Public procurement opportunity for Indian Coast Guard Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E075 Sea water leakage observed from exhaust pipe line of Port DA between exhaust flap valve and hull penetration area Leakage needs to be arrested by weldin. . , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E076 AC condenser safety valve discharge pipeline to be routed outside of compartment Qty02 nos Pipeline length 03 mtr All inway jobs included Mat Copper dia. . , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E077 01 in no fire hydrant dia 55 mm locking pin deteriorated Locking pin to be repaired renewed as per sample; Service Provider, Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E078 Lub oil leakage observed from SME LO replenishment pump discharge pipeline near sump area Pipe dia 20 mm length 35 feet Mat MS Leakage needs to be arres. . in SOUTH ANDAMAN, ANDAMAN & NICOBAR. Quantity: 4 issued by. Submission Deadline: 23-10-2026 19: 00: 00. View full details and respond.
Quantity
4
Bid Type
Two Packet Bid
Bid Validity
120 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Tech Clarification Time
2 Days
EMD Required
No
MII Compliance
Yes
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
1
Experience Required
1 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Service
Bid To RA
No
Bid To RA Enabled
No
Item Category
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E075 Sea water leakage observed from exhaust pipe line of Port DA between exhaust flap valve and hull penetration area Leakage needs to be arrested by weldin.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E076 AC condenser safety valve discharge pipeline to be routed outside of compartment Qty02 nos Pipeline length 03 mtr All inway jobs included Mat Copper dia.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E077 01 in no fire hydrant dia 55 mm locking pin deteriorated Locking pin to be repaired renewed as per sample; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E078 Lub oil leakage observed from SME LO replenishment pump discharge pipeline near sump area Pipe dia 20 mm length 35 feet Mat MS Leakage needs to be arres..
Delivery Locations
1
Delivery Cities
South Andaman
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| - | South Andaman | South Andaman | - | - | Project / Lumpsum Based | - | Estimated Cost of Spare/Consumable s/Items on Reimbursement basis in Rs (please input 0 if not applicable) : 0 |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
OTHER
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer