Bid Publish Date
21-Aug-2026, 5:39 pm
Bid End Date
31-Aug-2026, 6:00 pm
EMD
₹30,000
Location
Progress
A tender has been published for Indian Council Of Medical Research (icmr) Gel Documentation System (Q2) in THANE, MAHARASHTRA. Quantity: 1 by. Submission Deadline: 31-08-2026 18: 00: 00. Check eligibility and apply.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
45
OEM Avg. Turnover
40
Past Performance
50 %
Warranty Period
7 days
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Gel Documentation System (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
62
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Palghar
Delivery Pincodes
401208
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Vikas Dnyaneshwar Dighe | 401208,Plot No. 80-1A, Sasunavghar (Maljipada), Taluka Vasai, District Thane, Pin code - 401208 | Palghar | Maharashtra | 401208 | 1 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Performance Parameters | Camera imager for imaging applications | DNA gels, Protein gels |
| Performance Parameters | Type of Camera | CMOS |
| Performance Parameters | System should enable detection of picogram levels of sample with chemiluminescence | Yes Or higher |
| Performance Parameters | Display | Touch screen |
| Performance Parameters | Machine should have onboard capture and analyse software for ease of use and automation, with PC connectivity and USB connection | Yes Or higher |
| Performance Parameters | Camera with fixed focus motorized lens | Yes Or higher |
| Performance Parameters | Cooling Temperature available for the camera in °C | NA (if Chemi is not available) |
| Performance Parameters | Camera resolution in Mega Pixel (MP) | >= 8 Mega Pixel |
| Performance Parameters | Compact dark room should include | UV Transilluminater |
| Performance Parameters | UV transillumination wavelength (nm) | 302 |
| Performance Parameters | Imaging area in cm x cm with tolerance of ±10% | 20 x 24 |
| Performance Parameters | Machine should include positions motorised filter wheel with suitable filter for EtBr, SYBR Green, Coomassie Blue, Silver Stain | 1 |
| Performance Parameters | Sample placement slot should be adjustable as per user requirement and application specific trays for UV, White and Chemiluminescent Blot samples should be provided | Yes, No Or higher |
| Performance Parameters | Modes of image capturing | Automatic |
| Performance Parameters | Analysis software | 1D |
| Miscellaneous Parameters | Comprehensive Warranty in years | 2 |
| Miscellaneous Parameters | Number of installations of the Machine machines in Central /State/PSU Govt Hospitals( Note: Seller should supply a performace certificate of the device to the buyer if demanded after placement of order) | No installations, Upto 3, More than 3 |