TenderDekho Logo
Closed GEM

Procurement Opportunity: Bulk Milk Cooler Unit in TIRUVANNAMALAI, TAMIL NADU

Bid Publish Date

24-Feb-2026, 2:54 pm

Bid End Date

13-Mar-2026, 3:00 pm

Generate Docs

Progress

Issue24-Feb-2026, 2:54 pm
Corrigendum05-Mar-2026
AwardPending

Tamil Nadu Cooperative Milk Producers Federation L has released a public tender for Bulk Milk Cooler Unit (Q2) in TIRUVANNAMALAI, TAMIL NADU. Quantity: 2. Submission Deadline: 13-03-2026 15: 00: 00. Download documents and apply online.

Tender Data

Bid Details

Quantity

2

Bid Type

Two Packet Bid

Bid Validity

30 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

3 Days

Requirements

Min. Avg. Annual Turnover

21

Past Performance

50 %

Experience Required

2 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Bulk Milk Cooler Unit (Q2)

Authority Records

TAMILNADU DAIRY DEVELOPMENT CORPORATION LIMITED

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 3

GeM-Bidding-9037461.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Corrigendum Updates

3 Updates
#1

Update

05-Mar-2026
#2

Update

05-Mar-2026
#3

Update

03-Mar-2026

Extended Deadline

13-Mar-2026, 9:30 am

Opening Date

13-Mar-2026, 10:00 am

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria

6

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Bulk Milk Cooler Tank CIP Piping For Closed type tank facilities for cleaning in place shall be provided which include CIP spray balls & SS piping from balance tank through milk pump to BMC and back to balance tank
Bulk Milk Cooler Tank Number of Agitators 1
Bulk Milk Cooler Tank Thickness of Inner shell of tank 2.0
Bulk Milk Cooler Tank Certificaton As Per ISO 5708 Type 2A II (Latest Version) Stndard
Bulk Milk Cooler Tank Thickness of Outer shell of tank 1.6
Bulk Milk Cooler Tank Bulk Milk Cooler Tank Rated Capacity 5000, 10000 Or higher
Bulk Milk Cooler Tank Number of SS 304 Hooks for Hose Pipe 4
Bulk Milk Cooler Tank Tank Type Closed Type
Bulk Milk Cooler Tank CIP Facility CIP Cleaning by spray balls using pump and balance tank for closed type tanks
Bulk Milk Cooler Tank Milk Inlet System Pump Feed System
Bulk Milk Cooler Tank Bulk Milk Cooler Tank Gross Capacity 5500, 11000 Or higher
Bulk Milk Cooler Tank Auto CIP System for Bulk Milk Cooling Tank Pre-Programed Automatic CIP system for claening of Milk Cooling Tank
Bulk Milk Cooler Tank Top cover opening limit switch for open type tank NA
Milk Tank Control Panel Display Type LED
Main Contol Panel with Servo Voltage Stabilizer Phase Three Phase
Main Contol Panel with Servo Voltage Stabilizer Voltage range 300 to 500 V
Refrigeration Unit Type of Refrigerant R22 or CFC free refrigerant
Refrigeration Unit Number of Compressor 2
Milk Pump Head in mwc 10 MWC
Milk Pump Flow Rate 10000 LPH
Food grade tanker loading/unloading hose pipe Size 38.0
Water Handling System for Bulk Milk Cooler Capacity 0.5 HP, 10 mwc
Hot Water Generator - Heat Recovery Unit Quantity 1, 2 Or higher
Fire Extinguisher ABC stored pressure type fire extinguisher 1kg each 3
Diesel Generator (DG) Set DG Set Capacity, kVA 25
Diesel Generator (DG) Set No of Phase Three Phase
Diesel Generator (DG) Set Alternator IP Rating IP 23
Diesel Generator (DG) Set IP Rating of Control Panel IP 54
Data Logging System UPS 7AH Battery with 8 Hours Backup
Data Logging System GRID Sensor LDR based and isolated to protect the reverse current flow.
Data Logging System Volume Sensor Pressure Based, EHEDG compliant, Food Grade
Data Logging System Display 7 Segment LED
Data Logging System DG Sensor LDR based
Data Logging System Temperature Sensor 0-70 Degree Celciuos, Housing SS 304
Data Logging System Compressor Sensor Current transmitting sensors
Data Logging System Panel Board Metal Powder Coated/Height 50CM and Width 50 CM and Inner width 12.5 CM
Installation, commissioning, trial runs and putting the BMCU in operation Interconnecting piping for the entire plant SS 304 piping 38 mm diameter, 1.6 mm thick