TenderDekho Logo
GEM

Contract Bidding Open For Real Time PCR Machine (V2) in KAMRUP, ASSAM

Bid Publish Date

02-Feb-2026, 12:34 pm

Bid End Date

02-Mar-2026, 1:00 pm

EMD

₹64,000

Location

Latest Corrigendum Available

Progress

Issue02-Feb-2026, 12:34 pm
Corrigendum23-Feb-2026
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 2

A tender has been published for N/a Real Time PCR Machine (V2) (Q2) in KAMRUP, ASSAM. Quantity: 1 by. Submission Deadline: 02-03-2026 13: 00: 00. Check eligibility and apply.

Documents 4

GeM-Bidding-8906129.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Real Time PCR Machine (V2)

All India Institute Of Medical Sciences (aiims)

JODHPUR, RAJASTHAN

Posted: 9 October 2025
Closed: 30 October 2025
GEM

Regional Ayurveda Research Institute for Drug Development Real Time PCR Machine Tender Gwalior Madhya Pradesh 2025 IS 550 compliant

Regional Ayurveda Research Institute For Drug Deve

GWALIOR, MADHYA PRADESH

Posted: 18 October 2025
Closed: 15 November 2025
GEM

Real Time PCR Machine (V2)

Indian Institute Of Technology (iit)

WEST DELHI, DELHI

Posted: 10 December 2025
Closed: 20 December 2025
GEM

Real Time PCR Machine (V2)

Central University Of Jammu

Samba, JAMMU & KASHMIR

Posted: 8 April 2025
Closed: 18 April 2025
GEM

Real Time PCR Machine (V2)

Agharkar Research Institute (ari)

PUNE, MAHARASHTRA

Posted: 7 March 2025
Closed: 22 March 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERAL INFORMATION Product Name Real Time PCR Machine
PRODUCT INFORMATION System Type Open
PRODUCT INFORMATION Capacity of Blocks 96 well
PRODUCT INFORMATION Number of channels (minimum) 6
PRODUCT INFORMATION Maximum Heating ramp rate in degree per second 4, 5, 6
PRODUCT INFORMATION Maximum Cooling ramp rate in degree per second 4, 5, 6
PRODUCT INFORMATION Adjustable heating / cooling ramp rate Yes Or higher
PRODUCT INFORMATION Operating Temperature range (degree celcius) 4 - 105 degree celcius
PRODUCT INFORMATION Hot Lid Temperature (degree celcius) 30 to 110 degree celcius
PRODUCT INFORMATION Sample volume range in micro litre 5 to 100 ml
PRODUCT INFORMATION Programmable Steps and cycles Yes
PRODUCT INFORMATION Number of USB ports 2, 3, 4
PRODUCT INFORMATION Pause / Start function Yes
PRODUCT INFORMATION Input power supply Single phase (230 V, 50 Hz)
PRODUCT INFORMATION Auto restart after power outages Yes
PRODUCT INFORMATION Boot up time ≤1 minute
PRODUCT INFORMATION Type of chemistries that can be run on system Taqman, SYBR green, Molecular Beacon and all other fluorescent dye based
PRODUCT INFORMATION Compatibility for well strips 8, 96
PRODUCT INFORMATION Compatibility for Individual PCR tubes 0.1 to 0.2 ml tubes
PRODUCT INFORMATION Addition of new dyes should be possible without hardware change Yes
PRODUCT INFORMATION Analysis performed Gene Expression, Plus/minus assay, SNP, Allelic Discrimination and Dissociation Curve Analysis, DNA Quantitation, Gene Expression Analysis, Comparative Analysis Curve, Standard Curve/ Relative Standard Curve
PRODUCT INFORMATION Instrument software should not restrict number of assay or target that can be run on a single 96 well plate in parallel Yes
PRODUCT INFORMATION Suitable software for Data Acquisition, analysis of run and also for Gene Expression analysis by relative quantity or normalized expression Yes
PRODUCT INFORMATION Software should have the capacity to analyze data of minimum 10 different runs at a time Yes
PRODUCT INFORMATION The instrument software must be capable of detecting and analyzing a different gene, SNP or pathogen target in every well of the 96-well plate Yes
PRODUCT INFORMATION Temperature setting accuracy (degree celcius) ± 0.2, ± 0.3
PRODUCT INFORMATION Well to well temperature uniformity (degree celcius) ± 0.3, ± 0.4
DATA MANAGEMENT SYSTEM Computer system with latest licensed operating system and antivirus provided Yes
DATA MANAGEMENT SYSTEM PC monitor type LCD / LED
DATA MANAGEMENT SYSTEM Minimum PC monitor size (inches) 15 Inches or more
DATA MANAGEMENT SYSTEM PC hard disk 500 GB, 1 TB Or higher
CERTIFICATIONS Certification for manufacturing unit ISO:13485 (Latest)
CERTIFICATIONS Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date Yes
CERTIFICATIONS Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement Yes
CERTIFICATIONS Electrical Safety Compliance Standard IEC 60601 or Equivalent BIS
WARRANTY Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 5 Or higher

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

1 Update
#1

Update

23-Feb-2026

Extended Deadline

02-Mar-2026, 1:00 pm

Opening Date

02-Mar-2026, 1:30 pm