Bid Publish Date
10-Aug-2026, 5:04 pm
Bid End Date
01-Sep-2026, 1:00 pm
Progress
A tender has been published for Bhakra Beas Management Board Manual Metal Arc Welding (MMA) Machine (V3) (Q2), Motor Driven Welding Generator (Q3). Quantity: 4 by. Submission Deadline: 01-09-2026 13: 00: 00. Check eligibility and apply.
Quantity
4
Category
Manual Metal Arc Welding (MMA) Machine (V3)
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
3 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Manual Metal Arc Welding (MMA) Machine (V3) (Q2) , Motor Driven Welding Generator (Q3)
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Rupnagar
Delivery Pincodes
140124
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Kaushal Kumar Prajapat | 140124,Bhakra Beas Management Board, XEN STORE POWER WING NANGAL | Rupnagar | Punjab | 140124 | 2 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
01-Sep-2026, 7:30 am
Opening Date
01-Sep-2026, 8:00 am
Discover companies most likely to bid on this tender
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Generic | Technology | Insulated Gate Bipolar Transistor (IGBT) |
| Generic | Power Supply (Tolerance +- 10%) | 415 V Three Phase (50/60Hz) |
| Generic | Maximum Welding Current at 60% duty cycle (In Amp) (Tolerance +- 10%) | 400 |
| Generic | No Load Voltage (In V) | >60<=70 |
| Generic | Rated Welding Voltage (In V) | >30<=40 |
| Generic | Efficiency (In %) | >80<=85, >85<=90 Or higher |
| Generic | Degree of protection (IP) | IP23 |
| Safety | Protection | Single Phasing Protection, Over Temperature, Under Voltage and Over Voltage, Over Current |