Public Works Department Madhya Pradesh External Electrification Work Tender Rewa MP 2025 TS 1103 Dated 07-11-25
N/a
REWA, MADHYA PRADESH
Progress
Quantity
3098
Category
Operation and Maintenance of all Electrical Mechanical installations Internal External EI
Bid Type
Single Packet Bid
Airports Authority Of India, rhq Nr - Rangpuri invites bids for Operation and Maintenance of all Electrical Mechanical installations Internal External EI, Operation and Maintenance of all Electrical Mechanical installations, Inspection Servicing and testing of 11 KV HT Panels, Inspection Servicing and testing of 11 KV HT Panels For 2nd Year, Inspection Servicing Testing of 11 KV 433 V, Inspection Servicing Testing of 11 KV 433 Volts 2nd year, Inspection Servicing and testing of 1000Amp 415 volts, Inspection Servicing and testing of 1000Amp 415 volts 2nd year, Maintence Inspection Servicing and Testing of 150KVA Capacitor, Maintence Inspection Servicing and Testing of 150KVA Capacitor 2nd year, Servicing of Ashok Leyland make 10KVA DG Set, Servicing of Ashok Leyland make 10KVA DG Set 2nd year, Government Stamping Calibration, Reparing Rewinding and overhaulling of following submersible motor pump, Rewinding of ceiling fan wall mounted fan Exhaust fan, Lifting and lowering of 1520 HP submersible motor pump, Supply of ISI mark 3 Pin Plug Top 6 A, Supply of ISI mark 3 Pin Plug Top 16 A, Supply of 6 0 sqmm GLF cable, Supply of LED driver Circuit suitable, Supply of National Flag of 160 GSM size, Supply of ballast suitable for 400W lamp, Supply of 400W HPSV lamps, Supply of 1000W Halogen lamp, Supply of lgnitors for suitable HPSV Lamps, Supply of lgnitors suitable for MH lamps, Over hauling of existing 20 HP capcity, Over hauling of existing 75 HP capcity, Rewinding of Motor from 20 HP to 75 HP, Repairing of following pumps, Repairing of following pump, Performing B check on Kirloskar make, Replacement of following spares, Refilling of Existing Fire extinguishers, Reprogramming of Edwards make, Finishing with Epoxy paint two, Lettering with Black Japan paint, Finishing with Epoxy paint two or more coats, Percentage above or below on the rates of Electrical DSR 2022 in AMRITSAR, PUNJAB. Quantity: 3098. Submission Deadline: 27-02-2026 16: 00: 00. Submit your proposal before the deadline.
Main Document
BOQ
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
REWA, MADHYA PRADESH
N/a
REWA, MADHYA PRADESH
N/a
REWA, MADHYA PRADESH
N/a
REWA, MADHYA PRADESH
N/a
REWA, MADHYA PRADESH
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Operation and Maintenance of all Electrical Mechanical installations Internal External EI | Operation and Maintenance of all Electrical Mechanical installations Internal External EI such as Light fixtures fans light power points HT LT panels Transformers DG sets street lightning Synchronising panel of DG sets Capacitor Bank Panel Essential Non essential Panel Baggage coveyor system GLF system ic CCR Apron taxiway edge lights National Flag high mast High Masts street lighting Water Pumps STP WTP Fire alarm Fire hydrant systems and other associated installations by carrying out operation minor repair routine maintenance attending to complaints faults breakdowns and taking rectification action ensuring serviceability satisfactory working condition of the systems installed in the Airport Premises ic preventive maintenance maintenance of records documentation etc by deploying qualified manpower in three shifts General shift on all working days including Sunday Holidays as per special conditions of contract Deploying following minimum manpower on each day as required Highly Skilled 01nos Skilled 02 nos Semi skilled 03 nos Unskilled 01 nos Semi Skilled Reliver 01nos Note Bidder is restricted for quoting rate less than the Minimum monthly rate ie Rs 182946 with GST Falling which bid will be rejected and tender will be cancelled | 24 | month | [email protected] | 730 |
| 2 | Operation and Maintenance of all Electrical Mechanical installations | Operation and Maintenance of all Electrical Mechanical installations Internal External in addition to Item no 1 as and when required Skilled 01nos Note Bidder is restricted for quoting rate less than the Minimum rate ie Rs 961 with GST Falling which bid will be rejected and tender will be cancelled | 316 | days | [email protected] | 730 |
| 3 | Operation and Maintenance of all Electrical Mechanical installations | Operation and Maintenance of all Electrical Mechanical installations Internal External in addition to Item no 1 as and when required Un Skilled 01nos Note Bidder is restricted for quoting rate less than the Minimum rate ie Rs 690 with GST Falling which bid will be rejected and tender will be cancelled | 316 | days | [email protected] | 730 |
