Organization: Skuastkashmir, a government agricultural science university procurement for a Gas Chromatograph – Triple Quadrupole Mass Spectrometer (GC-MS-MS, Q3) system. Estimated value: ₹12,500,000 with an EMD ₹250,000. Location: Kashmir region; scope includes a fully integrated GC-MS-MS platform with multiple detectors and accessories. Key differentiators include broad detector suite, headspace and pyrolysis compatibility, and on-site training. This tender emphasizes compliance with safety and laboratory standards and turnkey installation.
GC Detectors inclusive in the scope of supply
Number of FID/TCD/ECD/NPD/FPD/PID/PFPD detectors inclusive
Inlet/Detector ports supporting simultaneous operation
Capillary columns included and type specified; GC capillary length
GC Oven max operating temperature and programmable ramps
Mass Spectrometer: ionization modes and detector type; SRM/MRM sensitivity
Software, libraries, and compatibility with desktop workstation
PESO-certified gas cylinders, regulators, gas supply included
Option clause allows quantity variation up to 25% with contracted rates
Delivery period extension governed by last delivery date; minimum 30 days
Warranty, onsite training days, spares availability, and AMC terms to be included
EMD ₹250,000; payment terms to be specified in contract per supplier and project schedule
Option to increase quantity up to 25% and corresponding delivery extension; minimum 30 days extension if exercised
LDs to be defined; ensure compliance with installation, commissioning deadlines and performance milestones
Experience in supplying GC-MS-MS systems to government or research institutions
Proven NABL/ILAC-accredited test reports or equivalent certifications
OEM authorization for GC-MS-MS platform and accessories
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
National Institute Of Pharmaceutical Education And Research (niper) Kolkata
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)
PONDICHERRY, PUDUCHERRY
N/a
SRINAGAR, JAMMU & KASHMIR
Directorate Of Forensic Science Services (dfss)
JAMMU, JAMMU & KASHMIR
Ap Forensic Science Laboratory
GUNTUR, ANDHRA PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | GC Detectors inclusive in the scope of supply | Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD or Hot Wire Detector), Electron Capture Detector (ECD), Nitrogen–Phosphorus Detector (NPD) / Flame Thermionic Detector (FTD), Flame Photometric Detector (FPD), Photo Ionization Detector (PID), Pulsed Flame Photometric Detector (PFPD) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 1, 2, 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 1, 2, 3, 4 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | Polar, Non-Polar, Semi-Polar, NA |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length | 0, 30, 60, 100 |
| PERFORMANCE | "GC Detector Minimum Detection Level (MDL) | < 1.4 pg C/s for FID, < 1.8 pg C/s for FID, < 3.0 pg C/s for FID < 400 pg/ml for TCD, < = 1 microgram/ml for TCD, < = 10 microgram/ml for TCD, < 4.5 fg /sec for ECD, < 5.5 fg /sec for ECD, < 0.1pg N /sec for NPD/FTD, < 0.03 pg P /sec for NPD/FTD, < 100 fg P /sec for FPD, <2.5 pg S /sec for FPD, <5 pg S /sec for FPD, < 45 fg P /sec for FPD |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 400 deg. C, upto 450 deg. C Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 6/7 or more, 9/10 or more, 20/21 or more |
| PNEUMATIC CONTROL | Number of Injection Ports | 1, 2 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 400 deg. C, upto 450 deg. C Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto100 psi, upto 140 psi Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001, 0.01, 0.1 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | Split, Splitless, split / Splitless, Programmable Temperature Vaporizer (PTV) |
| PNEUMATIC CONTROL | Split Ratio | 6000:1, 7000:1, 7500:1, NA |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | Yes, No |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 0, 8, 100, 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 0, 1, 2 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0, 2 |
| AUTO INJECTOR / AUTO SAMPLER | "Liquid Auto Sampler Features (Select applicable features Only)" | Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply), NA |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | Yes, No |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | 12 or better, NA |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | Upto 200 deg. C or better, NA |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | Yes, No |
| MASS SPECTROPHOTOMETER (MS-MS) SYSTEM | Ionization modes | Electron Ionization (EI), EI/PCI/NCI |
| MASS SPECTROPHOTOMETER (MS-MS) SYSTEM | Detector Type | Electron Multiplier, Triple-Axis, HED-EM |
| MASS SPECTROPHOTOMETER (MS-MS) SYSTEM | Operating modes | Full Scan Mode, Selective Ion Monitoring (SIM) Mode, Both Full Scan & SIM Modes, Selective /Multiple Reaction Monitoring (SRM/MRM) |
| PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS-MS) SYSTEM | Sensitivity (S/N Ratio) in full scan | 300:1, 1500:1 Or higher |
| PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS-MS) SYSTEM | Sensitivity (S/N Ratio) in SRM/MRM | 6000:1, 15000:1, 30000:1 Or higher |
| GENERIC | Power Supply | 230 V ± 10%, 415 V ± 10% |
| GENERIC | Built-in Display | Yes, No |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | Yes, No |
| GENERIC | Back Flash - inclusive in the scope of supply | Pre Column Back Flush, Post Column Back Flash, Mid Column Back Flash, NA |
| SALIENT FEATURES OF GC-MS-MS | "Salient Featutes of GC-MS (Select applicable features Only)" | Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Flow sensor for control & storage of split ratio, Split and Septum Purge gases, Able to direct inject onto packed and wide-bore capillary columns, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Display Unit with built-in Key Board, Controlled by External PC System, Programmable ion source temperature, System includes variety of auto tune algorithms to tune the instrument for maximum sensitivity or for specific target compounds, EI source is inert to active compounds and programmable, EI Source have a dual filament design with automatic selection of other filament if one fails during analysis;, NA, Off-axis detection system for better removal of neutrals, Electron Impact ion source with dual filaments temperature up to 350 °C, Emission current should be able to set up to 300 µA or better, MRM/SRM Transitions should be 800 transitions/sec, Buyer specific columns - DB-fame /equivalent column 60 m x 0.25 mm id x 0.25 micron- 2 nos , DB-1 /equivalent column 60 m x 0.25 mm id x 0.25 micron- 1 nos, Instrument detection limit sensitivity of < 2 fg during installation using 5 fg of OFN with 1 ul injection with Auto sampler |
| LIBERARIES | Libraries for GC-MS | NIST Library for MS - Licensed version - 2017 or latest, MRM data base Library, Library for Pesticides, Library for Environmental, Library for Forensic, Wiley Library, NA |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Chromatographic attributes, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices |
| ACCESSORIES | Gas Supply inclusive in the scope of supply | Nitrogen, Hydrogen, Argon, Helium, Zero Air, Not offered |
| ACCESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 0, 1, 2 |
| ACCESSORIES | Gas cylinders certified by PESO | Yes, NA for Gas Cylinder not offered |
| ACCESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator, NA |
| ACCESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Syringe for manual injection x 05 nos, Auto Sampler Vials x 1000 vials with screw cap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Column Cutter x 2 nos, Gas tube Cutter x 2 nos, Tool Kit x 1 no., User / Technical / Maintenance Manual, Standard Samples - NIST / IPL Traceable, Direct Injection Port, Splitter, Multishot Pyrolyser, Singleshot Pyrolyser, Syringe for Auto Sampler injection x 10 nos, EI filaments x 5 nos, NA |
| DESKTOP WORKSTATION | Desktop workstation Suitable to GC-MS - inclusive in the scope of supply | Yes, No |
| DESKTOP WORKSTATION | Graphics Card Memory Size | 0, 1, 2, 4 |
| ONLINE UPS | UPS Provided in the Scope of Supply | Yes, No |
| ONLINE UPS | Rating of online UPS(KVA) | 5.0 KVA, 7.5 KVA, 10 KVA, NA |
| ONLINE UPS | Backup time of online UPS | 0, 60, 90, 120 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 1, 2, 3, 5 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 3, 5, 7, 10 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per EN 61010- 1:2010 Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | Yes, No |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes, No |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | Yes, No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Key insights about JAMMU AND KASHMIR tender market
Bidders must submit EMD ₹250,000, GST and PAN, experience certificates, financial statements, OEM authorization, and technical bid documents. The GC-MS-MS platform requires IS 61010 safety, EN 61326 EMI compliance, and NABL/ILAC test reports. Ensure on-site training and spares availability are included in the proposal.
Required documents include GST registration, PAN, company profile, financial statements for last 3 years, EMD payment receipt, technical compliance certificates, OEM authorization letters, installation and commissioning plan, and warranty/AMC terms. NABL/ILAC lab test reports should accompany testing specifications.
Equipment must meet IS 61010 safety requirements, EN 61326-1 EMC; CE marking where applicable; NABL/ILAC-certified test reports for conformity; software libraries compatible with GC-MS systems; PESO gas cylinders with regulators included.
The EMD is ₹250,000. Submit via online payment or demand draft as per bid terms. Ensure EMD documents are attached with the technical bid and clearly indicate bid security validity through the evaluation period.
Delivery terms allow up to 25% quantity variation; extended delivery period possible with a minimum 30-day increase; final installation and commissioning occur after delivery with onsite training and warranty activation included in the package.
Eligibility requires prior experience with GC-MS-MS platform deployments, OEM authorization, NABL/ILAC testing evidence, financial strength, and compliance with IS 61010 and EMC standards. Bidders must provide installation capabilities and post-sale support plans.
Auto sampler must be compatible with liquid samples, offer multiple vial capacities, multiple injection ports and channels; headspace sampler capacity expected with carousel options; both should integrate with GC-MS-MS control software and offer reliable sample throughput.
The package should include onsite training days, comprehensive warranty coverage for main equipment and spares, and guaranteed availability of spare parts. Training duration and post-installation support terms must be specified in the contract.