TenderDekho Logo
Closed GEM

Bids are Invited For Echo Cardiography Scanning Machine (V2) in GUNTUR, ANDHRA PRADESH

Bid Publish Date

04-Aug-2026, 12:27 pm

Bid End Date

26-Aug-2026, 1:00 pm

EMD

₹5,00,000

Progress

Issue04-Aug-2026, 12:27 pm
AwardPending

A tender has been published for All India Institute Of Medical Sciences (aiims) Echo Cardiography Scanning Machine (V2) (Q2) in GUNTUR, ANDHRA PRADESH. Quantity: 1 by. Submission Deadline: 26-08-2026 13: 00: 00. Check eligibility and apply.

Authority & Contact

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

50% Lowest Priced Technically Qualified Bidders

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

Yes

MII Preference Band

L1+20%

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

125

OEM Avg. Turnover

100

Warranty Period

3 days

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Echo Cardiography Scanning Machine (V2) (Q2)

Advisory Bank

State Bank of India

ePBG Percentage

3%

ePBG Duration (Months)

62

Pre-Bid & Qualification

Pre-Bid Date

14-08-2026 18:00:00

Pre-Bid Venue

Room No.2151,Conference Hall, Procurement Cell, Opposite to Mortuary Building, AIIMS Mangalagiri, Andhra Pradesh-522503

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9676600.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Categories 3

Required Documents

1

Experience Criteria

2

Bidder Turnover

3

Certificate (Requested in ATC)

4

OEM Authorization Certificate

5

OEM Annual Turnover

6

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

7

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Types of Probes & Features Cardiac and Vascular Probes Configuration TTE Phased Array, TTE Matrix Array, TEE Phased Array, TEE Matrix Array, Linear Probe
Types of Probes & Features TTE(Transthoracic) Probe Type Adult, Pediatric, Neonatal
Types of Probes & Features TEE Adult Probe biplane and Multiplane frequency, in MHz 2 to 7.5 MHz (±2)
Types of Probes & Features TEE Pediatric Probe Required Yes
Types of Probes & Features TEE Pediatric Probe frequency, in MHz 3 to 8 MHz (±2)
Types of Probes & Features Linear Probe for linear/ vascular applications required Yes
Types of Probes & Features Adult/Pediatric Linear probe frequency in MHz 5 to 14 MHz (±2)
Types of Probes & Features No of Adult TTE Probes Required 1
Types of Probes & Features No of Pediatric TTE Probes Required 1
Types of Probes & Features No of Neonatal TTE Probes Required 1
Types of Probes & Features No of Adult TEE Probes Required 1
Types of Probes & Features No of Pediatric TEE Probes Required 1
Types of Probes & Features No of Pediatric 3D/4D TEE Probes Required 1
Types of Probes & Features No of Neonatal TEE Probes Required 1
Types of Probes & Features No of Adult/pediatric Linear Probes supplied 1
Types of Probes & Features Dedicated 3D/4D volume imaging for cardiology TTE ad TEE Yes
Types of Probes & Features Live 3 D imaging in color doppler system Yes
Types of Probes & Features Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval Yes
Types of Probes & Features Provision of Tissue Colorization (B-Colour) for improved contrast resolution Yes
Types of Probes & Features Application software Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications
Types of Probes & Features Cine Loop Features Yes
Types of Probes & Features Frame grabber facility for post analysis Yes
Types of Probes & Features Facility of Various maps for pre and post processing Yes
Types of Probes & Features ECG trigger facility Yes
Types of Probes & Features User defined Preset Yes
Types of Probes & Features Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography Yes
Types of Probes & Features Number of transducer/probe ports 4
Scan Modes and Performance Parameters Cardiac 3-D freehand Option Yes
Scan Modes and Performance Parameters Cardiac 3D/4D automatic Option Yes
Scan Modes and Performance Parameters Contrast Harmonic/Agent Imaging with angio mode Yes
Scan Modes and Performance Parameters Color Doppler 3-D/4-D option Yes
Scan Modes and Performance Parameters Power Dopple 3-D/4-D option Yes
Scan Modes and Performance Parameters Contrast-enhanced ultrasound (CEUS) option Yes
Scan Modes and Performance Parameters Tissue synchronization, tissue velocity Yes
Scan Modes and Performance Parameters Cardiac Shear wave elastography No
Scan Modes and Performance Parameters Cardiac compression elastography No
Scan Modes and Performance Parameters Provision for higher sensitivity for low frequency doppler in all probes Yes
Scan Modes and Performance Parameters Latest generation Electronic Phased/sector array Colour Doppler system Yes
Scan Modes and Performance Parameters Number of Channels in color doppler system 5000000 or more (if channels are being designated as digital channels)
Scan Modes and Performance Parameters System should be capable of generating real time live 3- D images Yes
Image display and processing DICOM 3 Compliant Yes
Image display and processing Automated B-mode (2-D) image Yes
Image display and processing Automated CDI image optimization Yes
Image display and processing Automated PW Doppler image optimization Yes
Image display and processing Touch Screen Yes
Image display and processing Monitor display size, cm (in) 21 Inch(±1) Or higher
Image display and processing Split screen Twin View
Image display and processing Single/dual monitors Dual (image display on touch panel)
Image display and processing Speckle-tracking strain and strain rate Yes
Image display and processing Analysis and calculation packages 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No
Image display and processing Type of printer provided with the echo cardio machine Themal Printer
Image display and processing Type of processor in PC i7 or Latest
Image display and processing Conectivity between Echo cardiogram and PC Through IMS/Equivalent Software
Image display and processing PC with all software inclusive interfaced with echocardiograph machine Yes
Image display and processing Inkjet printer provided with computer for reporting Yes
Image display and processing Glossy Colour Print Paper supplied Not provided
Image display and processing ECG Cable 2
Image display and processing Echo cardiography sytem to be DICOM Ready Yes
Image display and processing Dicom Interfacability to HIS Yes
Image display and processing Dicom Interfacability Dicom to PACS Yes
Image display and processing Interfacability Dicom to RIS Yes