XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1)
South Western Railway
Bid Publish Date
05-Jun-2026, 4:39 pm
Bid End Date
15-Jun-2026, 5:00 pm
EMD
₹1,50,000
Location
Progress
Quantity
1099
Category
XLPE Cable for Working Voltage up to and Including 1.1 KV Marked To IS 7098 (Part 1)
Bid Type
Two Packet Bid
Public procurement opportunity for Indian Army XLPE Cable for Working Voltage up to and Including 1. 1 KV Marked To IS 7098 (Part 1) (Q2), SITC DG 100kva, Earthing for 30KVA DG Set, Excavation for 30KVA DG Set, Returning for 30KVA DG Set, Removal of Excavated material for 30KVA DG Set, dwc pipe for 30KVA DG Set, SITC DG 30Kva, Earthing for 30KVA DG, Enclosure for 30KVA DG Set, Excavation for 30KVA DG set, Removing excavated material for 30KVA DG Set, DWC Pipe for 30KVA DG Set in DARJEELING, WEST BENGAL. Quantity: 1099 issued by. Submission Deadline: 15-06-2026 17: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
XLPE Cable for Working Voltage up to and Including 1.1 KV Marked To IS 7098 (Part 1) (Q2) , SITC DG 100kva , Earthing for 30KVA DG Set , Excavation for 30KVA DG Set , Returning for 30KVA DG Set , Removal of Excavated material for 30KVA DG Set , dwc pipe for 30KVA DG Set , SITC DG 30Kva , Earthing for 30KVA DG , Enclosure for 30KVA DG Set , Excavation for 30KVA DG set , Removing excavated material for 30KVA DG Set , DWC Pipe for 30KVA DG Set
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
South Western Railway
Rail Coach Factory Kapurthala
KAPURTHALA, PUNJAB
Southern Railway
CHENNAI, TAMIL NADU
North Central Railway
South Eastern Railway
Tender Results
Loading results...
SITC DG 100kva
Supply install commissioning and testing totally enclosed silent operation with canopy CPCB IV complaint static type diesel engine driven liquid cooled generating set of 100 KVA 80 KW capacity accommodated with acoustic encloser including suitable capacity of AMF panel at 0.8 lagging P.F 415V 50Hz 3 phase system for 0.85 load factor base plinth as per manufacturer recommendation A Disel Engine Diesel engine shall be 4 stroke liquid cooled electric start of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 degree Celsius 50 RH 1000m above MSL. electronic governor conforms to BS 5514 ISO 3046 BS 649 IS 10000 with capacity of 10 overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by Gol. Copy of the same shall be produced All other SPECIFICATIONS AS PER SCOPE OF WORK ATTACHED
Earthing for 30KVA DG Set
M L for pipe earthing complete with galvanised steel pipe electrode 40mm bore medium grade 2.5 metres length buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron strip of size 32x6 mm connected to galvanized earth pipe by means of bolts nuts checkouts and washers of galvanised iron including PCC 1 2 4 type B 1 precast RCC cover slab with suitable handle made of 6mm round bar including necessary excavation and earth work in any type of soil 20mm dia medium grade galvanised steel tube for watering with one and fix with cast iron funnel and wire mesh with protection pipe of 32mm dia light grade galvanised steel tubing up to 7.5 meters length for drawing earth lead with filling of bentonite in 600mm dia all around electrode etc complete including testing on completion and including taking down old U S earthing testing complete all as specified and as directed.
Excavation for 30KVA DG Set
Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation laying GI pipes and UG cables etc n exc 10 sqmtr Cum on plan in soft loose soil and getting out complete all as specified and directed.
Returning for 30KVA DG Set
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removal of Excavated material for 30KVA DG Set
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
dwc pipe for 30KVA DG Set
S L 75 mm outside dia double corrugated pipe DWDC ISI marked for enclosing cable below ground road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed
SITC DG 30Kva
Supply install commissioning and testing totally enclosed silent operation with canopy CPCB IV complaint static type diesel engine driven liquid cooled generating set of 30 KVA 24KW capacity accommodated with acoustic enclosure at 0.8 lagging P.F 415V 50Hz 3 phase system for 0.85 load factor base plinth as per manufacturer recommendation A Diesel Engine Diesel engine shall be 4 stroke liquid cooled electric start of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 degree celcius 50 RH 1000m above MSL electronic governor conforms to BS 5514 ISO 3046 BS 649 IS 10000 with capacity of 10 overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB A . The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GOI. Copy of the same shall be produced. All other SPECIFICATIONS AS PER SCOPE OF WORK ATTACHED
Earthing for 30KVA DG
M L for pipe earthing complete with galvanised steel pipe electrode 40mm bore medium grade 2.5 metres length buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron strip of size 32x6 mm connected to earthing plate with brass bolts nuts checknuts and washers of galvanised iron including PCC 1 2 4 type B 1 precast RCC cover 30cm x 30cm x 6cm with suitable main hole and frame etc. including necessary excavation and earth work in any type of soil 20mm dia medium grade galvanised steel tube for watering with channel funnel etc. and wire mesh and charcoal 50 with 50 common salt filling around pipe 32mm dia pipe galvanised steel bend up to 7.5 meters length for drawing earth electrode filled with bentonite in 600mm dia all around electrode complete including testing on completion and including taking down old u s earthing testing complete all as specified and directed.
Enclosure for 30KVA DG Set
Supply installing testing and commissioning indoor type stainless steel SS 316 cubical enclosure as per attached scope of work
Excavation for 30KVA DG set
Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation laying Gl pipes and UG cables etc n exc 10 sqmtr on plan in soft loose soil and getting out complete all as specified and directed.
Returning for 30KVA DG Set
Returning filing in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material for 30KVA DG Set
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
DWC Pipe for 30KVA DG Set
S L 75 mm outside dia double corrugated pipe DWC ISI marked for enclosing cable below ground road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | SITC DG 100kva | Supply install commissioning and testing totally enclosed silent operation with canopy CPCB IV complaint static type diesel engine driven liquid cooled generating set of 100 KVA 80 KW capacity accommodated with acoustic encloser including suitable capacity of AMF panel at 0.8 lagging P.F 415V 50Hz 3 phase system for 0.85 load factor base plinth as per manufacturer recommendation A Disel Engine Diesel engine shall be 4 stroke liquid cooled electric start of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 degree Celsius 50 RH 1000m above MSL. electronic governor conforms to BS 5514 ISO 3046 BS 649 IS 10000 with capacity of 10 overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by Gol. Copy of the same shall be produced All other SPECIFICATIONS AS PER SCOPE OF WORK ATTACHED | 1 | each job | ageem@sevoke | 60 | |
| 2 | Earthing for 30KVA DG Set | M L for pipe earthing complete with galvanised steel pipe electrode 40mm bore medium grade 2.5 metres length buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron strip of size 32x6 mm connected to galvanized earth pipe by means of bolts nuts checkouts and washers of galvanised iron including PCC 1 2 4 type B 1 precast RCC cover slab with suitable handle made of 6mm round bar including necessary excavation and earth work in any type of soil 20mm dia medium grade galvanised steel tube for watering with one and fix with cast iron funnel and wire mesh with protection pipe of 32mm dia light grade galvanised steel tubing up to 7.5 meters length for drawing earth lead with filling of bentonite in 600mm dia all around electrode etc complete including testing on completion and including taking down old U S earthing testing complete all as specified and as directed. | 4 | each job | ageem@sevoke | 60 | |
| 3 | Excavation for 30KVA DG Set | Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation laying GI pipes and UG cables etc n exc 10 sqmtr Cum on plan in soft loose soil and getting out complete all as specified and directed. | 62 | cum | ageem@sevoke | 60 | |
| 4 | Returning for 30KVA DG Set | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed | 56 | cum | ageem@sevoke | 60 | |
| 5 | Removal of Excavated material for 30KVA DG Set | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. | 6 | cum | ageem@sevoke | 60 | |
| 6 | dwc pipe for 30KVA DG Set | S L 75 mm outside dia double corrugated pipe DWDC ISI marked for enclosing cable below ground road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed | 260 | rm | ageem@sevoke | 60 | |
| 7 | SITC DG 30Kva | Supply install commissioning and testing totally enclosed silent operation with canopy CPCB IV complaint static type diesel engine driven liquid cooled generating set of 30 KVA 24KW capacity accommodated with acoustic enclosure at 0.8 lagging P.F 415V 50Hz 3 phase system for 0.85 load factor base plinth as per manufacturer recommendation A Diesel Engine Diesel engine shall be 4 stroke liquid cooled electric start of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 degree celcius 50 RH 1000m above MSL electronic governor conforms to BS 5514 ISO 3046 BS 649 IS 10000 with capacity of 10 overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB A . The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GOI. Copy of the same shall be produced. All other SPECIFICATIONS AS PER SCOPE OF WORK ATTACHED | 2 | each job | ageem@sevoke | 60 | |
| 8 | Earthing for 30KVA DG | M L for pipe earthing complete with galvanised steel pipe electrode 40mm bore medium grade 2.5 metres length buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead galvanised iron strip of size 32x6 mm connected to earthing plate with brass bolts nuts checknuts and washers of galvanised iron including PCC 1 2 4 type B 1 precast RCC cover 30cm x 30cm x 6cm with suitable main hole and frame etc. including necessary excavation and earth work in any type of soil 20mm dia medium grade galvanised steel tube for watering with channel funnel etc. and wire mesh and charcoal 50 with 50 common salt filling around pipe 32mm dia pipe galvanised steel bend up to 7.5 meters length for drawing earth electrode filled with bentonite in 600mm dia all around electrode complete including testing on completion and including taking down old u s earthing testing complete all as specified and directed. | 12 | each job | ageem@sevoke | 60 | |
| 9 | Enclosure for 30KVA DG Set | Supply installing testing and commissioning indoor type stainless steel SS 316 cubical enclosure as per attached scope of work | 2 | each | ageem@sevoke | 60 | |
| 10 | Excavation for 30KVA DG set | Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation laying Gl pipes and UG cables etc n exc 10 sqmtr on plan in soft loose soil and getting out complete all as specified and directed. | 37 | cum | ageem@sevoke | 60 | |
| 11 | Returning for 30KVA DG Set | Returning filing in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 33 | cum | ageem@sevoke | 60 | |
| 12 | Removing excavated material for 30KVA DG Set | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. | 4 | cum | ageem@sevoke | 60 | |
| 13 | DWC Pipe for 30KVA DG Set | S L 75 mm outside dia double corrugated pipe DWC ISI marked for enclosing cable below ground road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. | 150 | rm | ageem@sevoke | 60 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
North Western Railway
Modern Coach Factory Raebareli
Eastern Railway
📍 MALDA, WEST BENGAL
East Central Railway
📍 PATNA, BIHAR
East Central Railway
📍 PATNA, BIHAR
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS