TenderDekho Logo
GEM

Bids are Invited For Attending complaint of EI fan water pump comp light lightening conductor substation etc for sites l in NASHIK, MAHARASHTRA

Bid Publish Date

28-Jun-2025, 5:23 pm

Bid End Date

21-Jul-2025, 11:00 am

EMD

₹1,75,990

Value

₹87,99,508

Progress

Issue28-Jun-2025, 5:23 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

11940

Category

Attending complaint of EI fan water pump comp light lightening conductor substation etc for sites located between 100 KM to 200 KM

Bid Type

Two Packet Bid

Categories 245

SLIDE SWITCH PLATFORM SCALE SLUICE VALVE UNDERGROUND CABLE BUFFER PLATE AXLE ALTERNATOR CONNECTING LEADS COPPER CABLE ACSR POWER CABLE CABBING EQUIPMENTS COMPRESSOR CLINKER GRINDER PIPE PROJECT TUBE AND FITTING DECORATION AIR COOLED ENGINE ELECTRICAL PRODUCTS BUS CABLE WIRING ASSEMBLY LED STREET LIGHT LI-ION BATTERY GEYSER WELDING BRAZING AND SOLDERING SERVICES AGRICULTURAL PUMP STRIP DISCRETE COMPONENTS CABLE DUCT LIGHTENING PROTECTION DEVICE TELECOM EQUIPMENT PUMP SPARE PARTS SOIL EARTH CENTRIFUGAL PUMP CLOTHING ELECTRICAL SPARES SILVER RIVET INSULATORS MECHANICAL EQUIPMENT ACCUMULATOR BLADDERS ELECTRICAL BOXES ELECTRICAL SUBSTATION FIRE EXTINGUISHERS WATER PIPE LINE FIRE WATER LINE MATERIAL UNLOADING PUMPS TRANSPORTATION HARVESTER POWER REFRIGERATION SYSTEM ELECTRICAL REGULATOR CENTRIFUGAL MACHINE ALUMINIUM BOAT BRACKET AIR EXHAUSTER GI PIPE COILED CABLE FLUID MECHANICS EQUIPMENT SOLAR CELLS CONTROL PANEL LFH CABLE BARRIERS PVC CABLE SWITCH BOX PHENOLIC PNEUMATIC PRESSURE GAUGE BALL BEARING VALVES DESICCANTS WHEEL BEARING GATE VALVES NUTS ANIMAL LABORATORY EQUIPMENT BELL CONTROLLER TUBE DRAINAGE ELECTRICAL INSULATORS SCBA AXLE COUNTER WIRE FILTER RETAINERS SOLAR PV PROJECT FUEL PUMP WELLHEAD EQUIPMENT BRONZE PIPE SUBSTATION WORM GEAR STEAM PUMPS SOLAR PHOTOVOLTAIC SYSTEM FILLING RAIN CUT SLIDER VALVES LIGHTING SPLIT CASING PUMP SUMP PUMPS HDPE PIPE MS PIPE LINE VALVE PARTS AND ACCESSORIES AUTOMOTIVE CABLE INSULATED CABLE BOILER VALVE LT OVERHEAD LINE ARM CHAIR PEB UPVC PIPE ALUMINUM FAN BURGLAR ALARM OVERLOAD RELAYS GALVANIZED IRON PIPE SWITCH SUPPLY AGITATORS COPPER WIRE SIMPLEX PUMPS WORM PUMPS AD FILM WATER DISTRIBUTION APPARELS CIRCULAR SAW ANGLE APFC PANEL DELTA STARTER POLYETHYLENE PIPE ARCHERY BOW STRINGS BARITONE HORNS FUSES BUILDING CONSTRUCTION SWITCHES AND RELAY MISCELLANEOUS VALVE PAINTING ANGLE GLOBE VALVES STRUCTURE FABRICATION PTFE WIRE WALL CONSTRUCTION ARNO STARTING CONTACTOR DESERT COOLER BEARINGS CABLE LADDER SWITCH YARD WHEAT FLOUR BEARINGS BUSHINGS AND GEARS AMPS SWITCHING APPARATUS ARC VALVE POWER LINE DISTILLATION INTRUDER ALARM HARDWARE AND FASTENERS JOINTING OF PIPE ELECTRICAL WIRE XLPE CABLE AMPOULE FILLING EQUIPMENT SNG VACUUM CIRCUIT BREAKER WOODEN FLOORING FAN SPARE PARTS INSTRUMENTATION CABLE COATING SERVICES WATER DRAINAGE ELECTRICAL?CONDUIT DEEPWELL PUMPS EARTH LEAKAGE RELAY IRRIGATION PUMPS WATER CONDUCTOR SYSTEM PANEL STOMACHERS BASE PLATE CONDUCTOR CAPACITOR SOCKET JAR DESICCATORS AC PIPES FLEXIBLE CABLE HIGH TENSION PANEL LED LUMINARIES WIRELESS SET SWITCH GEAR TUBE LIGHT EARTH AND STONE HOOK UP WIRES SHIELDED CABLE FOOT VALVE CONTACTORS LABORATORY PRESSES ROLLER BEARING AWM WIRE GL WIRE PUMP VALVES MOUNTING HARDWARE BOLTS MAGNETIC CONTACTOR GASKETS AND SEALS HYDRAULIC MACHINES OVERLOAD RELAY POWER WIRE ELECTRICAL CONDENSER TECHNICAL SERVICES SUMP SOLAR PHOTOVOLTAIC MODULE CABLE LUG BOX OIL PUMP VALVE WATER LEVEL RECORDER FUME HOODS PUMP HOUSE AUTOMATION ERECTION OF STRUCTURAL ELECTRONIC COMPONENTS AND SUPPLIES TURBINE PUMPS SLIDING VANE PUMPS FLUORESCENT LAMP PIPE LAYING BARE CABLE GAS BURNERS ANGLE COCK BACKHOE TRANSITION METALS BOILER MOUNTING VALVE MEGA POWER PROJECT CABLE AXIAL SPLIT PUMPS PLC PANEL FIRE BREATHING APPARATUS STARTER WATER TRANSMISSION MACHINE SUBMERSIBLE PUMP POWER RELAYS RECTIFIERS AMP SWITCH EXCAVATION OSCILLATING PUMPS WATER COOLED ENGINE SOFT STARTER BRICK BUNDI ERECTION OF PIPE WATER PUMP CABLE SUPPLY PUMPING MACHINEY CABLE TRAY EARTH MOVING BUSH CONSTRUCTION VENETIAN BLIND

Public procurement opportunity for Bharat Sanchar Nigam Limited Portal(bsnl) Attending complaint of EI fan water pump comp light lightening conductor substation etc for sites l in NASHIK, MAHARASHTRA. Quantity: 11940 issued by. Submission Deadline: 21-07-2025 11: 00: 00. View full details and respond.

Documents 7

GeM-Bidding-8023768.pdf

Main Document

Other Documents

OTHER

Other Documents

OTHER

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

SPECIAL REPAIR/REPLACEMENT OF FIRE ALARM SYSTEM AND REPAIRS TO INTERNAL ELECTRIFICATION OF RANGE AREA PUMP HOUSE NTS PUMP HOUSE, AF NET SUBSTATION, NTS SUBSTATION, ORC PUMP HOUSE BUILDING AND E/M COMPLAINT CELL (ORC AREA) AT AFS BEGUMPET

E-IN-C BRANCH - MILITARY ENGINEER SERVICES

HYDERABAD, TELANGANA

Posted: 27 October 2025
Closed: 24 November 2025
EPROCURE

Pdg Split AC, Batteries, EI work Fan and fitting etc

N/A

ROHTAK, HARYANA

Closed: 4 November 2025
EPROCURE

REPAIR RENEWAL TO LIGHTENING CONDUCTOR ARRESTOR EARTHING WITH EARTHING STRIPS SURGE PROTECTOR TEST TERMINAL TESTING OF EARTHING ETC AT VARIOUS UNITS UNDER AGE EM OF GE BENGDUBI

E-IN-C BRANCH - MILITARY ENGINEER SERVICES

DARJEELING, WEST BENGAL

Posted: 16 September 2025
Closed: 7 October 2025
EPROCURE

1527-2008CN Passenger Fan,278901155306 Head Gasket,13172402000 Cabin Lifting Pump,F-8264800 Cabin L

Indian Army

BARDHAMAN, WEST BENGAL

Posted: 2 September 2025
Closed: 12 September 2025
GEM

Repairing of motor pump, cartage of m/pump, starter, submersible cable 6 sq mm, 10 sq mm aluminium cable 16 to 35 sq mm, etc. at various sites of Hodal Town and all other works contingent thereto.

N/A

PALWAL, HARYANA

Closed: 4 September 2025
EPROCURE

Bill of Quantities (BOQ) 187 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 Attending complaint of EI fan water pump comp light lightening conductor substation etc for sites located upto 25 KM Attending complaint of EI Fans Pump Comp Lighting Lightening Cond LT MV Panels SS MCB DB SB cables etc for the sites located upto 25KM nothing will be paid extra within 4 month of the first visit 60 job narendra.murlidhar 365
2 Attending complaint of EI fan water pump comp light lightening conductor substation etc located between 25 KM to 50 KM Attending complaint of EI Fans Pump Comp Lighting Lightening Cond LT MV Panels SS MCB DB SB cables etc for sites located between 25 KM to 50 KM from dist HQ nothing will be paid extra within 4 month 120 job narendra.murlidhar 365
3 Attending complaint of EI fan water pump comp light lightening conductor substation etc site located between 50 KM to 100 KM Attending complaint of EI Fans Pump Comp Lighting Lightening Cond LT MV Panels SS MCB DB SB cables etc for sites located between 50 KM to 100KM from dist HQ nothing will be paid extra within 4 month 120 job narendra.murlidhar 365
4 Attending complaint of EI fan water pump comp light lightening conductor substation etc for sites located between 100 KM to 200 KM Attending complaint of EI Fans Pump Comp Lighting Lightening Cond LT MV Panels SS MCB DB SB cables etc for sites located between 100KM to 200KM from dist HQ nothing will be paid extra within 4 month 60 job narendra.murlidhar 365
5 S and D of 1 x 1.5 Sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 1 x 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
6 S and D of 2 x 1.5 Sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 2 x 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
7 S and D of 3 x 1.5 sq mm copper cable in existing steel PVC conduit nd casing caping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Caping and S and D of 3 x 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
8 S and D of 6 x 1.5 sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 6 x 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
9 S and D of 2 x 2.5 sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 2 x 2.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
10 S and D of 3 x 2.5 sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 3 x 2.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
11 S and D of 6 x 2.5 sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 6 x 2.5 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
12 S and D of 2 x 4 sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 2 x 4 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
13 S and D of 3 x 4 sq mm copper cable in existing steel PVC conduit and casing capping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Capping and S and D of 3 x 4 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
14 S and D of 6 x 4 sq mm copper cable in existing steel PVC conduit and casing caping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Caping and S and D of 6 x 4 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
15 S and D of 2 x 6 sq mm copper cable in existing steel PVC conduit and casing caping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Caping and S and D of 2 x 6 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
16 S and D of 3 x 6 sq mm copper cable in existing steel PVC conduit and casing caping Replacement of burnt out or damaged cables from existing surface recessed steel and PVC conduit casing Caping and S and D of 3 x 6 sq mm FRLS PVC insulated copper conductor single core cable etc 120 metre narendra.murlidhar 365
17 Circuit or submain wiring with 2 X 1.5 sq mm plus 1 X 1.5 sq mm Wiring for circuit or submain wiring with 2 x 1.5 sq mm plus 1 x 1.5 sq mm earth of FRLS PVC insulated copper conductor single core cable in surface or recessed medium class PVC conduit as reqd 120 metre narendra.murlidhar 365
18 Circuit or submain wiring with 2 X 2.5 sq mm plus 1 X 2.5 sq mm Wiring for circuit or submain wiring with 2 x 2.5 sq mm plus 1 x 2.5 sq mm earth of FRLS PVC insulated copper conductor single core cable in surface or recessed medium class PVC conduit as reqd 120 metre narendra.murlidhar 365
19 Circuit or submain wiring with 2 X 4 sq. mm plus 1 X 4 sq mm Wiring for circuit or submain wiring with 2 x 4 sq mm plus 1 x 4 sq mm earth of FRLS PVC insulated copper conductor single core cable in surface or recessed medium class PVC conduit as reqd 120 metre narendra.murlidhar 365
20 S and F of 20 mm medium class PVC conduit surface or recess Replacement with S and F of 20 mm sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as reqd 80 metre narendra.murlidhar 365
21 S and F of 25 mm medium class PVC conduit surface or recess Replacement with S and F of 25 mm sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as reqd 80 metre narendra.murlidhar 365
22 S and F of 32 mm medium class PVC conduit surface or recess. Replacement with S and F of 32 mm sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as reqd 80 metre narendra.murlidhar 365
23 Providing and fixing 20 mm x 12 mm Casing Capping Replacement with Providing and fixing 20 mm x 12 mm following size of Heavy duty PVC Casingand Capping alongwith all accessories etc complete as required 120 metre narendra.murlidhar 365
24 Providing and fixing 25 mm x 16 mm Casing Capping Replacement with Providing and fixing 25 mm x 16 mm following size of Heavy duty PVC Casing and Capping alongwith all accessories etc complete as required 120 metre narendra.murlidhar 365
25 Providing and fixing 32 mm x 16 mm Casing Capping Replacement with Providing and fixing 32 mm x 16 mm following size of Heavy duty PVC Casing and Capping alongwith all accessories etc complete as required 120 metre narendra.murlidhar 365
26 S and F metal box of sizes 75 mm x 75 mm x 60 mm on surface or in recess Supplying and fixing metal box of sizes 75 mm x 75 mm x 60 mm deep nominal size on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd 70 each narendra.murlidhar 365
27 S and F metal box of sizes 150 mm x 75 mm x 60 mm on surface or in recess Supplying and fixing metal box of sizes 150 mm X 75 mm X 60 mm deep nominal size on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd 70 each narendra.murlidhar 365
28 S and F metal box of sizes 180 mm X 100 mm X 60 mm on surface or in recess Supplying and fixing metal box of size 180 mm X 100 mm X 60 mm deep nominal size on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd 70 each narendra.murlidhar 365
29 Supplying and Fixing 1 or 2 Module 75mmX75mm GI Box in recess Supplying and fixing 1 or 2 Modules 75mm x 75mm size GI box along with modular base and cover plate for modular switches in recess etc as required 80 each narendra.murlidhar 365
30 Supplying and Fixing 3 Module 100mm X 75mm GI Box in recess Supplying and fixing 3 Modules 100 mm X 75mm size GI box along with modular base and cover plate for modular switches in recess etc as required 80 each narendra.murlidhar 365
31 Supplying and Fixing 4 Module 125mm X 75mm GI Box in recess Supplying and fixing 4 Modules 125 mm x 75mm size GI box along with modular base and cover plate for modular switches in recess etc as required 80 each narendra.murlidhar 365
32 Supplying and Fixing 6 Module 200 mm X 75mm G.I. Box in recess Supplying and fixing 6 Modules 200 mm x 75mm size GI box along with modular base and cover plate for modular switches in recess etc as required 80 each narendra.murlidhar 365
33 Supplying and Fixing 8 Module 125 mm X 125 G.I. Box in recess Supplying and fixing 8 Modules 125mm X 125mm size GI box along with modular base and cover plate for modular switches in recess etc as required 80 each narendra.murlidhar 365
34 Supplying and Fixing 12 Module 200 mm X 150 G.I. Box in recess. Supplying and fixing 12 Modules 200mm X 150mm size GI box along with modular base and cover plate for modular switches in recess etc as required. 80 each narendra.murlidhar 365
35 Supplying and fixing 1 or 2 Module Modular base and cover plate Supplying and fixing 1 or 2 Module Modular base and cover plate on existing modular metal boxes etc. as required. 80 each narendra.murlidhar 365
36 Supplying and fixing 3 Module Modular base and cover plate. Supplying and fixing 3 Module Modular base and cover plate on existing modular metal boxes etc. as required. 80 each narendra.murlidhar 365
37 Supplying and fixing 4 Module Modular base and cover plate. Supplying and fixing 4 Module Modular base and cover plate on existing modular metal boxes etc. as required. 80 each narendra.murlidhar 365
38 Supplying and fixing 6 Module Modular base and cover plate. Supplying and fixing 6 Module Modular base and cover plate on existing modular metal boxes etc. as required. 80 each narendra.murlidhar 365
39 Supplying and fixing 8 Module Modular base and cover plate. Supplying and fixing 8 Module Modular base and cover plate on existing modular metal boxes etc. as required. 80 each narendra.murlidhar 365
40 Supplying and fixing 12 Module Modular base and cover plate. Supplying and fixing 12 Module Modular base and cover plate on existing modular metal boxes etc. as required. 80 each narendra.murlidhar 365
41 Replacement with 5 or 6 amp switch piano type. Replacement with 5 or 6 amp switch piano type on the existing switch box or cover including connections etc. as required. 200 each narendra.murlidhar 365
42 Replacement with 2 way 5 or 6 amps switch Piano type. Replacement with 2 way 5 or 6 amps switch Piano type on the existing switch box or cover including connections etc. as required. 80 each narendra.murlidhar 365
43 Replacement with 15 or 16 amp switch Piano type. Replacement with 15 or 16 amp switch Piano type on the existing switch box or cover including connections etc. as required. 200 each narendra.murlidhar 365
44 Replacement with 3 pin 5 or 6 amp socket outlet Piano type. Replacement with 3 pin 5 or 6 amp socket outlet Piano type on the existing switch box or cover including connections etc. as required. 200 each narendra.murlidhar 365
45 Replacement with 6 pin 15 or 16 amp socket outlet Piano type. Replacement with 3 pin 15 or 16 amp switch Piano type on the existing switch box or cover including connections etc. as required. 200 each narendra.murlidhar 365
46 Replacement with Telephone socket outlet Piano type. Replacement with Telephone socket outlet on the existing switch box or cover including connections etc. as required. 30 each narendra.murlidhar 365
47 Replacement with TV antenna socket outlet Piano type. Replacement with TV antenna socket outlet Piano type on the existing switch box or cover including connections etc. as required. 30 each narendra.murlidhar 365
48 Replacement with Bell push piano type Replacement with Bell push piano type on the existing switch box or cover including connections etc. as required. 40 each narendra.murlidhar 365
49 Replacement with Electronic fan regulator 100 Watt step type etc. Replacement with Electronic fan regulator 100 Watt step type etc. on the existing switch box or cover including connections etc. as required. 60 each narendra.murlidhar 365
50 Replacement with 5 or 6 amps switch modular type. Replacement with 5 or 6 amps switch modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 200 each narendra.murlidhar 365
51 Replacement with 2 way 5 or 6 amps switch modular type. Replacement with 2 way 5 or 6 amps switch modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 60 each narendra.murlidhar 365
52 Replacement with 15 or 16 amp switch modular type Replacement with 15 or 16 amp switch modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 200 each narendra.murlidhar 365
53 Replacement with 3 pin 5 or 6 amp socket outlet modular type Replacement with 3 pin 5 or 6 amp socket outlet modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 200 each narendra.murlidhar 365
54 Replacement with 6 pin 15 or 16 amp socket outlet modular type. Replacement with 6 pin 15 or 16 amp socket outlet modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 200 each narendra.murlidhar 365
55 Replacement with Telephone socket outlet modular type. Replacement with Telephone socket outlet modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 30 each narendra.murlidhar 365
56 Replacement with TV antenna socket outlet type. Replacement with TV antenna socket outlet type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 30 each narendra.murlidhar 365
57 Replacement with Bell push modular type. Replacement with Bell push modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 40 each narendra.murlidhar 365
58 Replacement with Two module stepped type electronic fan regulator Replacement with Two module stepped type electronic fan regulator modular type on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 60 each narendra.murlidhar 365
59 Replacement with Supplying and fixing 3 pin 5 amp ceiling rose Replacement with Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box or wooden block including connection etc as required. 100 each narendra.murlidhar 365
60 Replacement with Supplying and fixing brass batten or angle holder Replacement with Supplying and fixing brass batten or angle holder including connection etc. as required. 120 each narendra.murlidhar 365
61 Replacement with Supplying and fixing call bell or buzzer Replacement with Supplying and fixing call bell or buzzer suitable for single phase 230 volts complete as required. 80 each narendra.murlidhar 365
62 Replacement of faulty flurescent tube light starter 0 to 40 Watt 220 to 240 V AC Replacement of faulty flurescent tube light starter 0 to 40 Watt 220 to 240 V AC including Testing commsissioing etc complete as required . 60 each narendra.murlidhar 365
63 Replacement with Supplying and fixing of 5 A to 32A rating Single pole MCB. Replacement with Supplying and fixing of 5 A to 32A rating Single pole 240 or 415 volts C curve MCB suitable for inductive load in the existing MCB DB etc Complete as reqd. 40 each narendra.murlidhar 365
64 Replacement with Supplying and fixing of 5 A to 32A rating SPN MCB Replacement with Supplying and fixing of 5 A to 32A rating Single pole and neutral 240 or 415 volts C curve MCB suitable for inductive load in the existing MCB DB etc Complete as reqd. 40 each narendra.murlidhar 365
65 Replacement with Supplying and fixing of 5A to 32A rating DP MCB Replacement with Supplying and fixing of 5 A to 32A rating double pole 240 or 415 volts C curve MCB suitable for inductive load in the existing MCB DB etc Complete as reqd. 40 each narendra.murlidhar 365
66 Replacement with Supplying and fixing of 5 A to 32A rating TP MCB Replacement with Supplying and fixing of 5 A to 32A rating Triple pole 240 or 415 volts C curve MCB suitable for inductive load in the existing MCB DB etc Complete as reqd. 40 each narendra.murlidhar 365
67 Replacement with Supplying and fixing of 5 A to 32A rating TPN MCB Replacement with Supplying and fixing of 5 A to 32A rating Triple pole and neutral 240 or 415 volts C curve MCB suitable for inductive load in the existing MCB DB etc Complete as reqd. 40 each narendra.murlidhar 365
68 Replacement with Supplying and fixing of 40 amps 4 pole 415 volts Isolator Replacement with Supplying and fixing of 40 amps 4 pole 415 volts Isolator in the existing MCB DB rating complete with connections testing and commissioning etc. as required. 30 each narendra.murlidhar 365
69 Replacement with Supplying and fixing of 63 amps 4 pole 415 volts Isolator Replacement with Supplying and fixing of 63 amps 4 pole 415 volts Isolator in the existing MCB DB rating complete with connections testing and commissioning etc. as required. 30 each narendra.murlidhar 365
70 Replacement with Supplying and fixing of 100 amp 4 pole 415 volts Isolator Replacement with Supplying and fixing of 100 amp 4 pole 415 volts Isolator in the existing MCB DB rating complete with connections testing and commissioning etc. as required. 30 each narendra.murlidhar 365
71 Replacement with Supplying and fixing of 40 amps SP and N RCCB Replacement with Supplying and fixing of 40 amps SP and N RCCB Having Sensitivity 300 milliamperes in the existing MCB DB rating complete with connections testing and comm. etc. as reqd. 30 each narendra.murlidhar 365
72 Supplying and fixing with LED type Tube light fitting 20 to 28 watt Replacement of faulty batten tube light from the existing location and Supplying and fixing with LED type Tube light fitting 20 to 28 watt including testing commissioning etc complete as reqd 250 each narendra.murlidhar 365
73 Rewinding of Ceiling fan upto 1400 mm sweep Rewinding of Ceiling fan upto 1400 mm sweep including replacement of worn out ball bearing Shaff Bush capacitor oiling greasing varnishing taping insulation testing commisioning as reqd. 20 each narendra.murlidhar 365
74 Rewinding of Wall fan upto 450 mm sweep Rewinding of Wall fan upto 450 mm sweep including replacement of worn out ball bearing Shaft Bush capacitor oiling greasing varnishing taping insulation testing commisioning as reqd. 20 each narendra.murlidhar 365
75 Rewinding of Exhaust fan upto 450 mm sweep Rewinding of Exhaust fan upto 450 mm sweep including replacement of worn out ball bearing Shaft Bush capacitor oiling greasing varnishing taping insulation testing commisioning as reqd. 20 each narendra.murlidhar 365
76 Rewinding of Pedestal fan upto 450 mm sweep Rewinding of Pedestal fan upto 450 mm sweep including replacement of worn out ball bearing Shaft Bush capacitor oiling greasing varnishing taping insulation testing commisioning as reqd. 20 each narendra.murlidhar 365
77 Supplying and fixing high performance of 45 Watts LED street light Replacement of street light with Supplying and fixing high performance of 45 Watts LED street light including connections with 1.5 sq mm copper wiring from existing pole box etc complete as reqd. 30 each narendra.murlidhar 365
78 Supplying and Fixing 38mm dia G.I. pipe 0.9 mtr length bracket Supplying and Fixing 38mm dia G.I. pipe 0.9 mtr length bracket with MS clamp and fixing arrangement on existing Compound light pole etc complete as required. 10 each narendra.murlidhar 365
79 Replacement of pole junction box with Supplying and fixing of 240 mm x 130mm x 100 mm size of FRP Replacement of pole junction box with Supplying and fixing of 240 mm x 130mm x 100 mm size of FRP rectangular junction box and 6A rating SP MCB necessary hardware fixing arrangement etc as reqd. 10 each narendra.murlidhar 365
80 Providing and fixing of lightning conductor finial. Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long G.I. tube having single prong at top with 85 mm dia 6 mm thick G.I. base plate including holes etc. as reqd. 20 each narendra.murlidhar 365
81 Jointing copper or G.I. tape with another copper or G I tape Jointing copper or G.I. tape with another copper or G I tape base of the finial or any other metallic object by riveting or nut bolting sweating and soldering etc as required. 20 each narendra.murlidhar 365
82 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. For horizontal run 30 metre narendra.murlidhar 365
83 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 30 metre narendra.murlidhar 365
84 Repairing rewinding of 1 HP capacity centrifugal pump Repairing rewinding of 1 HP capacity centrifugal pump set lncluding greasing varnishing replacement of faulty components like bearings nut bolts gland packing transportation etc as reqd. 20 each narendra.murlidhar 365
85 Repairing rewinding of 2 HP capacity centrifugal pump Repairing rewinding of 2 HP capacity centrifugal pump set lncluding greasing varnishing replacement of faulty components like bearings nut bolts gland packing transportation etc as reqd. 20 each narendra.murlidhar 365
86 Repairing rewinding of 3 HP capacity centrifugal pump set Repairing rewinding of 3 HP capacity centrifugal pump set lncluding greasing varnishing replacement of faulty components like bearings nut bolts gland packing transportation etc as reqd. 20 each narendra.murlidhar 365
87 Repairin rewinding of 5 HP capacity centrifugal pump set Repairing rewinding of 5 HP capacity centrifugal pump set lncluding greasing varnishing replacement of faulty components like bearings nut bolts gland packing transportation etc as reqd. 20 each narendra.murlidhar 365
88 Repairing rewinding of 1.5 HP capacity Submersible Pumpset Repairing rewinding of 1.5 HP capacity Submersible Pumpset including removing from borewell greasingnvarnishingn replacement of faulty components like motor Bush nut bolts complete as required 20 each narendra.murlidhar 365
89 Repairing rewinding of 2 HP capacity Submersible Pumpset Repairing rewinding of 2 HP capacity Submersible Pumpset including removing from borewell greasing varnishing replacement of faulty components like motor Bush nut bolts complete as required 20 each narendra.murlidhar 365
90 Repairing rewinding of 3 HP capacity Submersible Pumpset Repairing rewinding of 3 HP capacity Submersible Pumpset including removing from borewell greasing varnishing replacement of faulty components like motor Bush nut bolts complete as required 20 each narendra.murlidhar 365
91 Repairing rewinding of 5 HP capacity Submersible Pumpset Repairing rewinding of 5 HP capacity Submersible Pumpset including removing from borewell greasing varnishing replacement of faulty components like motor Bush nut bolts complete as required 20 each narendra.murlidhar 365
92 SITC of submersible pumpset of 2 HP Water filled SITC of submersible pump set of 2 HP water filled capacity for 150 mm 6 inch borewell and opeation on 3 Ph 415 V 50 Hz with Max head of 175 meters in the existing borewell etc complete as required. 10 each narendra.murlidhar 365
93 SITC of submersible pumpset of 4 HP water filled SITC of submersible pumpset of 4 HP water filled capacity for 150 mm 6 inch borewell and opeation on 3 Ph 415 volts 50 Hz with Max head of 248 meters in the existing borewell etc complete as reqd. 10 each narendra.murlidhar 365
94 Lifting and Lowing of Submersible or borewell Pump upto 5 HP alongwith GI pipe Lifting and Lowing of Submersible or borewell Pump upto 5 HP alongwith G.I. Pipe cable etc by using required T and P including all types of interconnections testing commissioning etc as required. 10 job narendra.murlidhar 365
95 Lifting and Lowing of Submersible or borewell Pump upto 5 HP alongwith HDPE pipe Lifting and Lowing of Submersible or borewell Pump upto 5 HP alongwith HDPE Pipe cable etc by using required T and P including all types of interconnections testing commissioning etc as required 10 job narendra.murlidhar 365
96 Repairing rewinding of 2 HP Sump Pump set Repairing rewinding of 2 HP Sump Pump set including greasing varnishing replacement of motor Bush nut bolts and gland packing Transportation Loading unloading Testing Comm. etc as required. 10 each narendra.murlidhar 365
97 Repairing rewinding of 3 HP Sump Pump set Repairing rewinding of 3 HP Sump Pump set including greasing varnishing replacement of motor Bush nut bolts and gland packing Transportation Loading Unloading testing Comm. etc as required. 10 each narendra.murlidhar 365
98 Repairing rewinding of 5 HP Sump Pump Repairing rewinding of 5 HP Sump Pump set including greasing varnishing replacement of motor Bush nut bolts and gland packing Transportation Loading Unloading Testing Comm. etc as required. 10 each narendra.murlidhar 365
99 Replacement of faulty foot valve of size 40 mm dia Replacement of faulty foot valve of size 40 mm dia heavy duty made up of Brass with all accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
100 Replacement of faulty foot valve of size 50 mm dia Replacement of faulty foot valve of size 50 mm dia heavy duty made up of Brass with all accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
101 Replacement faulty Gate valve with brass forged or Gun metal valve of 20 mm dia Replacement faulty Gate valve with brass forged or Gun metal valve of 20 mm dia size heavy duty with all fixing accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
102 Replacement faulty Gate valve with brass forged or Gun metal valve of 40 mm dia Replacement faulty Gate valve with brass forged or Gun metal valve of 40 mm dia size heavy duty with all fixing accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
103 Replacement faulty Gate valve with brass forged or Gun metal valve of 50 mm dia Replacement faulty Gate valve with brass forged or Gun metal valve of 50 mm dia size heavy duty with all fixing accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
104 Replacement of NRV with new NRV made up of brass of size 40 mm dia Replacement of faulty NRV with new NRV made up of brass of size 40 mm dia with all fixing accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
105 Replacement of NRV with new NRV made up of brass of size 50 mm dia Replacement of faulty NRV with new NRV made up of brass of size 50 mm dia with all fixing accessories including testing commissioning etc complete as required. 10 each narendra.murlidhar 365
106 Supplying and fixing 20 mm dia B class Medium G.I pipe Supplying and fixing 20 mm dia B class Medium G.I pipe for Suction and dischange line of water pump with all fixing accessories including Testing and commissioning etc complete as reqd. 60 metre narendra.murlidhar 365
107 Supplying and fixing 40 mm dia B class Medium G.I pipe Supplying and fixing 40 mm dia B class Medium G.I pipe for Suction and dischange line of water pump with all fixing accessories including Testing and commissioning etc complete as reqd. 60 metre narendra.murlidhar 365
108 Supplying and fixing 50 mm dia B class Medium G.I pipe Supplying and fixing 50 mm dia B class Medium G.I pipe for Suction and dischange line of water pump with all fixing accessories including Testing and commissioning etc complete as reqd. 60 metre narendra.murlidhar 365
109 Supplying and fixing 20 mm dia heavy duty UPVC pipe Supplying and fixing 20 mm dia heavy duty UPVC pipe for Suction and dischange for water pumps with all fixing accessories including testing commissioning etc complete as required. 60 metre narendra.murlidhar 365
110 Supplying and fixing 40 mm dia heavy duty UPVC pipe Supplying and fixing 40 mm dia heavy duty UPVC pipe for Suction and dischange for water pumps with all fixing accessories including testing commissioning etc complete as required. 60 metre narendra.murlidhar 365
111 Supplying and fixing 50 mm dia heavy duty UPVC pipe Supplying and fixing 50 mm dia heavy duty UPVC pipe for Suction and dischange for water pumps with all fixing accessories including testing commissioning etc complete as required. 60 metre narendra.murlidhar 365
112 Replacement 3 Pole Power Contactors type MNX 12 Replacement faulty 3 Pole Power Contactors type MNX 12 in existing Panels including testing commisioning etc complate as required. 10 each narendra.murlidhar 365
113 Replacement 3 Pole Power Contactors type MNX22 Replacement faulty 3 Pole Power Contactors MNX 22 in existing Panels including testing commisioning etc complete as required. 10 each narendra.murlidhar 365
114 Replacement of mounting Add on Aux. contact block suitable for 9 A to 30 A Replacement of mounting Add on Aux. contact block suitable for 9 A to 30 A having 02 NO. and 02 NC including testing commisioning etc complete as required. 10 each narendra.murlidhar 365
115 Replacement of Thermal overload relay suitable for MNX contactor Range from 0.2 A to 23 A Replacement of Thermal overload relay directly mounted MN suitable for MNX contactor built in single phase protection Auto and manual reset mode Operating Range from 0.2 A to 23 A etc as reqd. 10 each narendra.murlidhar 365
116 Supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1KV grade Supplying of 3 x 2.5 sq. mm PVC insulated and PVC sheathed or XLPE steel armored aluminum conductor UG power cable of 1.1KV grade etc complete as reqd. 80 metre narendra.murlidhar 365
117 Supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1KV grade Supplying of 4 x 16 sq. mm PVC insulated and PVC sheathed or XLPE steel armored aluminum conductor UG power cable of 1.1KV grade etc complete as reqd. 80 metre narendra.murlidhar 365
118 Supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1KV grade Supplying of 3.5 x 35 sq. mm PVC insulated and PVC sheathed or XLPE steel armored aluminum conductor UG power cable of 1.1KV grade etc complete as reqd. 80 metre narendra.murlidhar 365
119 Laying of one no. cable of 1.1 KV grade and size upto 35 sq. mm direct in ground Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade and size upto 35 sq. mm direct in ground including excavation sand cushioning refilling etc as reqd 80 metre narendra.murlidhar 365
120 Laying of one no. cable of 1.1 KV grade and size above 35 upto 95 sq. mm direct in ground Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade and size above 35 sq. mm and upto 95 sq. mm direct in ground including excavation refilling etc as reqd 80 metre narendra.murlidhar 365
121 Laying of one no. cable of 1.1 KV grade and size above 95 upto 185 sq. mm direct in ground Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade and size Above 95 sq. mm and upto 185 sq. mm direct in ground including excavation refilling etc as reqd 80 metre narendra.murlidhar 365
122 Laying of one no. cable of 1.1 KV grade and size upto 35 sq.mm on cable tray Removing of faulty or burnt cable and Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade size upto 35 sq. mm on cable tray as required. 80 metre narendra.murlidhar 365
123 Laying of one no. cable of 1.1 KV grade and size above 35 upto 95 sq. mm on cable tray Removing of faulty or burnt cable and Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade size above 35 sq.mm and upto 95 sq.mm on cable tray as reqd. 80 metre narendra.murlidhar 365
124 Laying of one no. cable of 1.1 KV grade and size above 95 upto 185 sq. mm on cable tray Removing of faulty or burnt cable and Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade size above 95 sq. mm and upto 185 sq. mm on cable tray as reqd 80 metre narendra.murlidhar 365
125 Laying of one no. cable of 1.1 KV grade and size upto 35 sq. mm in existing RCC or HUME or METAL pipe Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size upto 35 sq. mm in the existing RCC or HUME or METAL pipe as required. 80 metre narendra.murlidhar 365
126 Laying of one no. cable of 1.1 KV grade and size above 35 upto 95 sq. mm in existing RCC or HUME or METAL pipe Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 35 sq. mm and upto 95 sq. mm in the existing RCC or HUME or METAL pipe as required. 80 metre narendra.murlidhar 365
127 Laying of one no. cable of 1.1 KV grade and size above 95 upto 185 sq. mm in existing RCC or HUME or METAL pipe Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 95 sq. mm and upto 185 sq. mm in the existing RCC or HUME or METAL pipe as required. 80 metre narendra.murlidhar 365
128 Laying of one no. cable of 1.1 KV grade and size upto 35 sq. mm in existing masonry open duct Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm in the existing masonry open duct as required. 80 metre narendra.murlidhar 365
129 Laying of one no. cable of 1.1 KV grade and size above 35 upto 95 sq. mm in existing masonry open duct Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 35 sq. mm and upto 95 sq. mm in the existing masonry open duct as required. 80 metre narendra.murlidhar 365
130 Laying of one no. cable of 1.1 KV grade and size above 95 upto 185 sq. mm in existing masonry open duct Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 95 sq. mm and upto 185 sq. mm in the existing masonry open duct as required. 80 meter narendra.murlidhar 365
131 Laying of one no. cable of 1.1 KV grade and size upto 35 sq. mm on wall surface Removing of faulty or burnt out cable and Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size upto 35 sq. mm on wall surface as required. 80 metre narendra.murlidhar 365
132 Laying of one no. cable of 1.1 KV grade and size above 35 upto 95 sq. mm on wall surface Removing of faulty or burnt cable and Laying and fixing of one No. PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 35 sq.mm and upto 95 sq.mm on wall surface as reqd. 80 metre narendra.murlidhar 365
133 Laying of one no. cable of 1.1 KV grade and size above 95 upto 185 sq. mm on wall surface Removing of faulty or burnt cable and Laying and fixing of one No.PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of size above 95 sq.mm and upto 185 sq.mm on wall surface as reqd. 80 meter narendra.murlidhar 365
134 S and M end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
135 S and M end termination with brass compression gland and aluminium lugs for 2 x 10 sq.mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 2 x 10 sq.mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
136 S and M end termination with brass compression gland and aluminium lugs for 2 x 16 sq.mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 2 x 16 sq.mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
137 S and M end termination with brass compression gland and aluminium lugs for 2 x 25 sq.mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 2 x 25 sq.mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
138 S and M end termination with brass compression gland and aluminium lugs for 3 x 16 sq.mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3 x 16 sq.mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
139 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 25 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 25 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
140 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 35 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 35 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
141 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 50 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 50 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
142 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 70 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 70 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
143 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 95 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 95 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
144 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 120 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X120 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
145 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 150 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 150 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
146 S and M end termination with brass compression gland and aluminium lugs for 3.5 X 185 sq. mm Al Cable. Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 185 sq. mm of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as reqd. 80 set narendra.murlidhar 365
147 Replacement of burnt out aluminium lugs for 2 x 6 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 2 x 6 sq.mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
148 Replacement of burnt out aluminium lugs for 2 x 10 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 2 x 10 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
149 Replacement of burnt out aluminium lugs for 2 x 16 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 2 x 16 sq.mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
150 Replacement of burnt out aluminium lugs for 2 x 25 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 2 x 25 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
151 Replacement of burnt out aluminium lugs for 3 x 16 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3 x 16 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
152 Replacement of burnt out aluminium lugs for 3.5 X 25 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 25 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required. 40 set narendra.murlidhar 365
153 Replacement of burnt out aluminium lugs for 3.5 X 35 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 35 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
154 Replacement of burnt out aluminium lugs for 3.5 X 50 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 50 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
155 Replacement of burnt out aluminium lugs for 3.5 X 70 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 70 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
156 Replacement of burnt out aluminium lugs for 3.5 X 95 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 95 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
157 Replacement of burnt out aluminium lugs for 3.5 X 120 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 120 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
158 Replacement of burnt out aluminium lugs for 3.5 X 150 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 150 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
159 Replacement of burnt out aluminium lugs for 3.5 X 185 sq.mm aluminium conductor cable. Replacement of faulty or burnt out aluminium lugs for 3.5 x 185 sq. mm size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade etc complete as required 40 set narendra.murlidhar 365
160 Connection with copper link with 10 Sq. mm Single Core FRLS Copper PVC Insulated Flexible Cable Connection with copper link with 10 Sq. mm Single Core FRLS Copper PVC Insulated Flexible Cable for voltage grade upto 1100 V with copper lug on both end and length appx 0.5 mtr etc as reqd 30 job narendra.murlidhar 365
161 Connection with copper link with 16 Sq. mm Single Core flexible cable . Connection with copper link with 16 Sq. mm Single Core FRLS Copper PVC Insulated Flexible Cable for voltage grade upto 1100 V with copper lug on both end and length appx 0.5 mtr etc as reqd 30 job narendra.murlidhar 365
162 Connection with copper link with 25 Sq. mm Single Core flexible cable . Connection with copper link with 25 Sq. mm Single Core FRLS Copper PVC Insulated Flexible Cable for voltage grade upto 1100 V with copper lug on both end and length appx 0.5 mtr etc as reqd 30 job narendra.murlidhar 365
163 Connection with copper link with 35 Sq. mm Single Core flexible cable . Connection with copper link with 35 Sq. mm Single Core FRLS Copper PVC Insulated Flexible Cable for voltage grade upto 1100 V with copper lug on both end and length appx 0.5 mtr etc as reqd 30 job narendra.murlidhar 365
164 Connection with copper link with 50 Sq. mm Single Core flexible cable . Connection with copper link with 50 Sq. mm Single Core FRLS Copper PVC Insulated Flexible Cable for voltage grade upto 1100 V with copper lug on both end and length appx 0.5 mtr etc as reqd 30 job narendra.murlidhar 365
165 Providing and fixing 6 SWG dia G.I. wire on surface or in recess Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface or recessed conduit or submain wiring or cable as required. 80 metre narendra.murlidhar 365
166 Replacement of faulty LA Polymer or Porcelien type for overhead 11.0 KV Line Replacement of faulty LA Polymer or Porcelien type for overhead 11.0 KV Line of rated voltage 9.0 KV in rms and nominal discharge current rating 5 KA including Testing and Comm. etc complete as reqd 40 each narendra.murlidhar 365
167 Repalcement of faulty ACSR Conductor approx length 1mtr Repalcement of faulty ACSR Conductor approx length 1mtr with suitable Aluminium Lug etc complete as required 40 job narendra.murlidhar 365
168 Replacement of faulty 11 KV Pin Insulator Replacement of faulty 11 KV Pin Insulator Polymer or Porcelin etc complete as required 40 each narendra.murlidhar 365
169 Replacement of faulty 11 KV Disc insulator Replacement of faulty 11 KV Disc insulator Polymer or Porcelin etc complete as required 40 each narendra.murlidhar 365
170 Replacement of 11.0 KV Air break Gang Operated switch single pole Replacement of 11.0 KV Air break Gang Operated switch single pole with nuts bolts connectors etc iincluding testing commissioning etc complete as required. In case Individual phase failure 20 each narendra.murlidhar 365
171 Replacement of 11.0 KV Air break Gang Operated switch 3 pole Replacement of 11.0 KV Air break Gang Operated switch 3 pole with nuts bolts connectors etc including testing commissioning etc complete as required. In case of whole unit failure. 20 set narendra.murlidhar 365
172 Replacment of faulty or burnt out 11.0 KV DO fuse complete units of Three phase. Replacment of faulty or burnt out 11.0 KV DO fuse units for Three phase failure Includes various items like fuse bases fuse tubes arcing horns connectors and mounting hardware. etc as required 10 set narendra.murlidhar 365
173 Replacment of faulty or burnt out 11.0 KV DO fuse units for individual phase Replacment of faulty or burnt out 11.0 KV DO fuse units for single phase failure Includes various items like fuse bases fuse tubes arcing horns connectors and mounting hardware. etc as required 30 each narendra.murlidhar 365
174 Replacement of Silica gel crystal Replacement of Silica gel crystal typically blue in colour by removing old silica gel from existing breather including cleaning the breather filling with new etc complete as required 30 job narendra.murlidhar 365
175 Refilling of existing 4.5 Kg CO2 type fire extinguishers Refilling of existing 4.5Kg CO2 type fire extinguishers including transportation to and fro hydrualic pressure testing cleaning labling etc. complete as reqd. 80 each narendra.murlidhar 365
176 Replacement faulty R Y and G indication lamp Replacement faulty R Y and G indication lamp Pilot Light with Integral LED for 230 V AC 415 V AC of exsiting M.V. Panel Capacitor Panel Pump control Panel including Testing etc as reqd . 70 each narendra.murlidhar 365
177 Replacement faulty Blue indication lamp Replacement faulty Blue indication lamp Pilot Light with Integral LED for 230 V AC 415 V AC of exsiting M.V. Panel Capacitor Panel Pump control Panel including Testing etc as reqd . 70 each narendra.murlidhar 365
178 Replacement of faulty ON load Changeover or Switch disconector 63 A Replacement of faulty ON load Changeover or Switch disconector 63 A 415V AC 23A 4P Terminal Shrouds Source Separator and Phase Barriers suitable for horizontal and vertical mounting etc as reqd. 10 each narendra.murlidhar 365
179 Replacement of faulty ON load Changeover or Switch disconector 125 A Replacement of faulty ON load Changeover or Switch disconector 125 A 415V AC 23A 4P Terminal Shrouds Source Separator and Phase Barriers suitable for horizontal and vertical mounting etc as reqd. 10 each narendra.murlidhar 365
180 Replacement of faulty FN 63 TPN or FP Range 0 to 63 A SDF units Replacement of faulty FN 63 TPN or FP Range 0 to 63 A SDF units 415V AC 23A including removing or dismentling of existing faulty SDF testing commissioning etc complete as required 10 each narendra.murlidhar 365
181 Replacement of faulty FN 125 TPN Range 63A to 125A SDF units Replacement of faulty FN 125 TPN Range 63A to 125A SDF units 415V AC 23A including removing or dismentling of existing faulty SDF testing commissioning etc complete as required 10 each narendra.murlidhar 365
182 Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 2A to 32 A Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 2A to 32 A suitable for Type HF FN 32 FN 63 FNX 32 63 SDF and HCO 32 Fuse base etc complete as reqd 80 each narendra.murlidhar 365
183 Replacement Cylindrical HRC fuse links of rating 40 A Suitable for Type FN 63. FNX 63 SDF and HC 63 Fuse base Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 40 A Suitable for Type FN 63. FNX 63 SDF and HC 63 Fuse base etc complete as required 50 each narendra.murlidhar 365
184 Replacement Cylindrical HRC fuse links of rating 60 A Suitable for Type FN 63 FNX 63 SDF and for HC 63 Fuse base Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 60 A Suitable for Type FN 63 FNX 63 SDF and for HC 63 Fuse base etc complete as required 50 each narendra.murlidhar 365
185 Replacement of Cylindrical HRC fuse links of rating 63 A Suitable HN Suitable for Type FN 100 FN 125 FN160 FNX 100 FNX 125 FNX 160 SDF etc Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 63 A Suitable HN Suitable for Type FN 100 FN 125 FN160 FNX 100 FNX 125 FNX 160 SDF etc complete as required 50 each narendra.murlidhar 365
186 Replacement Cylindrical HRC fuse links of rating 100 A Suitable HN Suitable for Type FN 100 FN 125 FN160 FNX 100 FNX 125 FNX 160 SDF etc Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 100 A Suitable HN Suitable for Type FN 100 FN 125 FN160 FNX 100 FNX 125 FNX 160 SDF etc complete as required 50 each narendra.murlidhar 365
187 Replacement Cylindrical HRC fuse links of rating 125 A Suitable HN Suitable for Type FN 100 FN 125 FN160 FNX 100 FNX 125 FNX 160 SDF etc Replacement of Fused out or Faulty Cylindrical HRC fuse links of rating 125 A Suitable HN Suitable for Type FN 100 FN 125 FN160 FNX 100 FNX 125 FNX 160 SDF etc complete as required 50 each narendra.murlidhar 365

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Similar Tenders

4 found

NIT 78 ARC FOR CONST AND COMM OF 200 MM DIA. T UBE WELLS WITH SUBMERSIBLE PUMP SETS, CABLE A ND GI PIPE ETC. COMPLETE WORK IN ALL TYPES OF ST RATA INCLUDING PROVIDING, L AND J OF VARIOUS SI ZE OF PIPE LINE IN SUB DIV VIRATNAGAR, UNDER DIV ISION PAOTA

PHED-Chief Engineer(HQ),Jaipur

📍 JAIPUR, RAJASTHAN

EMD: ₹5.9 L
Est: ₹3.0 Cr
⏰ Deadline: 3 weeks left
🛒 Type: Works
View EPROCURE

NIT 79 ARC FOR CONST AND COMM OF 200 MM DIA. TUBE WELLS WITH SUBMERSIBLE PUMP SETS, CABLE AND GI PIPE ETC. COMPLETE WORK IN ALL TYPES OF STRATA INCLUDING PROVIDING, L AND J OF VARIOUS SIZE OF PIPE LINE IN SUB DIV KOTPUTLI, UNDER DIVISION PAOTA

PHED-Chief Engineer(HQ),Jaipur

📍 JAIPUR, RAJASTHAN

EMD: ₹5.9 L
Est: ₹3.0 Cr
⏰ Deadline: 3 weeks left
🛒 Type: Works
View EPROCURE

Tender for Cleaning of sewer line and Attending day to day Complaint related to Chockage and blockage of Sewer Line, Manholes, Gally trap, Flow Trap, WC Seat, Drainage system etc.

Dr. Ram Manohar Lohia Institute of Medical Sciences

📍 LUCKNOW, UTTAR PRADESH

EMD: ₹66,800
Est: ₹33.4 L
⏰ Deadline: 2 weeks left
🛒 Type: Service
View EPROCURE
Urgent

Providing 1.5 sqmm PVC insulated copper conductor cable for light fan call bell point including cost of backlit cover for MS box, switch, wall socket etc.

Haryana Government

📍 HISAR, HARYANA

EMD: ₹31,917
Est: ₹16.0 L
⏰ Deadline: 7 days left
🛒 Type: Works