Technical Specifications
1 Item
Item #1 Details
View Catalog| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE PARAMETERS | Patient Type | Neonatal |
| PERFORMANCE PARAMETERS | Tidal Volume Range In ml | 2 to 300 |
| PERFORMANCE PARAMETERS | Trigger Sensitivity Mechanism | Pressure, Flow, Pressure and Flow |
| PERFORMANCE PARAMETERS | Flow Pattern/Waveform Adjustment | Yes |
| PERFORMANCE PARAMETERS | Sigh Breath Function | Yes |
| PERFORMANCE PARAMETERS | Leak Compensation Available | Yes, No |
| PERFORMANCE PARAMETERS | Auto 100% increase O2 Button | Yes |
| PERFORMANCE PARAMETERS | Inspiratory Pause Available | Yes |
| PERFORMANCE PARAMETERS | Expiratory Hold Available | Yes |
| PERFORMANCE PARAMETERS | Suction Control Option Available | Yes, No |
| PERFORMANCE PARAMETERS | Nasal CPAP Option Available | Yes, No |
| PERFORMANCE PARAMETERS | Auto PEEP Manoeuvre | Yes, No |
| PERFORMANCE PARAMETERS | Control Panel Lock | Yes, No |
| PERFORMANCE PARAMETERS | Facility for double lung ventilation | Yes, No |
| PERFORMANCE PARAMETERS | Integrated Air Compressor | Yes |
| VENTILATION MODES | PSV(Pressure supported ventilation) | Yes |
| VENTILATION MODES | P-CMV(Inspiration pressure control) | Yes |
| VENTILATION MODES | PC-AC With Expiratory Minimal volume | Yes, No |
| VENTILATION MODES | SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV | Yes |
| VENTILATION MODES | ITT - Inspiratory Time Termination | Yes, No |
| VENTILATION MODES | CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation | Yes |
| VENTILATION MODES | High Frequency Oscillation Ventilator(HFOV) | Yes |
| PATIENT ASSESSMENT TOOLS | Capnography/Co2 Monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | Volume Guarantee | Yes |
| PATIENT ASSESSMENT TOOLS | APRV | Yes, No |
| PATIENT ASSESSMENT TOOLS | Oxygen Therapy | Yes, No |
| ADDITIONAL CAPABILITIES | ETCO2 Inbuilt available | Yes, No |
| HUMIDIFIER | Disposable Neonatal breathing circuit (dual heated wire) | 20, 50, 80, 100, NA |
| HUMIDIFIER | Auto Feed Humidification chamber Available | Yes |
| HUMIDIFIER | Disposable Neonatal breathing circuit with single heated wire provided for inspiratory Limb with Water trap in expiratory limb available | 20, 50, 80, 100, NA |
| ADDITIONAL PARAMETERS | Output Ports Type | HDMI, Ethernet, RJ 45, USB |
| ADDITIONAL PARAMETERS | Remote Alarm Display Port | Yes, No |
| ADDITIONAL PARAMETERS | Reporting (Vent alarms and Patient Status) | Yes, No |
| ADDITIONAL PARAMETERS | View Reports on Display | Yes, No |
| ADDITIONAL PARAMETERS | Save Data to USB | Yes, No |
| ADDITIONAL PARAMETERS | Send Data Via Network | Yes, No |
| ADDITIONAL PARAMETERS | Display Type | LCD/LED/TFT |
| ADDITIONAL PARAMETERS | Display Size in Inches | ≥ 10, ≥ 12, ≥ 15 Or higher |
| ADDITIONAL PARAMETERS | Can be used For Patient Transport | Yes, No |
| ACCESSORIES | Nasal CPAP Kit | 10 |
| ACCESSORIES | Number of Disposable flow sensor | 20, 50, 100, NA if Reusable |
| ACCESSORIES | Number of Reusable flow sensor | 3, 6, NA if Disposable |
| ACCESSORIES | Trolley with ventillator with supporting arm from same manufacturer | Yes, No |
| ACCESSORIES | Autoclavable exhalation valve/expiratory cassette | 2, 3 |
| ACCESSORIES | Test Lung Available | Yes |
| POWER REQUIREMENTS | Operating time of battery in min | 30 |
AI-Powered Bidder Prediction
Companies most likely to bid
Unlock Bidder Insights
AI predictions on likely bidders
Required Documents
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Similar Tenders
Neonatal Ventilators
Medical Education Department Uttar Pradesh
AGRA, UTTAR PRADESH
Neonatal Ventilators
Health & Family Welfare Department Gujarat
,
Neonatal Ventilators
Medical Education Department Uttar Pradesh
JAUNPUR, UTTAR PRADESH
Neonatal Ventilators
Medical Education Department Uttar Pradesh
AGRA, UTTAR PRADESH
Download FREE!
Access all tender documents at no cost
Documents 3
GeM-Bidding-8287278.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS
GeM-Bidding-8287278.pdf
Main Document
CATALOG-Specification-1
CATALOG Specification
GEM General Terms and Conditions Document
GEM_GENERAL_TERMS_AND_CONDITIONS