TenderDekho Logo
Active GEM

Contract Bidding Open For Echo Cardiography Scanning Machine (V2) in CENTRAL DELHI, DELHI

Bid Publish Date

20-Jul-2026, 12:01 pm

Bid End Date

14-Sep-2026, 7:00 pm

Generate Docs

Progress

Issue20-Jul-2026, 12:01 pm
Corrigendum07-Sep-2026
AwardPending

N/a has released a public tender for Echo Cardiography Scanning Machine (V2) (Q2) in CENTRAL DELHI, DELHI. Quantity: 1. Submission Deadline: 14-09-2026 19: 00: 00. Download documents and apply online.

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

110

OEM Avg. Turnover

230

Past Performance

50 %

Warranty Period

7 days

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Echo Cardiography Scanning Machine (V2) (Q2)

Advisory Bank

Bank Of Baroda

ePBG Percentage

5%

ePBG Duration (Months)

30

Pre-Bid & Qualification

Pre-Bid Date

06-08-2026 14:00:00

Pre-Bid Venue

Office of Dr. Kaushal Kumar Tyagi, Addl Medical Superintendent, Nursing Home, Old Building, Dr. Ram Manohar Lohia Hospital, New Delhi

Delivery Details

Max Delivery Days

90

Delivery Locations

1

Delivery Cities

New Delhi

Delivery Pincodes

110001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Harikesh Meena110001,dr. ram manohar lohia hospital baba kharak singh marg new delhiNew DelhiDelhi110001190-

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 6

GeM-Bidding-9623669.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Authority & Contact

Organization

N/a

Office Name

Dr. Ram Manohar Lohia Hospital, New Delhi

Grievance Contact

[email protected]

Corrigendum Updates

1 Update
#1

Update

07-Sep-2026

Extended Deadline

14-Sep-2026, 1:30 pm

Opening Date

15-Sep-2026, 1:30 pm

Categories 3

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Types of Probes & Features Cardiac and Vascular Probes Configuration TTE Phased Array, TTE Matrix Array, TEE Phased Array, TEE Matrix Array, Linear Probe
Types of Probes & Features TTE(Transthoracic) Probe Type Adult, Pediatric, Neonatal
Types of Probes & Features TEE Adult Probe biplane and Multiplane frequency, in MHz 2 to 7.5 MHz (±2), Not Applicable
Types of Probes & Features TEE Pediatric Probe Required Yes, No
Types of Probes & Features TEE Pediatric Probe frequency, in MHz 3 to 8 MHz (±2), Not Applicable
Types of Probes & Features Linear Probe for linear/ vascular applications required Yes
Types of Probes & Features Adult/Pediatric Linear probe frequency in MHz 5 to 14 MHz (±2)
Types of Probes & Features No of Adult TTE Probes Required 1
Types of Probes & Features No of Pediatric TTE Probes Required 1
Types of Probes & Features No of Neonatal TTE Probes Required 1
Types of Probes & Features No of Adult TEE Probes Required 1, NA
Types of Probes & Features No of Pediatric TEE Probes Required 1, NA
Types of Probes & Features No of Pediatric 3D/4D TEE Probes Required 1, NA
Types of Probes & Features No of Neonatal TEE Probes Required 1, NA
Types of Probes & Features No of Adult/pediatric Linear Probes supplied 1, NA
Types of Probes & Features Dedicated 3D/4D volume imaging for cardiology TTE ad TEE Yes, No
Types of Probes & Features Live 3 D imaging in color doppler system Yes
Types of Probes & Features Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval Yes, No
Types of Probes & Features Provision of Tissue Colorization (B-Colour) for improved contrast resolution Yes
Types of Probes & Features Application software Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications
Types of Probes & Features Cine Loop Features Yes
Types of Probes & Features Frame grabber facility for post analysis Yes
Types of Probes & Features Facility of Various maps for pre and post processing Yes
Types of Probes & Features ECG trigger facility Yes
Types of Probes & Features User defined Preset Yes
Types of Probes & Features Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography Yes
Types of Probes & Features Number of transducer/probe ports 3
Scan Modes and Performance Parameters Cardiac 3-D freehand Option Yes, No
Scan Modes and Performance Parameters Cardiac 3D/4D automatic Option Yes
Scan Modes and Performance Parameters Contrast Harmonic/Agent Imaging with angio mode Yes
Scan Modes and Performance Parameters Color Doppler 3-D/4-D option Yes
Scan Modes and Performance Parameters Power Dopple 3-D/4-D option Yes
Scan Modes and Performance Parameters Contrast-enhanced ultrasound (CEUS) option Yes, No
Scan Modes and Performance Parameters Tissue synchronization, tissue velocity Yes
Scan Modes and Performance Parameters Cardiac Shear wave elastography Yes, No
Scan Modes and Performance Parameters Cardiac compression elastography Yes, No
Scan Modes and Performance Parameters Provision for higher sensitivity for low frequency doppler in all probes Yes
Scan Modes and Performance Parameters Latest generation Electronic Phased/sector array Colour Doppler system Yes
Scan Modes and Performance Parameters Number of Channels in color doppler system 500000 or more (if channels are being designated as digital channels)
Scan Modes and Performance Parameters System should be capable of generating real time live 3- D images Yes
Image display and processing DICOM 3 Compliant Yes
Image display and processing Automated B-mode (2-D) image Yes
Image display and processing Automated CDI image optimization Yes
Image display and processing Automated PW Doppler image optimization Yes
Image display and processing Touch Screen No
Image display and processing Monitor display size, cm (in) 21 Inch(±1) Or higher
Image display and processing Split screen Twin View and Live Quad Screen
Image display and processing Single/dual monitors Dual (image display on touch panel)
Image display and processing Speckle-tracking strain and strain rate Yes
Image display and processing Analysis and calculation packages 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No
Image display and processing Type of printer provided with the echo cardio machine Themal Printer, B/W Laser Printer, Color Laser Printer
Image display and processing Type of processor in PC i7 or Latest
Image display and processing Conectivity between Echo cardiogram and PC Through IMS/Equivalent Software
Image display and processing PC with all software inclusive interfaced with echocardiograph machine Yes
Image display and processing Inkjet printer provided with computer for reporting No
Image display and processing Glossy Colour Print Paper supplied 500 sheets
Image display and processing ECG Cable 2
Image display and processing Echo cardiography sytem to be DICOM Ready Yes
Image display and processing Dicom Interfacability to HIS Yes
Image display and processing Dicom Interfacability Dicom to PACS Yes
Image display and processing Interfacability Dicom to RIS Yes, No