GEM

Open Tender for C73340100470 Supply of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-A in GHAZIABAD, UTTAR PRADESH

Bid Publish Date

16-Dec-2025, 2:21 pm

Bid End Date

29-Dec-2025, 12:00 pm

Progress

Issue16-Dec-2025, 2:21 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

579

Category

C73340100470 Supply of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-A

Bid Type

Two Packet Bid

Categories 39

A tender has been published for Bharat Electronics Limited (bel) C73340100470 Supply of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-A, 100000000000 Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2TR Cassette ACorSplit AC unit refer annexure II-A, 100000000001 Providing flexible PVC Duct hose Covering pipe gray colour of size 60 mm refer annexure II-A, 100000000002 ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-A, 100000000003 Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-A, 100000000004 Supply of following size LT power cable with Copper conductor XLPEorPVC insulation refer annexure II-A, 100000000005 Supply of Copper cable of size 4 core - 2point5 sq mmfor communication refer annexure II-A, 100000000006 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure II-A, 100000000007 Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-B, 100000000008 Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units for 2 Cassette AC unit refer annexure II-B, 100000000009 Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm refer annexure II-B, 100000000010 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-B, 100000000011 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-B, 100000000012 Laying of following size LT power cable with Copper conductor refer annexure II-B, 100000000013 Laying of Copper cable of size 4 core - 2point5 sq mm for communication refer annexure II-B, 100000000014 Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure II-B, 100000000015 Dismantling and shifting of existing Cassette AC 4 nos including associated supprots Cu piping etc refer annexure II-B in GHAZIABAD, UTTAR PRADESH. Quantity: 579 by. Submission Deadline: 29-12-2025 12: 00: 00. Check eligibility and apply.

Past Similar Tenders (Historical Results)

5 found

20 HP outdoor VRV OR VRF,10 HP outdoor VRV OR VRF,4 Way 4.0 Tr VRF Cassette Indoor,4 Way 2.0 Tr VRF

State Bank Of India (sbi)

LUCKNOW, UTTAR PRADESH

Posted: 5 June 2025
Closed: 18 June 2025
GEM

Supply of 3TR metal body copper coil evaporator and copper coil condenser Ductable AC units,Install

Bharat Sanchar Nigam Limited Portal(bsnl)

CUTTACK, ODISHA

Posted: 20 February 2025
Closed: 7 March 2025
GEM

Supply of 4 TR vertical split type air conditioner of floor mounting,Supply of 2 TR Split DC Invert

Airports Authority Of India

Posted: 6 February 2025
Closed: 6 March 2025
GEM

Variable Refrigerant Flow System side discharge,VRF 4-WAY CASSETTE,VRF 4-WAY CASSETTE,REFNETS,REMOT

Canara Bank

AGRA, UTTAR PRADESH

Posted: 30 July 2025
Closed: 19 August 2025
GEM

Supply of 1.5 TR Invertor ductable AC,Supply of 3.0 TR Invertor ductable AC,ITC of 1.5 TR ductable

Bharat Sanchar Nigam Limited Portal(bsnl)

BHOPAL, MADHYA PRADESH

Posted: 7 August 2025
Closed: 27 August 2025
GEM

Bill of Quantities (BOQ) 17 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 C73340100470 Supply of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-A Supply of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-A 4 nos con5.bel.gzb 45
2 100000000000 Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2TR Cassette ACorSplit AC unit refer annexure II-A Supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2TR Cassette ACorSplit AC unit refer annexure II-A 60 rmt con5.bel.gzb 45
3 100000000001 Providing flexible PVC Duct hose Covering pipe gray colour of size 60 mm refer annexure II-A Providing flexible PVC Duct hose Covering pipe gray colour of size 60 mm refer annexure II-A 15 rmt con5.bel.gzb 45
4 100000000002 ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-A ProvidingcPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-A 20 rmt con5.bel.gzb 45
5 100000000003 Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-A Providing cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-A 20 rmt con5.bel.gzb 45
6 100000000004 Supply of following size LT power cable with Copper conductor XLPEorPVC insulation refer annexure II-A Supply of following size LT power cable with Copper conductor XLPEorPVC insulation refer annexure II-A 60 rmt con5.bel.gzb 45
7 100000000005 Supply of Copper cable of size 4 core - 2point5 sq mmfor communication refer annexure II-A Supply of Copper cable of size 4 core - 2point5 sq mmfor communication refer annexure II-A 60 rmt con5.bel.gzb 45
8 100000000006 Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure II-A Supply of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure II-A 50 rmt con5.bel.gzb 45
9 100000000007 Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-B Installation testing and commissioning of Cassette AC four way capacity 2 TR minimum 5 star rating refer annexure II-B 4 nos con5.bel.gzb 45
10 100000000008 Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units for 2 Cassette AC unit refer annexure II-B Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units for 2 Cassette AC unit refer annexure II-B 60 rmt con5.bel.gzb 45
11 100000000009 Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm refer annexure II-B Laying of flexible PVC Duct hose Covering pipe gray colour of size 60 mm refer annexure II-B 15 rmt con5.bel.gzb 45
12 100000000010 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-B Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-B 20 rmt con5.bel.gzb 45
13 100000000011 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-B Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure II-B 20 rmt con5.bel.gzb 45
14 100000000012 Laying of following size LT power cable with Copper conductor refer annexure II-B Laying of following size LT power cable with Copper conductor refer annexure II-B 60 rmt con5.bel.gzb 45
15 100000000013 Laying of Copper cable of size 4 core - 2point5 sq mm for communication refer annexure II-B Laying of Copper cable of size 4 core - 2point5 sq mm for communication refer annexure II-B 60 rmt con5.bel.gzb 45
16 100000000014 Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure II-B Installing of perforated Hot Dipped Galvanised Iron cable tray of size150 mm width X 50 mm depth X 1point6 mm thickness refer annexure II-B 50 rmt con5.bel.gzb 45
17 100000000015 Dismantling and shifting of existing Cassette AC 4 nos including associated supprots Cu piping etc refer annexure II-B Dismantling and shifting of existing Cassette AC 4 nos including associated supprots Cu piping etc refer annexure II-B 1 lot con5.bel.gzb 45

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

2

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

2 found
Urgent

SITC of horizontal split casing centrifugal pump sets,Supplying laying fixing testing and commissio

Bharat Sanchar Nigam Limited Portal(bsnl)

📍 CENTRAL DELHI, DELHI

EMD: ₹19,477
Est: ₹9.7 L
⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM
Urgent

BEML Department of Defence Production CPVC & GI Fittings Tender Maharashtra 2025

Bharat Earth Movers Limited (beml)

📍 BANGALORE, KARNATAKA

Est: ₹11.9 L
⏰ Deadline: 3 days left
🛒 Type: Goods
View GEM