TenderDekho Logo
Closed GEM

Tender Notice for Vibrometer - Induced Ground Vibration Monitoring Instrument in BOKARO, JHARKHAND

Bid Publish Date

16-Mar-2026, 11:53 am

Bid End Date

02-Apr-2026, 12:00 pm

EMD

₹11,000

Value

₹5,48,000

Generate Docs

Progress

Issue16-Mar-2026, 11:53 am
Technical04-Feb-2026, 11:53 am
Financial
AwardCompleted
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 5

A tender has been published for Central Coalfields Limited Vibrometer - Induced Ground Vibration Monitoring Instrument (Q3) in BOKARO, JHARKHAND. Quantity: 1 by. Submission Deadline: 02-04-2026 12: 00: 00. Check eligibility and apply.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Vibrometer - Induced Ground Vibration Monitoring Instrument (Q3)

Authority Records

MINISTRY OF COALCOAL INDIA LIMITED

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9113489.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Certification Compliance to Standard for Microphone ISEE 2011, IEC 61672 Class 1, ISEE2017
Certification Compliance to Standard for Geophone ISEE
Certification Warranty 1, 2, 3 Or higher
Construction Width of Data Monitoring & Control Unit(mm) 90-110
Construction Height of Data Monitoring & Control Unit(mm) 30-50
Construction Length of wire for geophone assembly(meter) 5-6
Construction Type of Geophone (Application based) Surface Fixed
Construction Length of Data Monitoring & Control Unit(mm) 130-150
Construction Length of wire for microphone assembly(meter) 2-3
Seismic Vibration Monitoring Resolution of Seismic Velocity(mm/sec) 0.006-0.009
Seismic Vibration Monitoring Minimum accuracy of Seismic velocity measurement 5%
Seismic Vibration Monitoring Minimum linear frequency response Geophone 2.0
Seismic Vibration Monitoring Maximum linear freqency response of Geophone 250.0
Sound Overpressure Monitoring Maximum Linear sound overpressure monitored (dB) 144-148
Sound Overpressure Monitoring Maximum Linear response of microphone 250.0
Sound Overpressure Monitoring Minimum linear frequency response microphone 2.0
Sound Overpressure Monitoring Minimum Linear sound overpressure monitored (dB) 82-88
Waveform recording & data collection Sample Rate per channel(samples/sec) 4096
Waveform recording & data collection Maximum Seismic trigger range(mm/sec) 250-255
Waveform recording & data collection Fixed Record time option available(Auto record off) Yes
Waveform recording & data collection Storage Capacity (Fullwave form events)at selected sample rate 3000-4000, 7500-10000
Waveform recording & data collection Waveform recording modes Fullwave form, Combined, Manual, NA
Waveform recording & data collection Maximum Linear sound trigger range(dB) 140-144
Waveform recording & data collection Minimum Linear sound trigger range(dB) 90-95
Waveform recording & data collection Minimum Seismic trigger range(mm/sec) 0.10-0.15
Histogram/Bar Graph Recording Bar code recording summary interval(Minutes) 5
Histogram/Bar Graph Recording Display facility feature available Peak particle velocity, Frequency, Displacement, Air over pressure level, Acceleration, Peak Vector Sum, RMS/Peak Velocity, Acceleration & Displacement
Histogram/Bar Graph Recording Bar recording interval options 1.0
Generic Parameters Water Proof(Submerged 20+ cm in water logged mines) Yes
Generic Parameters PC Interface USB
Generic Parameters Maximum operating temperature of device 50.0
Generic Parameters Handheld & portable data monitor Yes
Generic Parameters Thumb drive available for copying data field Yes
Generic Parameters Facility for manual entry of GPS Way points Yes
Generic Parameters Touch screen display available No, Yes
Generic Parameters Minimum operating temperature of device -20-(-)10
Generic Parameters Maximum Battery backup duration (Days) 8-10
Generic Parameters Modular Software for Vibration Data Analysis Provided Yes
Generic Parameters Facility of selection & deletion of false event Yes
Generic Parameters Facility for remote commuications Yes
Generic Parameters Number of function keys on Integrated keypad 10-12
Generic Parameters Integrated Keypad Yes, No
Accessories Carrying Case Yes
Accessories PC/Laptopn Connection Cable Yes
Accessories External data printer Yes, No

Required Documents

1

Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

2

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

26-Mar-2026

Extended Deadline

02-Apr-2026, 12:00 pm

Opening Date

02-Apr-2026, 12:30 pm

Technical Results

S.No Seller Item Date Status
1
SREE LAKSHMI GANESH ENTERPRISES   Under PMA
Make : Mini-Seis III Model : PRO02-04-2026 11:53:35
2
SVIB MEASUREMENT LABS LLP   Under PMA
Make : SVIB Model : SVIB1_CCL02-04-2026 11:30:55
3
YASH GROUP   Under PMA
Make : Mini-Seis III Model : PRO02-04-2026 10:30:30

Financial Results

Rank Seller Price Item
L1
SVIB MEASUREMENT LABS LLP   Under PMA
Item Categories : Vibrometer - Induced Ground Vibration Monitoring Instrument