Rated 4KVA,Input voltage range 130-260 voltage ,Output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class B type insulation temperature and furnish all test report and certificate.The product with minimum 2 yrs of warranty,Automatic Line Voltage Correctors (Step Type) as per IS-8448 1989 | 4 | set | sbilhokol.buyer76 | 15 | |
| 9 | VOLTAGE STABILIZER FOR 2.0 TR CASSETTE SYSTEMS | Supplying, Installation, testing and commissioning of stabliser with Rated 5KVA,Input voltage range 130-260 voltage ,Output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class B type insulation temperature and furnish all test report and certificate.The product with minimum 2 yrs of warranty,Automatic Line Voltage Correctors (Step Type) as per IS-8448 1989 | 19 | set | sbilhokol.buyer76 | 15 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer