Progress
Quantity
6815
Category
Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa
Bid Type
Two Packet Bid
A tender has been published for Indian Army Excavation in treches in soft and loose soil not exceeding 1 poin 5 meter wide and depth, Returning filling trenches including spreading levelling, Removing of excavated material soil to a distance not exceeding 50 Mtr, M and L Sand cushioning to UG cables, M and L for precast concrete cable covers type 2 flat size 250mmx150mmx40mm, M and L cable cover class HV type 1 flat size 300 mm X 180mm x 40mm, Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa, M AND L for Earthing complete with 32x6 GI stip, SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 95 sqmm, SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 240 sqmm, SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 95 sqmm, SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 240 sqmm, M and taking out disconnecting of diffrent capacities transformer from foundation or 4 pole structure, SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 200 Kva, SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 315 kVA, SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 400 kVA, SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 500 kVA, M and L for provision of transformer plinth of size 2 point 5 x 2 point 5 mtrs with fencing, M and L for MS tube light grade galvanised of size 80 mm dia, M and L for MS tube light grade galvanised of size 100 mm dia, XLPE Cable for Working Voltage up to and Including 1. 1 KV Marked To IS 7098 (Part 1) (Q2), XLPE Cable, Working Voltage from 3. 3 kV up to and including 33 kV (V2) ISI Marked to IS 7098 (Part 2) (Q2) in PATIALA, PUNJAB. Quantity: 6815 by. Submission Deadline: 03-08-2026 17: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Excavation in treches in soft and loose soil not exceeding 1 poin 5 meter wide and depth , Returning filling trenches including spreading levelling , Removing of excavated material soil to a distance not exceeding 50 Mtr , M and L Sand cushioning to UG cables , M and L for precast concrete cable covers type 2 flat size 250mmx150mmx40mm , M and L cable cover class HV type 1 flat size 300 mm X 180mm x 40mm , Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa , M AND L for Earthing complete with 32x6 GI stip , SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 95 sqmm , SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 240 sqmm , SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 95 sqmm , SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 240 sqmm , M and taking out disconnecting of diffrent capacities transformer from foundation or 4 pole structure , SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 200 Kva , SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 315 kVA , SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 400 kVA , SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 500 kVA , M and L for provision of transformer plinth of size 2 point 5 x 2 point 5 mtrs with fencing , M and L for MS tube light grade galvanised of size 80 mm dia , M and L for MS tube light grade galvanised of size 100 mm dia , XLPE Cable for Working Voltage up to and Including 1.1 KV Marked To IS 7098 (Part 1) (Q2) , XLPE Cable, Working Voltage from 3.3 kV up to and including 33 kV (V2) ISI Marked to IS 7098 (Part 2) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
22
Max Delivery Days
180
Delivery Locations
1
Delivery Cities
Patiala
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| - | Patiala | Patiala | - | - | 285 | 180 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Excavation in treches in soft and loose soil not exceeding 1 poin 5 meter wide and depth
Excavation in treches in soft and loose soil not exceeding 1 poin 5 meter wide and depth
Returning filling trenches including spreading levelling
Returning filling trenches including spreading levelling
Removing of excavated material soil to a distance not exceeding 50 Mtr
Removing of excavated material soil to a distance not exceeding 50 Mtr
M and L Sand cushioning to UG cables
M and L Sand cushioning to UG cables
M and L for precast concrete cable covers type 2 flat size 250mmx150mmx40mm
M and L for precast concrete cable covers type 2 flat size 250mmx150mmx40mm
M and L cable cover class HV type 1 flat size 300 mm X 180mm x 40mm
M and L cable cover class HV type 1 flat size 300 mm X 180mm x 40mm
Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa
Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa
M AND L for Earthing complete with 32x6 GI stip
M AND L for Earthing complete with 32x6 GI stip
SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 95 sqmm
SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 95 sqmm
SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 240 sqmm
SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 240 sqmm
SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 95 sqmm
SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 95 sqmm
SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 240 sqmm
SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 240 sqmm
M and taking out disconnecting of diffrent capacities transformer from foundation or 4 pole structure
M and taking out disconnecting of diffrent capacities transformer from foundation or 4 pole structure
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 200 Kva
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 200 Kva
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 315 kVA
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 315 kVA
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 400 kVA
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 400 kVA
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 500 kVA
SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 500 kVA
M and L for provision of transformer plinth of size 2 point 5 x 2 point 5 mtrs with fencing
M and L for provision of transformer plinth of size 2 point 5 x 2 point 5 mtrs with fencing
M and L for MS tube light grade galvanised of size 80 mm dia
M and L for MS tube light grade galvanised of size 80 mm dia
M and L for MS tube light grade galvanised of size 100 mm dia
M and L for MS tube light grade galvanised of size 100 mm dia
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Excavation in treches in soft and loose soil not exceeding 1 poin 5 meter wide and depth | Excavation in treches in soft and loose soil not exceeding 1 poin 5 meter wide and depth | 285 | cum | genorthpatiala | 180 | |
| 2 | Returning filling trenches including spreading levelling | Returning filling trenches including spreading levelling | 193 | cum | genorthpatiala | 180 | |
| 3 | Removing of excavated material soil to a distance not exceeding 50 Mtr | Removing of excavated material soil to a distance not exceeding 50 Mtr | 92 | cum | genorthpatiala | 180 | |
| 4 | M and L Sand cushioning to UG cables | M and L Sand cushioning to UG cables | 62 | cum | genorthpatiala | 180 | |
| 5 | M and L for precast concrete cable covers type 2 flat size 250mmx150mmx40mm | M and L for precast concrete cable covers type 2 flat size 250mmx150mmx40mm | 3,200 | each | genorthpatiala | 180 | |
| 6 | M and L cable cover class HV type 1 flat size 300 mm X 180mm x 40mm | M and L cable cover class HV type 1 flat size 300 mm X 180mm x 40mm | 1,600 | each | genorthpatiala | 180 | |
| 7 | Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa | Boring of holes under road including HDPE pipe of 150 mm dia suitable for 0 point 4 mpa | 25 | rm | genorthpatiala | 180 | |
| 8 | M AND L for Earthing complete with 32x6 GI stip | M AND L for Earthing complete with 32x6 GI stip | 24 | each set | genorthpatiala | 180 | |
| 9 | SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 95 sqmm | SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 95 sqmm | 3 | each | genorthpatiala | 180 | |
| 10 | SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 240 sqmm | SITC Cable jointing kit for 11 KV outdoor heat shrink XLPE 3 core x 240 sqmm | 3 | each | genorthpatiala | 180 | |
| 11 | SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 95 sqmm | SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 95 sqmm | 2 | each | genorthpatiala | 180 | |
| 12 | SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 240 sqmm | SITC Cable jointing kit for 11 KV indoor heat shrink XLPE 3 core x 240 sqmm | 2 | each | genorthpatiala | 180 | |
| 13 | M and taking out disconnecting of diffrent capacities transformer from foundation or 4 pole structure | M and taking out disconnecting of diffrent capacities transformer from foundation or 4 pole structure | 8 | each job | genorthpatiala | 180 | |
| 14 | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 200 Kva | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 200 Kva | 1 | each | genorthpatiala | 180 | |
| 15 | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 315 kVA | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 315 kVA | 2 | each | genorthpatiala | 180 | |
| 16 | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 400 kVA | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 400 kVA | 4 | each | genorthpatiala | 180 | |
| 17 | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 500 kVA | SITC of outdoor type transformer 11kv to 433 volts Level 2 afficiency 500 kVA | 1 | each | genorthpatiala | 180 | |
| 18 | M and L for provision of transformer plinth of size 2 point 5 x 2 point 5 mtrs with fencing | M and L for provision of transformer plinth of size 2 point 5 x 2 point 5 mtrs with fencing | 8 | each job | genorthpatiala | 180 | |
| 19 | M and L for MS tube light grade galvanised of size 80 mm dia | M and L for MS tube light grade galvanised of size 80 mm dia | 10 | rm | genorthpatiala | 180 | |
| 20 | M and L for MS tube light grade galvanised of size 100 mm dia | M and L for MS tube light grade galvanised of size 100 mm dia | 10 | rm | genorthpatiala | 180 |
| Category | Specification | Requirement |
|---|---|---|
| STANDARD | Cables suitable for use in mines | No |
| GENERIC | Classification of cables for improved fire performace category | 01 |
| GENERIC | Nominal Area of Conductor (in Sq mm) | 300 |
| GENERIC | Number of Cores | 3.5 |
| CONSTRUCTION | Material of Conductor | Aluminium |
| CONSTRUCTION | Construction of the conductor | Stranded and shaped |
| CONSTRUCTION | Type of Inner Sheath | Thermoplastic |
| ARMOURING | Type of Cable | Armoured cable |
| ARMOURING | Material of Armouring | Galvanized steel formed wire |
| ARMOURING | Type of Armouring | Single strip |
| IDENTIFICATION ON CABLE | Type of Sequential Marking on Cable | Screen printing on cable |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
BOQ
BOQ
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS