TenderDekho Logo
Active GEM

Bids are Invited For Porta Cabin (Cement Fiber Board) in NORTH DELHI, DELHI

Bid Publish Date

21-Aug-2026, 5:32 pm

Bid End Date

11-Sep-2026, 6:00 pm

EMD

₹11,000

Value

₹5,50,000

Location

NORTH DELHI , DELHI

Progress

Issue21-Aug-2026, 5:32 pm
AwardPending

N/a announces a tender for Porta Cabin (Cement Fiber Board) (Q3) in NORTH DELHI, DELHI. Quantity: 1. Submission Deadline: 11-09-2026 18: 00: 00. Last date to apply is approaching fast!

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

180 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

Tech Clarification Time

2 Days

Preference & Exemptions

EMD Required

Yes

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

Bid Splitting Applied

No

Requirements

Min. Avg. Annual Turnover

2

OEM Avg. Turnover

15

Past Performance

50 %

Experience Required

3 Year (s)

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Porta Cabin (Cement Fiber Board) (Q3)

Advisory Bank

State Bank of India

ePBG Percentage

5%

ePBG Duration (Months)

14

Payment Timelines

Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)

Delivery Details

Max Delivery Days

90

Delivery Locations

1

Delivery Cities

North

Delivery Pincodes

110042

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Bimal Jain110042,DELHI TECHNOLOGICAL UNIVERSITY Shahbad Daulatpur, Main Bawana Road, Rohini Delhi- 110042. IndiaNorthDelhi110042190-

Authority Records

TRAINING AND TECHNICAL EDUCATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 3

GeM-Bidding-9771450.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Authority & Contact

Organization

N/a

Office Name

North West Zone

Grievance Contact

[email protected]

Categories 3

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERIC Configuration of Cabin With one Room only.
GENERIC Approval of Advance sample No Advance Sample
GENERIC Time period for completion of Erection work at site by seller Within 30 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work
GENERIC Suitability / structural stability / completness of structures, the structure is intended for use in In wind condition of 55m/s - in Seismic zone V and ambient temperature range (-) 40 degree C to (+) 50 degree C - 1 M snow load standing on the roof - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition.
GENERIC Shape of Cabin Square
GENERIC Ventilation 1 no. 255 mm x 255 mm exhaust Fan to be fixed on side wall.
GENERIC Storage provision N.A
GENERIC Provision for Power Connection Provision for Power Connection not required.
GENERIC Provision for Cable , Switches and Junction box connection Seller to make appropriate provisions for cable laying - installing meter / junction box with switches - other related electrical accessories as may be require for the power supply to the Cabin.
GENERIC Other requirements All necessary required permissions from civic agencies for installation and commissioning to be arranged by seller - necessary assistance / documents required to be provided by Buyer.
GENERIC To obtain power connection for Cabins N.A
GENERIC Electricity charges N.A
PANEL MATERIAL Side wall panel material Internal face of wall of 8 mm thick and external face of wall of 9 mm heavy duty fire and water proof of cement fiber board with 30 mm high density thermocal sandwich between Internal and external walls.
PANEL MATERIAL Door panel material Flush door 32 mm thick water proof.
PANEL MATERIAL Window panel material Powder coated aluminium sliding windows with 4 mm tinted Glass
PANEL MATERIAL Door and Window canopy material 18 gauge MS corrugated sheet.
PANEL MATERIAL Floor panels material 19 mm thick marine grade plywood confmg. to IS 710 / latest to be laid on top and secured by self - tapping screws to the base members - Covered with 2 mm thick PVC sheets.
PANEL MATERIAL Roof panel material Insulated Roof to be made of continue line sandwich panels with 0.35 mm thick pre-coated steel sheet (PPGI sheet) having 120GSM with minimum 4 microns epoxy primer on both sides of sheet and polyester top coat minimum 15 microns ON BOTH SIDES OF PUF.
PANEL MATERIAL Insulation material for sides and End walls 30 mm high density thermocol.
PANEL MATERIAL Insulation material for Roof With polyurethane foam (PUF) having density 40 Kg/CuM ± 2 Kg / CuM
PANEL MATERIAL Inside panel material for sides, end walls & roof Consists of 8 mm thick pre-laminated board.
FRAME MATERIAL Roof frame Made of MS having stiffner Top 50 mm x 25 mm x 2.5 mm thick and 32 mm x 32 mm x 2 mm MS sq. tubes
FRAME MATERIAL Side Panel frame Made of MS having stiffner Top 40 mm x 20 mm x 4 mm thick
FRAME MATERIAL Floor panel frame MS having 50 mm x 50 mm x 1.2 mm
FRAME MATERIAL Door panel frame Made of aluminium powder coated frame.
Dimensions and Thickness Inside Length ± 15 mm 1830 mm
Dimensions and Thickness Inside Width ± 15 mm 1220 mm
Dimensions and Thickness Total Height (mm) ± 15mm 2135 mm
Dimensions and Thickness Size of Window ± 10 mm 760 mm x 915 mm
Dimensions and Thickness Size of door hinges 100 mm of SS 304
Dimensions and Thickness Size of Door / Window Chajja (projection if any) ± 10 mm 455 mm wide 45 degree slope
Dimensions and Thickness Roof projection (if any) ± 10 mm 305 mm to be given on all sides at full height of cabins.
Dimensions and Thickness Total thickness of Wall panel ± 2 mm 40 mm
Dimensions and Thickness Total thickness of Door panel ± 2 mm 35 mm
Dimensions and Thickness Roof ridge height ± 10 mm Total height (i.e. height of side panels) + 760 mm
Dimensions and Thickness Almirah / Cabinet size ± 5 mm N.A
Dimensions and Thickness Verandah size N.A
MISCELENIOUS Number of Door hinges 2 nos.
MISCELENIOUS safety Grills (for windows) N.A
MISCELENIOUS Door to be provided On one of the longer side
MISCELENIOUS Electric fittings Only electric points to be provided for one fan - One light - One bulkhead fitting point - one 5 amp. power point with Switch board including Double pole MCB 20A with metal enclosure - continuous earth wires to be provided and also external earth terminal to be provided.
MISCELENIOUS Number of Doors 1
MISCELENIOUS Number of Windows 1 no. window
MISCELENIOUS Doors (against water ingress in closed condition) To be sealed by using rubber gasket profiles.
MISCELENIOUS Roof slope 1 : 4 (approx) Self Draining Type
MISCELENIOUS Door opening External
MISCELENIOUS Roof ridge To be made out from 0.45 mm thick PPGI sheet.
MISCELENIOUS Flashing item (U track, L corner etc) To be made out with 0.45 mm thick PPGI sheet in require size and shape.
MISCELENIOUS Locking / Security Cabin have to be provision of locking Door and Windows to prevent unwanted intrusion and theft.
MISCELENIOUS Overall covered area by Roof ± 10 mm 1830 mm x 2440 mm
COLOUR & FINISH Colour As per Buyer's choice
COLOUR & FINISH Top coat Chlorinated rubber paint 50 microns.
COLOUR & FINISH Paint outside All exterior panels to be white and Blue texture excluding the acrylic / polycarbonate and aluminium frames.
COLOUR & FINISH Inside finish Internal panels - doors - ceiling - shutter to be white finish (excluding polycarbonate / acrylic glass sheet and aluminium frames on windows)
COLOUR & FINISH Logo (if any) No logo
WARRANTY Service Maintenance N.A
WARRANTY Warranty 1 - Year
CERTIFICATION OEM of offered product is ISO 9001:2015 certified No
CERTIFICATION OEM of offered product is ISO 14001:2015 certified No
CERTIFICATION OEM of offered product is ISO 18001:2007 certified No

Explore More Opportunities

Quick Access