| 4 | Inspection Servicing and testing of 11 KV HT Panels | Inspection Servicing and testing of 11 KV HT Panels including Overhauling Servicing of 03 Nos 630 Amp VCBs Make ALSTOM maintenance of complete HT panel including checking all operational mechanisms functions positions tripping actions calibration of protective IDMT relays Model CDG Make ALSTOM one set contains 2 OC EF relay and checking their proper operation by secondary current injection technique and submitting the test reports accordingly etc complete as required For 1st Year | 1 | job | [email protected] | 730 |
| 5 | Inspection Servicing and testing of 11 KV HT Panels For 2nd Year | Inspection Servicing and testing of 11 KV HT Panels including Overhauling Servicing of 03 Nos 630 Amp VCBs Make ALSTOM maintenance of complete HT panel including checking all operational mechanisms functions positions tripping actions calibration of protective IDMT relays Model CDG Make ALSTOM one set contains 2 OC EF relay and checking their proper operation by secondary current injection technique and submitting the test reports accordingly etc complete as required For 2nd Year | 1 | job | [email protected] | 730 |
| 6 | Inspection Servicing Testing of 11 KV 433 V | Inspection Servicing Testing of 11 KV 433 Volts 400 KVA Oil Transformers including checking tightening of HT LT cable termination for 1st year | 2 | job | [email protected] | 730 |
| 7 | Inspection Servicing Testing of 11 KV 433 Volts 2nd year | Inspection Servicing Testing of 11 KV 433 Volts 400 KVA Oil Transformers including checking tightening of HTLT cable termination operation of tap changer testing of transformer oil ic acidity test insulation resistance of transformer for 2nd year | 2 | job | [email protected] | 730 |
| 8 | Inspection Servicing and testing of 1000Amp 415 volts | Inspection Servicing and testing of 1000Amp 415 volts LT Air circuit breaker including carrying out the following test and preventive maintenance along with submission of test reports General Inspection Wiring checking ic control and indicaitons R test between poles to earth between male and female contacts Continuity of power contacts Continuity of auxilary contacts Resistance measurement of tripping coil Closing tripping and interlocking testing Tripping through relay operation Secondary injection test of Inbuilt thermal and magnatic release and calibration of the same for 1st year | 3 | job | [email protected] | 730 |
| 9 | Inspection Servicing and testing of 1000Amp 415 volts 2nd year | Inspection Servicing and testing of 1000Amp 415 volts LT Air circuit breaker including carrying out the following test and preventive maintenance along with submission of test reports General Inspection Wiring checking ic control and indicaitons R test between poles to earth between male and female contacts Continuity of power contacts Continuity of auxilary contacts Resistance measurement of tripping coil Closing tripping and interlocking testing Tripping through relay operation Secondary injection test of Inbuilt thermal and magnatic release and calibration of the same for 2nd year | 3 | job | [email protected] | 730 |
| 10 | Maintence Inspection Servicing and Testing of 150KVA Capacitor | Maintence Inspection Servicing and Testing of 150KVA Capacitor Bank and taking rectification action preventive maintenance etc as required for 1st year | 2 | job | [email protected] | 730 |
| 11 | Maintence Inspection Servicing and Testing of 150KVA Capacitor 2nd year | Maintence Inspection Servicing and Testing of 150KVA Capacitor Bank and taking rectification action preventive maintenance etc as required For 2nd year | 2 | job | [email protected] | 730 |
| 12 | Servicing of Ashok Leyland make 10KVA DG Set | Servicing of Ashok Leyland make 10KVA DG Set model no LP10 Engine sr no B3201231 Alternator sr no 03131292 with Radiator cleaning the replacement of Diesal filter oil filter mobile oil etc complete as required including Bcheck for 1st year | 2 | job | [email protected] | 730 |
| 13 | Servicing of Ashok Leyland make 10KVA DG Set 2nd year | Servicing of Ashok Leyland make 10KVA DG Set model no LP10 Engine sr no B3201231 Alternator sr no 03131292 with Radiator cleaning the replacement of Diesal filter oil filter mobile oil etc complete as required including Bcheck For 2nd year | 2 | job | [email protected] | 730 |
| 14 | Government Stamping Calibration | Government Stamping Calibration and Re verification of Electronic weighing scales as per Govt Norms | 4 | job | [email protected] | 730 |
| 15 | Reparing Rewinding and overhaulling of following submersible motor pump | Reparing Rewinding and overhaulling of following submersible motor pump Set Submersible Monoblock motor pump set with suitable gauge copper wire ic warnishing baking with F class insulation ic dismantling transporation reinstallation testing and commissioning ic replacement of impellers all defective parts burnt out parts etc complete as required Credit towards dismantled copper wire damaged parts which shall be replaced may be considered the property of contractor accordingly rate shall be quoted 7 5KW 10HP water supply monoblock motor pump set | 2 | job | [email protected] | 730 |
| 16 | Reparing Rewinding and overhaulling of following submersible motor pump | Reparing Rewinding and overhaulling of following submersible motor pump Set Submersible Monoblock motor pump set with suitable gauge copper wire ic warnishing baking with F class insulation ic dismantling transporation reinstallation testing and commissioning ic replacement of impellers all defective parts burnt out parts etc complete as required Credit towards dismantled copper wire damaged parts which shall be replaced may be considered the property of contractor accordingly rate shall be quoted 0 75 1 HP drain monoblock motor pump set | 2 | job | [email protected] | 730 |
| 17 | Reparing Rewinding and overhaulling of following submersible motor pump | Reparing Rewinding and overhaulling of following submersible motor pump Set with suitable gauge copper wire ic warnishing baking with F class insulation ic replacement of impellers all defective parts burnt out parts etc complete as required Credit towards dismantled copper wire damaged parts which shall be replaced may be considered the property of contractor accordingly rate shall be quoted 20 HP 15HP submersible motor pump set | 2 | job | [email protected] | 730 |
| 18 | Rewinding of ceiling fan wall mounted fan Exhaust fan | Rewinding of ceiling fan wall mounted fan Exhaust fan Dessert Cooler of different size including replacement of bearings bushing servicing repairing and transportation from site to contractors workshop back to site testing and commissioning etc complete as required Credit towards dismantled copper wire damaged parts which shall be replaced may be considered the property of contractor accordingly rate shall be quoted | 20 | job | [email protected] | 730 |
| 19 | Lifting and lowering of 1520 HP submersible motor pump | Lifting and lowering of 1520 HP submersible motor pump set ic dismentling checking reinstallation after repeir jointing of cable testing and commissioning etc complete as required | 2 | job | [email protected] | 730 |
| 20 | Supply of ISI mark 3 Pin Plug Top 6 A | Supply of ISI mark 3 Pin Plug Top 6 A suitable for operation on 230 Volt AC supply complete as required | 10 | nos | [email protected] | 730 |
| 21 | Supply of ISI mark 3 Pin Plug Top 16 A | Supply of ISI mark 3 Pin Plug Top 16 A suitable for operation on 230 Volt AC supply complete as required | 10 | nos | [email protected] | 730 |
| 22 | Supply of 6 0 sqmm GLF cable | Supply of 6 0 sqmm GLF cable ESNA Connection kit as per preferred make list | 10 | each | [email protected] | 730 |
| 23 | Supply of LED driver Circuit suitable | Supply of LED driver Circuit suitable for LED type Taxi edge light as per preferred make list | 10 | each | [email protected] | 730 |
| 24 | Supply of National Flag of 160 GSM size | Supply of National Flag of 160 GSM size of 30 Ft X 20Ft in 100 percentage knitted polyester with reinforced super strong nylon webbing on all 3 sides rope toggle sleeve as and when required | 4 | nos | [email protected] | 730 |
| 25 | Supply of ballast suitable for 400W lamp | Supply of ballast suitable for 400W lamp HPSV light Fixture as per preferred make list | 20 | each | [email protected] | 730 |
| 26 | Supply of 400W HPSV lamps | Supply of 400W HPSV lamps as per preferred make list | 20 | each | [email protected] | 730 |
| 27 | Supply of 1000W Halogen lamp | Supply of 1000W Halogen lamp as per aproved make list | 20 | each | [email protected] | 730 |
| 28 | Supply of lgnitors for suitable HPSV Lamps | Supply of lgnitors for suitable HPSV Lamps as per preferred make list | 20 | each | [email protected] | 730 |
| 29 | Supply of lgnitors suitable for MH lamps | Supply of lgnitors suitable for MH lamps as per preferred make list | 20 | each | [email protected] | 730 |
| 30 | Over hauling of existing 20 HP capcity | Over hauling of existing 20 HP capcity jockey fire pump and motor suitable to operate on 415v 50Hz 3 phase AC etc as required | 2 | job | [email protected] | 730 |
| 31 | Over hauling of existing 75 HP capcity | Over hauling of existing 75 HP capcity main fire pump and motor suitable to operate on 415v 50Hz 3 phase AC etc as required | 2 | job | [email protected] | 730 |
| 32 | Rewinding of Motor from 20 HP to 75 HP | Rewinding of Motor from 20 HP to 75 HP capcity fire pumps suitable to operate on 415v 50Hz 3 phase AC supply with suitable gauge copper wire ic varnishing baking etc as required Burnt wire belongs to contractor | 1 | job | [email protected] | 730 |
| 33 | Repairing of following pumps | Repairing of following pumps including replacement of Bearings shaft shaft sleeves gland plate gland by deputing skilled Manpower Machineries etc required at site as per site requirement Jockey pump 20 HP | 1 | job | [email protected] | 730 |
| 34 | Repairing of following pump | Repairing of following pumps including replacement of Bearings shaft shaft sleeves gland plate gland by deputing skilled Manpower Machineries etc required at site as per site requirement Main Pump 75 HP | 1 | job | [email protected] | 730 |
| 35 | Repairing of following pumps | Repairing of following pumps including replacement of Bearings shaft shaft sleeves gland plate gland by deputing skilled Manpower Machineries etc required at site as per site requirement Diesel pump 92HP | 1 | job | [email protected] | 730 |
| 36 | Performing B check on Kirloskar make | Performing B check on Kirloskar make Fire DG set as per OEM recommendations including supply replacement of material viz filter oil etc all inclusive for doing B check | 2 | each | [email protected] | 730 |
| 37 | Replacement of following spares | Replacement of following spares as per approved make and compatible to existing system as per site requirement as and when required 12 V 180 AH battery with buyback offer and warranty of min 02 years | 2 | each | [email protected] | 730 |
| 38 | Replacement of following spares | Replacement of following spares as per approved make and compatible to existing system as per site requirement as and when required Mannual call Point | 5 | each | [email protected] | 730 |
| 39 | Replacement of following spares | Replacement of following spares as per approved make and compatible to existing system as per site requirement as and when required Hooter | 5 | each | [email protected] | 730 |
| 40 | Replacement of following spares | Replacement of following spares as per approved make and compatible to existing system as per site requirement as and when required Smoke Heat Detector | 20 | each | [email protected] | 730 |
| 41 | Replacement of following spares | Replacement of following spares as per approved make and compatible to existing system as per site requirement as and when required Hose pipe | 8 | each | [email protected] | 730 |
| 42 | Replacement of following spares | Replacement of following spares as per approved make and compatible to existing system as per site requirement as and when required Pressure Gauge | 4 | each | [email protected] | 730 |
| 43 | Refilling of Existing Fire extinguishers | Refilling of Existing Fire extinguishers ABC CO2 upto capacity of 6kgs as and when required | 30 | job | [email protected] | 730 |
| 44 | Reprogramming of Edwards make | Reprogramming of Edwards make EST 3 fire alarm control panel as and when required | 1 | each | [email protected] | 730 |
| 45 | Finishing with Epoxy paint two | Finishing with Epoxy paint two or more coats at all locations prepared and applied as per manufacturers specifications including appropriate priming coat preparation of surface etc complete on the steel work Colour of paint shall be decided by the EIC | 80 | sqm | [email protected] | 730 |
| 46 | Lettering with Black Japan paint | Lettering with Black Japan paint or other approved colour of approved brand and manufacturer | 2,000 | no cm | [email protected] | 730 |
| 47 | Finishing with Epoxy paint two or more coats | Finishing with Epoxy paint two or more coats of Street light pole 9 m High at all locations prepared and applied as per manufacturers specifications including appropriate priming coat preparation of surface etc complete on the steel work Colour of paint shall be decided by the EIC | 80 | no | [email protected] | 730 |
| 48 | Percentage above or below on the rates of Electrical DSR 2022 | Percentage above or below on the rates of Electrical DSR 2022 CPWD including GST items worth totaling to Rs 100000 as per requirement Note the firm has to quote upload the percentage above below plus minus percentage on the quantity mentioned against this item directly in the form of multiplying factor in the rate column as clarified below For if desired to quote 5 percentage above on DSR 2022 rates the rate column shall be filled as 1 05 If desired to quote 3 percentage below on DSR 2022 rates the rate column shall be filled as 0 97 | 1 | job | [email protected] | 730 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Gujarat Water Infrastructure Ltd
📍 GANDHINAGAR, GUJARAT
Gujarat Water Infrastructure Ltd
📍 GANDHINAGAR, GUJARAT
Gujarat Water Infrastructure Ltd
📍 GANDHINAGAR, GUJARAT
Indian Institute of Management Jammu
📍 JAMMU, JAMMU AND KASHMIR
Uttar Pradesh Power Corporation Limited (uppcl)
📍 SANT RAVIDAS NAGAR, UTTAR PRADESH
Sign up now to access all documents
Main Document
BOQ
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS