Bid Publish Date
28-Aug-2026, 10:44 am
Bid End Date
09-Sep-2026, 11:00 am
Value
₹5,77,200
Location
Progress
Rail Wheel Factory Yelahanka invites bids for Electrocardiography (ECG) Machine (V2) (Q2) in BANGALORE, KARNATAKA. Quantity: 4. Submission Deadline: 09-09-2026 11: 00: 00. Submit your proposal before the deadline.
Quantity
4
Bid Type
Single Packet Bid
Bid Validity
60 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Past Performance
20 %
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Electrocardiography (ECG) Machine (V2) (Q2)
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Bengaluru Urban
Delivery Pincodes
560064
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Archana.S | 560064,OFFICE OF THE PCMO,RAILWAY HOSPITAL.,RAIL WHEEL FACTORY, YELAHANKA, BENGALURU - 560064 | Bengaluru Urban | Karnataka | 560064 | 4 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Past Performance
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product Description | ECG Machine |
| PRODUCT INFORMATION | Operating modes of ECG Machine | Automatic, Manual and Rhythm |
| PRODUCT INFORMATION | ECG machine should have ECG lead annotation facility | Yes |
| PRODUCT INFORMATION | Leads which is in ECG machine should be able to acquire simultaneously and interpret them | 12 |
| PRODUCT INFORMATION | Number of channels | 12 Channel |
| PRODUCT INFORMATION | ECG machine should acquire lead ECG for both adult and pediatric patients | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show lead fail indication | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show lead reversal indication | Yes |
| PRODUCT INFORMATION | The ECG machine should have facility to show the impedance to quality check of connection | Yes |
| PRODUCT INFORMATION | Acquisition time for ECG Machine in sec | 10 sec |
| PRODUCT INFORMATION | Digital sampling rate for Pacemaker spike detection | 8000 s/sec/channel, NA |
| PRODUCT INFORMATION | Recording of digital sampling for pacemaker | 1000 s/sec/channel |
| PRODUCT INFORMATION | ECG machine should have real time colour backlit display of ECG waveforms with signal qualify indication for each lead | Yes |
| PRODUCT INFORMATION | ECG machine should have frequency filters | Artifact, AC and low and high pass frequency filters |
| PRODUCT INFORMATION | Number of ECGs which can be store in ECG Machine | 151 to 200 |
| PRODUCT INFORMATION | ECG machine should have full screen preview of ECG report for quality assessment checks prior to print | Yes |
| PRODUCT INFORMATION | Type of inbuilt screen | LCD |
| PRODUCT INFORMATION | Size of screen in inches | 5 |
| PRODUCT INFORMATION | Display resolution of ECG machine in pixels | 640 x 480 |
| PRODUCT INFORMATION | ECG machine should have interpretation facility of the amplitudes, duration and morphologies of ECG waveforms and associated rhythm for adult and pediatric patient | Yes |
| PRODUCT INFORMATION | ECG machine should have alphanumeric keyboard for patient data entry | Hard keys |
| PRODUCT INFORMATION | Availability of latest interpretation software | Yes |
| PRODUCT INFORMATION | Wireless acquisition module with RF technology | No |
| PRODUCT INFORMATION | System should have the dedicated software to download the ECG form machine in PDF format | Yes |
| PRINTER | Printer Type | Thermal Printer |
| PRINTER | Recorder Paper Size | A4 Size |
| PRINTER | Recorder Speed | 50 mm/sec |
| PRINTER | Resolution of digital array printer | 200 dpi x 500 dpi |
| PRINTER | Number of Thermal paper | 500, 1000 Or higher |
| PRINTER | ECG machine report format | Report formats of 3x4, 6x2, Rhythm for up to selected leads, 12 lead extended measurement, 1 minute of continuous waveform data for 1 selected lead |
| BATTERY | Provision of Battery | Yes |
| BATTERY | Battery Type | Built in Rechargeable Battery |
| BATTERY | Battery capacity of continuous rhythm recording on single charge (minutes) | 60 |
| BATTERY | Battery capacity | 50 ECG or 1 hour of continous rhythm recording on single charge |
| BATTERY | Connectivity to ECG Machine | LAN |
| BATTERY | The individual patient lead should be change without replacing the whole patient cable assembly | Yes |
| ENVIRONNMENTS PARAMETERS | Operating temperature and humidity | Temperature of 10 to 40 degree Celsius and Relative Humidity of 15 to 90% |
| POWER SUPPLY | Power input | 220-240 V AC, 50 Hz fitted with Indian plug |
| ACCESSORIES | ECG Machine 12 leads with interpretation | 1 |
| ACCESSORIES | Patient Cable | 2 |
| ACCESSORIES | Chest Electrodes Adult (set of Six) | 1, Not provided |
| ACCESSORIES | Chest Electrodes Paediatric (set of Six) | Not provided |
| ACCESSORIES | Limb Electrodes | 2 for adults and 2 for paediatric, Not provided |
| ACCESSORIES | Power cable for charging | Yes |
| ACCESSORIES | Supplied with Clip electrode | Yes |
| ACCESSORIES | Compatible trolley provided | Yes |
| CERTIFICATION & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION & REPORTS | Availability of valid Medical Device license from competent authority | Yes |
| CERTIFICATION & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATION & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION & REPORTS | Compliance to Safety Standards | IS 13450:Part 2:Sec 25 / IEC 60601-2-25 |
| CERTIFICATION & REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| WARRANTY | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 4, 5 Or higher |
| Miscellaneous Parameters | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| Miscellaneous Parameters | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| Miscellaneous Parameters | Installation and demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |