Progress
Quantity
475
Category
Supply installation testing and commissioning of Outdoor Inverter Printed Circuit Board for VRV outdoor unit including replacement wiring testing complete as per OEM specification
Bid Type
Two Packet Bid
A tender has been published for Indo Tibetan Border Police (itbp) Cleaning and servicing of 4 TR tower type air conditioner including cleaning of filters blower coils drain line electrical checks testing and commissioning complete as per OEM specifications, Providing and filling of compatible R22 or R32 refrigerant gas for 1 point 5 TR split air conditioner including leak testing and making unit functional complete, Nitrogen pressure testing of VRV air conditioning system for leak detection including nitrogen charging pressure holding joint leak testing complete as per OEM specifications, Providing and Filling of R 410A Gas in Main VRV Unit as per direction and upto satisfaction of Engr in charge, Supply installation testing and commissioning of Printed Circuit Board for VRV indoor unit including replacement wiring testing and making system functional complete as per OEM specifications, Supply installation testing and commissioning of Outdoor Inverter Printed Circuit Board for VRV outdoor unit including replacement wiring testing complete as per OEM specification, Dismantling damaged wiring and providing laying testing and commissioning of new 2 core 2 point 5 sqmm copper cable for VRV VRF system complete with termination and testing as per specifications, Repairing of Indoor Printed Circuit Board for VRV indoor unit including fault diagnosis component replacement servicing testing and making unit functional complete as per OEM specifications, Providing and replacement of indoor fan motor assembly for VRV indoor unit including dismantling installation wiring testing and making unit functional complete as per OEM specifications in PANCHKULA, HARYANA. Quantity: 475 by. Submission Deadline: 17-08-2026 12: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Cleaning and servicing of 4 TR tower type air conditioner including cleaning of filters blower coils drain line electrical checks testing and commissioning complete as per OEM specifications , Providing and filling of compatible R22 or R32 refrigerant gas for 1 point 5 TR split air conditioner including leak testing and making unit functional complete , Nitrogen pressure testing of VRV air conditioning system for leak detection including nitrogen charging pressure holding joint leak testing complete as per OEM specifications , Providing and Filling of R 410A Gas in Main VRV Unit as per direction and upto satisfaction of Engr in charge , Supply installation testing and commissioning of Printed Circuit Board for VRV indoor unit including replacement wiring testing and making system functional complete as per OEM specifications , Supply installation testing and commissioning of Outdoor Inverter Printed Circuit Board for VRV outdoor unit including replacement wiring testing complete as per OEM specification , Dismantling damaged wiring and providing laying testing and commissioning of new 2 core 2 point 5 sqmm copper cable for VRV VRF system complete with termination and testing as per specifications , Repairing of Indoor Printed Circuit Board for VRV indoor unit including fault diagnosis component replacement servicing testing and making unit functional complete as per OEM specifications , Providing and replacement of indoor fan motor assembly for VRV indoor unit including dismantling installation wiring testing and making unit functional complete as per OEM specifications
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
12
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Panchkula
Delivery Pincodes
134103
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Raj Kumar Nirankari | 134103,Office of the Inspector General BTC, ITBP , BHANU PANCHKULA HARYANA PIN- 134103 | Panchkula | Haryana | 134103 | 3 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Cleaning and servicing of 4 TR tower type air conditioner including cleaning of filters blower coils drain line electrical checks testing and commissioning complete as per OEM specifications
For description of items please refer ATC
Providing and filling of compatible R22 or R32 refrigerant gas for 1 point 5 TR split air conditioner including leak testing and making unit functional complete
For description of items please refer ATC
Nitrogen pressure testing of VRV air conditioning system for leak detection including nitrogen charging pressure holding joint leak testing complete as per OEM specifications
For description of items please refer ATC
Providing and Filling of R 410A Gas in Main VRV Unit as per direction and upto satisfaction of Engr in charge
For description of items please refer ATC
Supply installation testing and commissioning of Printed Circuit Board for VRV indoor unit including replacement wiring testing and making system functional complete as per OEM specifications
For description of items please refer ATC
Supply installation testing and commissioning of Outdoor Inverter Printed Circuit Board for VRV outdoor unit including replacement wiring testing complete as per OEM specification
For description of items please refer ATC
Dismantling damaged wiring and providing laying testing and commissioning of new 2 core 2 point 5 sqmm copper cable for VRV VRF system complete with termination and testing as per specifications
For description of items please refer ATC
Repairing of Indoor Printed Circuit Board for VRV indoor unit including fault diagnosis component replacement servicing testing and making unit functional complete as per OEM specifications
For description of items please refer ATC
Providing and replacement of indoor fan motor assembly for VRV indoor unit including dismantling installation wiring testing and making unit functional complete as per OEM specifications
For description of items please refer ATC
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Cleaning and servicing of 4 TR tower type air conditioner including cleaning of filters blower coils drain line electrical checks testing and commissioning complete as per OEM specifications | For description of items please refer ATC | 3 | job | ocpnr | 30 | |
| 2 | Providing and filling of compatible R22 or R32 refrigerant gas for 1 point 5 TR split air conditioner including leak testing and making unit functional complete | For description of items please refer ATC | 14 | kg | ocpnr | 30 | |
| 3 | Nitrogen pressure testing of VRV air conditioning system for leak detection including nitrogen charging pressure holding joint leak testing complete as per OEM specifications | For description of items please refer ATC | 140 | kg | ocpnr | 30 | |
| 4 | Providing and Filling of R 410A Gas in Main VRV Unit as per direction and upto satisfaction of Engr in charge | For description of items please refer ATC | 102 | kg | ocpnr | 30 | |
| 5 | Supply installation testing and commissioning of Printed Circuit Board for VRV indoor unit including replacement wiring testing and making system functional complete as per OEM specifications | For description of items please refer ATC | 3 | nos | ocpnr | 30 | |
| 6 | Supply installation testing and commissioning of Outdoor Inverter Printed Circuit Board for VRV outdoor unit including replacement wiring testing complete as per OEM specification | For description of items please refer ATC | 2 | nos | ocpnr | 30 | |
| 7 | Dismantling damaged wiring and providing laying testing and commissioning of new 2 core 2 point 5 sqmm copper cable for VRV VRF system complete with termination and testing as per specifications | For description of items please refer ATC | 200 | mtr | ocpnr | 30 | |
| 8 | Repairing of Indoor Printed Circuit Board for VRV indoor unit including fault diagnosis component replacement servicing testing and making unit functional complete as per OEM specifications | For description of items please refer ATC | 5 | job | ocpnr | 30 | |
| 9 | Providing and replacement of indoor fan motor assembly for VRV indoor unit including dismantling installation wiring testing and making unit functional complete as per OEM specifications | For description of items please refer ATC | 6 | nos | ocpnr | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS