TenderDekho Logo
GEM

Bids are Invited For Handheld Digital Infrared Thermometer in HYDERABAD, TELANGANA

Bid Publish Date

13-Feb-2026, 6:10 pm

Bid End Date

27-Feb-2026, 10:00 am

Progress

Issue13-Feb-2026, 6:10 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

20

Bid Type

Single Packet Bid

Categories 6

South Central Railway has released a public tender for Handheld Digital Infrared Thermometer (Q3) in HYDERABAD, TELANGANA. Quantity: 20. Submission Deadline: 27-02-2026 10: 00: 00. Download documents and apply online.

Documents 3

GeM-Bidding-8974677.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Handheld Digital Infrared Thermometer

East Central Railway

Posted: 19 December 2024
Closed: 30 December 2024
GEM

Handheld Digital Infrared Thermometer

South Central Railway

Posted: 13 June 2025
Closed: 23 June 2025
GEM

Handheld Digital Infrared Thermometer

Southern Railway

DAKSHINA KANNADA, KARNATAKA

Posted: 18 January 2025
Closed: 31 January 2025
GEM

Handheld Digital Infrared Thermometer

Southern Railway

Posted: 14 November 2024
Closed: 25 November 2024
GEM

Handheld Digital Infrared Thermometer

Northern Railway

Posted: 28 November 2024
Closed: 11 December 2024
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
PERFORMANCE (INFRARED / NON-CONTACT) Lowest Measurable Temperature (Infrared Non-contact) -70, -60, -50 Or lower
PERFORMANCE (INFRARED / NON-CONTACT) Highest Measurable Temperature (Infrared Non-contact) 800, 900, 950, 1000, 1050, 1100, 1200, 1300, 1370, 1400, 1470, 1500, 1600, 1700, 1800, 1850, 1900, 2000, 2100, 2200, 2300, 2400, 2500, 2600, 2700, 2800, 2900, 3000 Or higher
PERFORMANCE (INFRARED / NON-CONTACT) Display Resolution 0.1 Or lower
PERFORMANCE (INFRARED / NON-CONTACT) Basic Accuracy (±) 0.5, 0.75, 1 Or lower
PERFORMANCE (INFRARED / NON-CONTACT) Spectral Range (in micrometer) 8 TO 14
PERFORMANCE (INFRARED / NON-CONTACT) Optical Resolution-Far field (Distance to spot ratio) (calculated at 90% energy) 13:1, 20:1, 25:1, 30:1, 50:1, 60:1, 70:1, 75:1, 100:1, 150:1, 200:1, 250:1 Or higher
PERFORMANCE (INFRARED / NON-CONTACT) Emissivity (W/m2) Fixed at 0.95
DISPLAY / DATA OUTPUT Type of Display LCD
DISPLAY / DATA OUTPUT Back-light display Yes
DISPLAY / DATA OUTPUT Display Size(in inch) 2.0 to 2.4, 2.5 to 2.9, 3.0 to 3.4, 3.5 to 3.9, 4.0 to 4.4, 4.5 to 4.9, 5.0 to 5.4, 5.5 to 5.9, 6.0 to 6.4, 6.5 to 6.9 Or higher
DISPLAY / DATA OUTPUT Data Output to other devices Yes
DISPLAY / DATA OUTPUT Connectivity / interface NA
DISPLAY / DATA OUTPUT Data point logging capability (on board memory) 12, 20, 30, 40, 50, 100, 200, 500, 1000, 2000, 3000, 4000, 4999 Or higher
BATTERY Power Source Alkaline Batteries (Non-Rechargeable)
BATTERY Battery Size, if Non Rechargeable Battery AA
BATTERY Battery Chemistry Alkaline
BATTERY Battery Chargers for Rechargeable Batteries - inclusive in the scope of supply Yes
BATTERY Number of Batteries required for operation 1
BATTERY Number of Batteries supplied (Inclusive in the Scope of Supply) 0
BATTERY Battery back-up time under continuous use 12, 16, 20, 24, 30, 36, 48 Or higher
SALIENT FEATURES / FUNCTIONS Salient Features / Functions Datahold, Built-In Laser Sighting, Fahrenheit and Celsius Conversion, High and Low audible alarm, Low Battery indication, Maximum and Minimum Reading, Average and Differential reading
ACCESSORIES Standard accessories inclusive in the scope of supply Instruction booklet
GENERIC Built-in laser for precisely aiming the target Yes
GENERIC Laser Class Class II
GENERIC Laser sighting Single-point laser
GENERIC Optional/User Guide/Manual No
OPERATING CONDITIONS / INGRESS PROTECTION Minimum Operating Temperature -10, -15, -20, -25, -30 Or lower
OPERATING CONDITIONS / INGRESS PROTECTION Maximum Operating Temperature 50, 55, 60, 65, 70 Or higher
OPERATING CONDITIONS / INGRESS PROTECTION Maximum Operating Humidity at 40 deg C - Non-condensing (Rh) 90, 95 Or higher
OPERATING CONDITIONS / INGRESS PROTECTION Maximum Operating Altitude (meters above MSL) 501 to 2000, 2001 to 3000 Or higher
OPERATING CONDITIONS / INGRESS PROTECTION Ingress Protection IP 54, IP 65, IP 66, IP 67 Or higher
WARRANTY Warranty 1.0
CERTIFICATION / TEST REPORTS Compliance to Standards EN 61326-1, EN 61326-2 Electromagnetic Compatibility
CERTIFICATION / TEST REPORTS Hazardous location (Intrinsically Safe / non-incendive) approval Yes
CERTIFICATION / TEST REPORTS Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification Yes
CALIBRATION Calibration Certificate issuing authority NABL / ILAC accredited agency

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Past Performance

2

Certificate (Requested in ATC)

3

OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria

4

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer