High End Multipara Monitor (V3)
Ssg Hospital Vadodara
VADODARA, GUJARAT
Bid Publish Date
11-Jun-2026, 3:49 pm
Bid End Date
02-Jul-2026, 3:00 pm
EMD
₹10,800
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Tata Memorial Centre invites bids for High End Multipara Monitor (V3) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 1. Submission Deadline: 02-07-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
High End Multipara Monitor (V3) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
TECHNICAL
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Ssg Hospital Vadodara
VADODARA, GUJARAT
Directorate Of Medical Education And Training
SIDDHARTHNAGAR, UTTAR PRADESH
Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)
THIRUVANANTHAPURAM, KERALA
N/a
KRISHNAGIRI, TAMIL NADU
All India Institute Of Medical Sciences (aiims)
RAIPUR, CHHATTISGARH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Product Specifications | Type of Monitor | Modular |
| Product Specifications | Monitoring Parameters | ECG, HR, Respiration Rate, SpO2, Pulse Rate, NIBP, Temperature, IBP |
| Product Specifications | EtCO2 | Yes |
| Product Specifications | Cardiac output | NA |
| Product Specifications | Transport monitor module with basic vital parameters for transporting within the hospital | Yes |
| Product Specifications | Screen size of transport module( in inches ) | 4.3 inch or more |
| Product Specifications | Battery backup for transport monitor ( in hrs) | 3 or more |
| Product Specifications | AGM (Anesthetic Gas Module) | Upgradable |
| Product Specifications | NMT (Neuro Muscular Transmission) | No |
| Product Specifications | EEG (Electroencephalogram) | Upgradable |
| Product Specifications | AEEG (Amplitude Integrated Electroencephalography)Trend Graph | No |
| Product Specifications | Channels in EEG | 2 |
| Product Specifications | Depth of Anesthesia Monitoring | Upgradable |
| Product Specifications | Spirometry | Upgradable |
| Product Specifications | Non invasive hemoglobin | No |
| Product Specifications | PVI (Pleth variability index) | No |
| Product Specifications | Perfusion Index | Yes |
| Product Specifications | Transcutaneous PO2 / PCO2 | No |
| Product Specifications | S T Analysis | Yes |
| Product Specifications | PPV (derived value during IBP measurement) | Yes |
| Product Specifications | Regional Oximetry | Upgradable |
| Product Specifications | Length of time of full disclosure of patient data in hr | ≥ 48, ≥ 72 Or higher |
| Product Specifications | Length of time of trending in hr | ≥ 72 Or higher |
| Generic | Product Description | High End Multipara Monitor |
| ECG PARAMETERS | ECG Provided | Yes |
| ECG PARAMETERS | Number of leads of ECG | 5 |
| ECG PARAMETERS | 12-Lead interpretation for ECG | No |
| ECG PARAMETERS | ECG Waveform number of leads display | 7 |
| ECG PARAMETERS | Arrhythmia detect | Yes |
| ECG PARAMETERS | Heart rate measurement range | Atleast 30 -250 bpm |
| ECG PARAMETERS | Accuracy | ± 2 bpm or better |
| ECG PARAMETERS | Minimum gradation | 1 bpm or better |
| RESPIRATION PARAMETERS | Respiration Method | Impedance pneumography |
| RESPIRATION PARAMETERS | Display waveform of respiration | Yes |
| RESPIRATION PARAMETERS | Respiration rate measurement range | 0 - 100 bpm or more |
| RESPIRATION PARAMETERS | Minimum gradation of respiratory measurement | 1 bpm or better |
| PULSE OXIMETERY PARAMETERS | Measurement technique (Declaration of the measurement technique by the seller at the time of bid submission/supply) | Low Perfusion Technology with Motion artifact detection |
| PULSE OXIMETERY PARAMETERS | Probe type | Clip |
| PULSE OXIMETERY PARAMETERS | Probe for Adult and Pediatric | Reusable |
| PULSE OXIMETERY PARAMETERS | Probe for neonates | Reusable |
| PULSE OXIMETERY PARAMETERS | SPO2 measurement range | 40 - 100% |
| PULSE OXIMETERY PARAMETERS | Accuracy of SPO2 measurement | ± 2% or better |
| PULSE OXIMETERY PARAMETERS | Minimum Gradation | 1% |
| NIBP PARAMETERS | Measurement technique for NIBP | Step-deflation Oscillometric / Linear Inflation |
| NIBP PARAMETERS | Systolic Blood pressure monitoring range | 40 - 270 mmHg or more |
| NIBP PARAMETERS | Diastolic Blood pressure monitoring range | 30 - 220 mmHg or more |
| NIBP PARAMETERS | Accuracy of NIBP Measurement | ±3 mm/Hg or better |
| TEMPERATURE PARAMETERS | Number of channels for temperature | 2 |
| TEMPERATURE PARAMETERS | Type of probe | Skin |
| TEMPERATURE PARAMETERS | Temperature probe type | Reusable |
| TEMPERATURE PARAMETERS | Temperature probe range | Atleast 30 - 40 degree |
| TEMPERATURE PARAMETERS | Minimum gradation of temperature probe | 0.1 degree C or better |
| TEMPERATURE PARAMETERS | Accuracy in % | ±1% or better |
| IBP PARAMETERS | Number of channels for IBP | 2 |
| ETCO2 PARAMETERS | Sensor type | Sidestream |
| ETCO2 PARAMETERS | Patient type | Intubated |
| ETCO2 PARAMETERS | CO2 Measuring range ( in mmHg ) | 0 to 99 mmHg or better |
| ALARMS | Availability of Audio and visual alarms with high , medium and low intensity adjustment | Yes |
| ALARMS | Operator can set audio visual alarm levels for low or high levels of each parameter independently | Yes |
| ALARMS | Systolic BP - low and high | Yes |
| ALARMS | Diastolic BP - low and high | Yes |
| ALARMS | Mean BP - low and high | Yes |
| ALARMS | Heart rate - low and high | Yes |
| ALARMS | SPO2 - low and high | Yes |
| ALARMS | Respiratory rate - low and high | Yes |
| ALARMS | Temperature - low and high | Yes |
| ALARMS | Alarm Volume Adjustable | Yes |
| ALARMS | Activating silence of alarm | Yes |
| ALARMS | Duration of alarm silence ( in seconds ) | 120 |
| ALARMS | Suspension of all alarms | Yes |
| ALARMS | Latching of alarm | No |
| ALARMS | Cuff leakage alarm | Yes |
| ALARMS | Cuff disconnect alarm | Yes |
| ALARMS | Alarm for inflation/deflation errors | Yes |
| ALARMS | Indicator for low-battery | Yes |
| ALARMS | EtCO2 - low and high | Yes |
| ALARMS | Escalation of Alarm Priority | Yes |
| ALARMS | Sensor/ wire/probe disconnection alarm | Yes |
| NETWORK PARAMETERS | Ethernet port | Yes |
| NETWORK PARAMETERS | Hardwired | Yes |
| NETWORK PARAMETERS | Wireless | Yes |
| NETWORK PARAMETERS | Connectivity with Network printer | No |
| NETWORK PARAMETERS | Connectivity provision with Central Nursing Station | Yes |
| DISPLAY PARAMETERS | Type of display | LCD/LED/TFT |
| DISPLAY PARAMETERS | Display Size in inches | 15, 17, 19 Or higher |
| DISPLAY PARAMETERS | Traces of display | >10 |
| DISPLAY PARAMETERS | User Interface of display | Touchscreen, Touchscreen and Rotary knob Or higher |
| DISPLAY PARAMETERS | Inbuilt thermal Recorder (Printer) | No |
| DISPLAY PARAMETERS | Should be able to connect to additional display | No |
| STANDARD ACCESSORIES | Number of reusable adult probe provided | 1 |
| STANDARD ACCESSORIES | Number of reusable pediatric probe provided | NA |
| STANDARD ACCESSORIES | Number of reusable neonatal probe provided | NA |
| STANDARD ACCESSORIES | Number of Disposable neonate probes provided | NA |
| STANDARD ACCESSORIES | Number of ECG 5/6/10 lead cable provided | 1 |
| STANDARD ACCESSORIES | Number of Neonatal ECG 3/5/6 lead cable provided | Not Provided |
| STANDARD ACCESSORIES | Number of IBP cables provided | 2 Reusable Cables |
| STANDARD ACCESSORIES | Number of disposable IBP Transducers provided | 5 |
| STANDARD ACCESSORIES | Number of Adult NIBP cuffs of Medium, Large, Extra large provided | 1 Set |
| STANDARD ACCESSORIES | Number of Pediatric NIBP cuffs of Small and medium provided | 1 Set |
| STANDARD ACCESSORIES | Number of Disposable Neonate NIBP cuffs of 1,2,3,4,5 (in cm) provided | NA |
| STANDARD ACCESSORIES | Number of Skin temperature probe provided | 1 for Adult / Paediatric |
| STANDARD ACCESSORIES | Number of Neonatal Rectal temperature Probe provided | NA |
| STANDARD ACCESSORIES | Number of Esophageal Temperature probe (Adult) provided | NA |
| STANDARD ACCESSORIES | Number of EtCO2 adapter provided | NA |
| STANDARD ACCESSORIES | Number of EtCO2 Sampling Line provided | NA |
| STANDARD ACCESSORIES | Number of Water trap provided | NA |
| STANDARD ACCESSORIES | Accessories to wall mount the monitor | Yes |
| POWER REQUIREMENTS | Power supply | Single Phase 220-240 VAC, 50Hz |
| POWER REQUIREMENTS | Mains cable | 3 meter or more with Indian plug |
| POWER REQUIREMENTS | Battery | Inbuilt |
| POWER REQUIREMENTS | Minimum Back up time of UPS ( in minutes ) | NA |
| POWER REQUIREMENTS | Minimum Inbuilt Battery back up ( in minutes ) | 120 |
| POWER REQUIREMENTS | Recharging time of battery ( in hr ) | ≤ 6 |
| POWER REQUIREMENTS | Weight of the Machine in kgs | ≤ 15 |
| POWER REQUIREMENTS | Noise level ( in dB ) | ≤ 50 |
| POWER REQUIREMENTS | Device Earthing | Yes |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Conformity to Electrical Safety Standards | IEC 60601 or BIS Equivalent |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow
📍 LUCKNOW, UTTAR PRADESH
South Eastern Coalfields Limited
📍 BILASPUR, CHHATTISGARH
Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow
📍 LUCKNOW, UTTAR PRADESH
Sign up now to access all documents
Main Document
TECHNICAL
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS