Progress
Indian Council Of Medical Research (icmr) announces a tender for Biosafety Cabinet (V2) (Q2) in PUNE, MAHARASHTRA. Quantity: 43. Submission Deadline: 04-09-2026 21: 00: 00. Last date to apply is approaching fast!
Quantity
43
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
145
Past Performance
50 %
Warranty Period
3 years
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Biosafety Cabinet (V2) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
38
Pre-Bid Date
21-08-2026 15:00:00
Pre-Bid Venue
The meeting will be held virtually. The details of the meeting are as follows:- URL: https://bharatvc.nic.in/join/1777618817 Conference ID: 1777618817 Password: 905433 All representations/ queries from bidders must be submitted in advance through GeM portal. Additionally, the same may be sent via email to [email protected]/[email protected] on or before 18 August 2026 by 02:00 PM.
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Pune
Delivery Pincodes
411021
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Dawashree Dilip Marathe | 411021,ICMR-NIV, MCC 130/1 Sus Road, Pashan, Pune | Pune | Maharashtra | 411021 | 43 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
04-Sep-2026, 3:30 pm
Opening Date
04-Sep-2026, 4:00 pm
Extended Deadline
04-Sep-2026, 3:30 am
Opening Date
04-Sep-2026, 4:00 am
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Generic | Type of Cabinet | Class I, Class II, Class III |
| Generic | Sub Types of Class II | Type A1, Type A2, Type B1, Type B2, Type C1, NA |
| Generic | Vertical Laminar Flow | No, Yes |
| Dimensions & Construction | Installation Type | Bench-Mounted, Floor-Mounted |
| Dimensions & Construction | Outer Body Material | CRCA Antirust Treatment and Powder Coating, Precoated Sheet, SS 304 Stainless Steel, SS 316L Stainless Steel Or higher |
| Dimensions & Construction | Internal Body Material | CRCA Antirust Treatment and Powder Coating;, Precoated Sheet, SS 304 Stainless Steel, SS 316L Stainless Steel Or higher |
| Dimensions & Construction | Work Surface | Single-Piece SS 304 Stainless Steel, Segmented SS 304 Stainless Steel, Single-Piece SS 316L Stainless Steel, Segmented SS 316L Stainless Steel Or higher |
| Dimensions & Construction | Nominal Width Sizes in mm, Tolerance = ±50 mm | 600 mm, 900 mm, 1200 mm, 1500 mm, 1800 mm, 2400 mm |
| Dimensions & Construction | Height of Work Top from Ground Level in mm , Tolerance = ±50 mm | 750 mm, 900 mm |
| Dimensions & Construction | Front Window Material | Tempered Transparent UV Protected Glass, Transparent UV Protected Polycarbonate |
| Specification Performance | Inflow Velocity in (m/s) (Tolerance - ±0.03 m/s) | 0.38 m/s to 0.51 m/s, 0.38 m/s, 0.51 m/s, No Face Velocity |
| Specification Performance | Airflow | (100% room air in, 100% HEPA-filtered air out);, (70% recirculated; 30% exhausted), (~30% recirculated; ~70% exhausted), (Total Exhaust), Variable, Exhaust: Double HEPA filtered or HEPA + Incineration |
| Specification Performance | Ducting | Exhaust to room or via duct, Not required, Thimble connection optional, Hard-ducted to building exhaust system, Hard-ducted-Requires sophisticated pressure-independent exhaust monitors, Recirculating or Hard-ducted flexible, Double HEPA filtered or HEPA + Incineration |
| Specification Performance | Plenum | Negative Pressure plenums, Negative pressure to ensure vapors are exhausted, Positive Pressure Plenums, NA |
| Specification Performance | BSL Suitability | BSL-1, BSL-2, BSL-3, BSL-4 |
| Specification Performance | Cabinet Control System | Pressure Gauge for inflow and downflow, Motor Voltage Regulator, Audible and Visual Window Alarm, Main and Outlet Power Circuit Breakers, Power Switches for Exterior Mounted LED/Fluorescent Light and/or Ultraviolet Lights, Interior Outlets, Motor Controller, Filter Life Indicator, UV Lamp Timer, Automatic Airflow Compensation |
| Specification Performance | Number of Glove Port | 2, 4, NA |
| Specification Performance | Gloves Material | Neoprene (Poly-chloroprene - synthetic rubber), NA |