E-municipalities Uttar Pradesh LED Electrical Repairs Tender Sitapur UP 2026 – IS/LED Light Bracket Clamp Installation 2026
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
SITAPUR, UTTAR PRADESH
Progress
Quantity
362
Category
MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD
Bid Type
Two Packet Bid
Indian Army has released a public tender for MISC REPAIR MAINTAINCE OF ELECTRIC, MISC REPAIR MAINTAINCE OF WATER SUPPLY INSTALLATION, INSTALLATION IMRPOVEMENT OF EARTHING INFRA, FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD, MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD in HYDERABAD, TELANGANA. Quantity: 362. Submission Deadline: 12-08-2025 11: 00: 00. Download documents and apply online.
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
SITAPUR, UTTAR PRADESH
Government Organization
SITAPUR, UTTAR PRADESH
Government Organization
SITAPUR, UTTAR PRADESH
Marketing Division
KAMRUP, ASSAM
E-IN-C BRANCH - MILITARY ENGINEER SERVICES
HYDERABAD, TELANGANA
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | MISC REPAIR MAINTAINCE OF ELECTRIC | S&F in repair replacement of old earthing with advanced chemical earthing system using pipe-in-pipe technology encapsulated with crystalline conductive compound (CCC), ..... further as per SoW. | 12 | each | ageusec | 15 |
| 2 | MISC REPAIR MAINTAINCE OF WATER SUPPLY INSTALLATION | S&F in repair/ replacment of Lighting arrestor rod with ESE type lighting arrestor with radius of protection up to 55-60 meter height not less than 321 mm, width range 100 mm to 105 mm ,dia of rod 18-20 mm confirming to NFC 17-102 complete all as specified and directed.Make As per GE recommendation | 2 | each | ageusec | 15 |
| 3 | INSTALLATION IMRPOVEMENT OF EARTHING INFRA | M&L in repair/ replacment for Earth Bars 6 way With Twin Disconnecting Link Made out of 50 x 6 mm pure copper bar pre-fitted on epoxy powder coated metal or plastic base mounted on insulators . Make As per GE recommendation | 4 | each | ageusec | 15 |
| 4 | FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment PVC Covered High Conductivity copper Tapes/Strip of size 25x3 mm Complete all as specified and directed. Make As per GE recommendation | 125 | rm | ageusec | 15 |
| 5 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment Lightning Strike Counter To protect the systems against the transient overvoltage (lightning) Digital Type With Li Battery Backup complete all as specified. Make As per GE recommendation | 2 | each | ageusec | 15 |
| 6 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment Back Plate Holdfast Stem of High grade copper Alloy Required for installation of tape/Strip is to be secured away from the face of wall/ceiling with appropriate D.C Clip. Make As per GE recommendation | 10 | each | ageusec | 15 |
| 7 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment PVC covered Soft Drawn Copper Conductor of size 150 Sqmm with composition 37/2.25 ( No of Strand/Wire Dia mm) Make As per GE recommendation | 20 | rm | ageusec | 15 |
| 8 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment Back Plate Holdfast Stem of High grade copper Alloy Required for installation of tape/Strip is to be secured away from the face of wall/ceiling with appropriate D.C Clip. Make As per GE recommendation | 5 | each | ageusec | 15 |
| 9 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment Bi-metallic Connector Tape/Strip To Conductor of size 25x3 with 150 Sqmm of High grade copper alloy connectors are used in bi-metallic earthing systems to use inhibiting compound with this assembly. Make As per GE recommendation | 2 | each | ageusec | 15 |
| 10 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment Square Tape /Strip Clamp of High Grade Copper Alloy Suitable for 4 way connections, straight through or tee joints for tapesof size 25x3 mm. Make As per GE recommendation | 2 | each | ageusec | 15 |
| 11 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment D.C Tape/Strip Clip with base of high grade copper alloy Used for Supporting & Secure Flat tape to the structure of size 25x3 mm. Make As per GE recommendation | 2 | each | ageusec | 15 |
| 12 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/ replacment Air Terminal Base of High Grade Copper Alloy Ridge Saddle used for supporting lightning conductor air terminals on the roof ridges. For supporting air rods onto flat roof surfaces and to accommodate conductor tape/Strip for lightning protection system of 12 mm dia rod & 25 x3 mm tape size. Make As per GE recommendation | 1 | each | ageusec | 15 |
| 13 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | M&L in repair/ replacment for Earth Enhancing Back Fill chemical Compound (Bentonite) to additional filling in the chemical Earthing complete all as specified and directed Make As per GE recommendation | 135 | kg | ageusec | 15 |
| 14 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair /replacment of old unsv light with Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting of capacity 180 watt complete all asspecified and directed. Make As per GE recommendation | 12 | each | ageusec | 15 |
| 15 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair /replacement of old unsv light with Solar Street Light of capacity 40 watt is made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, which increases the backup time. Make As per GE recommendation | 10 | each | ageusec | 15 |
| 16 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | S&F in repair/replacment of old PCC pole with Decorative Casting poles in different designs, cylendrical shaped and heights of 6 meter to compliment the LED Post Top of dia not less than 76 mm complete all as specified and directed. Make As per GE recommendation | 10 | each | ageusec | 15 |
| 17 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | Supply and fixing in replacement of 150 mm dia DI rising Spindle Resilient seated Gate Valve PN 16 (Soft Sealed) soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or equivalent grade as per IS 3896- Part - 2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quiality and Seals of NBR and the valve should be vacum tight and 100 % leak proof with face to face dimention as per BS 5163-89/IS 14846-2000/DIN 3202 F4 and Valves should be electrostatic powder coating both inside and outside pocket less body passage.including all jointing materials (Gasket, Nutbolts ets) connecting , testing and taking down old unservicable sluice valve complete all as specified and directed Make As per GE recommendation | 2 | each | ageusec | 15 |
| 18 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | Supply and fixing in replacement of 200 mm dia DI rising Spindle Resilient seated Gate Valve PN 16 (Soft Sealed) soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or equivalent grade as per IS 3896- Part - 2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quiality and Seals of NBR and the valve should be vacum tight and 100 % leak proof with face to face dimention as per BS 5163-89/IS 14846-2000/DIN 3202 F4 and Valves should be electrostatic powder coating bot inside and outside pocket less body passage.including all jointing materials (Gasket, Nutbolts ets) connecting , testing and taking down old unservicable sluice valve complete all as specified and directed Make As per GE recommendation | 2 | each | ageusec | 15 |
| 19 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | Supply, fabrication, and installation in repair /replacment of retro-reflective glow sign board for MES office/work, comprising a double-sided sign board of 2 mm thick aluminium composite panel (ACP) with 2 mm aluminium skin, size 2000 mm x 1500 mm. Includes high-intensity prismatic (HIP).... AS PER SoW | 2 | each | ageusec | 15 |
| 20 | MISC REPAIR MAINTAINCE OF ELECTRIC AND WATER SUPPLY INSTALLATION IMRPOVEMENT OF EARTHING INFRA FLOOD LIGHTING IN AREA UNDER AGE EM I OF GE U SECUNDERABAD | Supply, fabrication, and installation in repair /replacment of retro-reflective glow sign board for MES office/work, comprising a double-sided sign board of 2 mm thick aluminium composite panel (ACP) with 2 mm aluminium skin, size 1600 mm x 900 mm. Includes high-intensity prismatic (HIP).... AS PER SoW | 2 | each | ageusec | 15 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | KIRAN ASSOCIATES Under PMA | - | 11-08-2025 13:00:30 | Disqualified |
| 2 | MAVEE SYNDICATE Under PMA | - | 10-08-2025 16:21:26 | Qualified |
| 3 | NINDI BUILDERS Under PMA | - | 11-08-2025 18:18:14 | Disqualified |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | MAVEE SYNDICATE(MSE,MII)( MSE Social Category:OBC ) Under PMA | ₹42,23,400 | Item Categories : MISC REPAIR MAINTAINCE OF ELECTRIC,MISC REPAIR MAINTAINCE OF WATER SUPPLY INSTALLATION,INSTALLATION |
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS