C Arm Fluoroscope X - Ray Machine (V2)
Electronics Corporation Of India Limited
Public procurement opportunity for N/a C Arm Fluoroscope X - Ray Machine (V2) (Q2) in ERNAKULAM, KERALA. Quantity: 1 issued by. Submission Deadline: 02-03-2026 13: 00: 00. View full details and respond.
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Electronics Corporation Of India Limited
U.p.rural Institute Of Medical Sciences And Research Saifai
ETAWAH, UTTAR PRADESH
Directorate Of Medical Education And Training
ALLAHABAD, UTTAR PRADESH
Directorate Of Medical Education And Training
ALLAHABAD, UTTAR PRADESH
N/a
TIRUCHIRAPPALLI, TAMIL NADU
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | C Arm Fluoroscope X-Ray Machine |
| PRODUCT INFORMATION | The System should be microprocessor controlled, compact and mobile offering excellent Image details | Yes |
| PRODUCT INFORMATION | Type of Mechanical Motion of C Arm | Motorized |
| PRODUCT INFORMATION | Horizontal movement of C Arm ( in mm) | 170 - 240 |
| PRODUCT INFORMATION | Vertical Movement of C Arm (in mm) | 400 - 450 |
| PRODUCT INFORMATION | Angulation Movement of C Arm (in degrees) | ± 200 |
| PRODUCT INFORMATION | Radius (Immersion Depth) of C arm in mm | 610 - 750 |
| PRODUCT INFORMATION | Source to Image Distance in mm | 1001 - 1050 |
| PRODUCT INFORMATION | Arc Orbital Movement of C Arm | Atleast +90°- 40° |
| PRODUCT INFORMATION | Total width of C Arm in mm ( Free space of C arm) | 600 - 850 |
| PRODUCT INFORMATION | Panning Movement of C Arm (Swivel movement) | ±12.5º |
| PRODUCT INFORMATION | Safety feature available for C Arm Movement | Locks for all the movements, Control Stand foot lock, Steering wheel for easy steering & movement |
| PRODUCT INFORMATION | Range of Frequency of X ray Generator in khz | More than 100 |
| PRODUCT INFORMATION | Generator Power output in Kw | 3.5 |
| PRODUCT INFORMATION | Fluoroscopy Range in kvp | 40 - 120 |
| PRODUCT INFORMATION | Fluoroscopy mA range, maximum in mA | 0.2 to 7 |
| PRODUCT INFORMATION | Dual focus Rotating Anode X-Ray Tube of focal spot or Stationary Anode X-Ray Tube of focal spot | 0.6mm² (small) & 1.5mm² (large) |
| PRODUCT INFORMATION | Anode heat storage capacity with tolerance ±10% | 500 KHU |
| PRODUCT INFORMATION | Modes Available | Continuous fluoro, Pulsed Fluoro, Radiographic Mode |
| PRODUCT INFORMATION | Pulses per sec | 1 to 30 |
| PRODUCT INFORMATION | Mode selection for Kv and mA | Automatic |
| PRODUCT INFORMATION | Type of Image Intensifier | 12 " Triple Field |
| PRODUCT INFORMATION | Number of Monitors provided on/with intensifier system | 2 (One for LIH and one for memory display ) |
| PRODUCT INFORMATION | Type of monitor to be provided with intensifier system | LCD / LED / TFT |
| PRODUCT INFORMATION | Size of Monitors in inch | 21 - 24 |
| PRODUCT INFORMATION | Type of Collimator controlled | Both Fixed Collimation Slot & Motorized IRIS |
| PRODUCT INFORMATION | Type of Camera | CMOS Camera |
| PRODUCT INFORMATION | Camera Resolution in pixels | 2K x 2K |
| PRODUCT INFORMATION | Acquisition of Camera | 14 bits |
| PRODUCT INFORMATION | Contrast ratio of intensifier unit | 10:1 to 30:1 |
| PRODUCT INFORMATION | Image storage capacity in images | Above 100000 |
| PRODUCT INFORMATION | Image reversal | Yes |
| PRODUCT INFORMATION | Zoom function available | 5x |
| PRODUCT INFORMATION | Monitor with trolley | Yes |
| PRODUCT INFORMATION | Sterile covers for C-Arm/X-Ray tube/ Image Intensifier | Yes |
| PRODUCT INFORMATION | DICOM Compatibility | Yes |
| PRODUCT INFORMATION | The system should be ready to connect with HIS/ PACS | Yes |
| PRODUCT INFORMATION | Data transfer | USB and CD/DVD |
| PRODUCT INFORMATION | Number of Lead Aprons - Full body and Skirt type | (0.5pb) 4 number each |
| PRODUCT INFORMATION | Number of Thyroid shield | 4 |
| PRODUCT INFORMATION | Number of Gonald Shield | 4 |
| PRODUCT INFORMATION | Radiation/Fuoro Exposure delivery Switch | Hand Switch and Foot Switch |
| PRODUCT INFORMATION | Display of mA, KV and other safety features on C - arm Console | Yes |
| PRODUCT INFORMATION | Radiography through Cassette with holder | Yes |
| PRODUCT INFORMATION | Size of Cassette holder provided (for radiographic mode) in inch x inch | 12 x 12 |
| PRODUCT INFORMATION | Patient demographic detail entry facility | Yes |
| PRODUCT INFORMATION | Upgradable option to digital substration of angigraphy and peripheral angiography | No |
| PRODUCT INFORMATION | Automatic image parameter selection with capability of switching on to manual selection | Yes |
| PRODUCT INFORMATION | Type of Power Supply | Single phase, 220- 240 Vac, 50Hz-16 Amps Socket |
| PRODUCT INFORMATION | UPS Availability | Built in |
| PRODUCT INFORMATION | UPS backup time in minutes | 15, 30, 45 Or higher |
| PRODUCT INFORMATION | Servo Stabilizer provided | Yes |
| PRODUCT INFORMATION | Rating of Servo Stabilizer | 5 KVA |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Conformity to safety standards | IEC 60601-2-54 or BIS equivalent |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | AERB Type Approved Equipment | Yes |
| CERTIFICATIONS | Conformity to Indian Standard IS 7620- Part 1, Part 2, Part 3 | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5.0 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS