Organization: Indian Council Of Agricultural Research (ICAR) under the Department Of Agricultural Research And Education (DARE). The procurement concerns a complete Gas Chromatograph (GC) configuration package including detectors, autosampler integration, headspace compatibility, and ancillary accessories. EMD ₹150,000 is required; supplier must meet OEM and compliance standards. The scope emphasizes detector inclusions, multiple detector options, and simultaneous detector/column configurations. The project is location-agnostic in this excerpt, with a focus on scrupulous GC system specification and service support. The tender stresses flexible delivery and option clauses for quantity adjustments up to 25%, and requires adherence to established safety and quality norms. Unique aspects include integration of a wide range of detectors, compatibility with liquid auto samplers, head space samplers, pyrolyzers, and mandatory testing certifications. This opportunity targets suppliers of high-complex GC configurations for agricultural research applications managed by ICAR.
GC configuration with detectors included in scope
Detectors presence indicators per detector type (FID, TCD, ECD, NPD/FTD, FPD, PID, PFPD) with 0/available values
Capillary column count and type; column length where applicable
Inlet/port counts and simultaneous detector support
MDL (minimum detection level) for detectors
GC oven max temperature and ramp rate
Pneumatic control: injection ports, heating max, pressure range
Liquid Auto Sampler: vial capacity, injection ports, channels, min/max volumes
Head Space Sampler: carousel capacity and temperature range
Pyrolyzer compatibility and integration
Software features and data connectivity
Gas supply and cylinder details; regulator inclusions
Environmental operating ranges; humidity tolerance
Certification/Test Reports: UL/CE, EMC/EMI, NABL/ILAC
EMD amount and submission method with required bank details
Delivery time and extension rules under option clause (up to 25%)
OEM authorization and after-sales support requirements for imported items
GST handling and eligibility criteria including financial standing
Documentation and conformity certificates required for bid submission
Warranty, onsite training, and availability of spares
GST payable by bidder; EMD/DD submission; payment as per contract terms; hard copy delivery within 5 days
Delivery period may be extended by option-quantity calculation; minimum 30 days extension; delivery begins after order date
LDs to be specified per contract for late delivery or non-conformance; ensure compliance with NABL/ILAC test reports
OEM with positive net worth as per last audited statement
Experience in supplying GC configurations with detectors and accessories
Registered in India with after-sales support capability for imported items
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Gas Chromatography (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
14
Max Delivery Days
120
Delivery Locations
1
Delivery Cities
East Godavari
Delivery Pincodes
533105
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Adimoolam Veera Venkata Ramana | 533105,ICAR-CENTRAL TOBACCO RESEARCH INSTITUTE, BHASKAR NAGAR, RAJAHMUNDRY | East Godavari | Andhra Pradesh | 533105 | 1 | 120 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
OTHER
OTHER
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" | Flame Ionization Detector (FID), Electron Capture Detector (ECD), Nitrogen–Phosphorus Detector (NPD) / Flame Thermionic Detector (FTD) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 1, 2, 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 1, 2, 3, 4 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | Polar, Non-Polar, Semi-Polar, NA |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 0, 30, 60, 100 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" | 0, 1, 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Length (Hint:-Select '0' if Not Applicable)" | 0, 3, 6, 9, 12 |
| PERFORMANCE | "GC Detector Minimum Detection Level (MDL) " | < 1.4 pg C/s for FID, < 1.8 pg C/s for FID, < 3.0 pg C/s for FID < 400 pg/ml for TCD, < = 1 microgram/ml for TCD, < = 10 microgram/ml for TCD, < 4.5 fg /sec for ECD, < 5.5 fg /sec for ECD, <= 100 fg/sec for ECD, < 0.1pg N /sec for NPD/FTD, < 0.03 pg P /sec for NPD/FTD, <0.5 pg P/s for NPD/FTD, < 45 fg P /sec for FPD, < 100 fg P /sec for FPD, <2.5 pg S /sec for FPD, <2.5 pg S /sec for FPD, <5 pg S /sec for FPD, <10pg S/s for FPD |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 400 deg. C, upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 6/7 or more, 9/10 or more, 20/21 or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature Ramp Rate - Maximum | 120 Deg. C/minute or better, 50 Deg. C/minute or better |
| PNEUMATIC CONTROL | Number of Injection Ports | 1, 2 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 400 deg. C (1), upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto100 psi (1), upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001, 0.01, 0.1 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | Split, Splitless, split / Splitless, Purged packed Inlet |
| PNEUMATIC CONTROL | Split Ratio | 6000:1, 7000:1, 7500:1, NA |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | Yes, No |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 0, 15, 100, 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 0, 1, 2 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0, 2 |
| AUTO INJECTOR / AUTO SAMPLER | Minimum Volume of the injected liquid sample | 0 - 1 |
| AUTO INJECTOR / AUTO SAMPLER | Maximum Volume of the injected liquid sample | 0 - 100 |
| AUTO INJECTOR / AUTO SAMPLER | "Liquid Auto Sampler Features (Select applicable features Only)" | Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply), NA |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | Yes, No |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | 12 or better, NA |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | Upto 200 deg. C or better, NA |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | Yes, No |
| SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) | "Salient Featutes of GC (Select applicable features Only)" | Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Flow sensor for control & storage of split ratio, Split and Septum Purge gases, Able to direct inject onto packed and wide-bore capillary columns, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Display Unit with built-in Key Board, Controlled by External PC System, NA |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Chromatographic attributes, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices |
| GENERIC | Display | Through PC (PC is not part of supply), Built-in Display |
| GENERIC | Connectivity interface | USB, WIFI, ETHERNET, Bluetooth, RS 232, RJ-45 |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | Yes, No |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Nitrogen, Hydrogen, Argon, Helium, Zero Air, Not offered |
| ACESSORIES | Capacity of Gas cylinder | 47 liters water capacity, Not offered |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 0, 1, 2 |
| ACESSORIES | Gas cylinders certified by PESO | Yes, No for Gas Cylinder Not Offered |
| ACESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator, NA |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Syringe for manual injection x 05 nos, Auto Sampler Vials x 1000 vials with screw cap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Column Cutter x 2 nos, Gas tube Cutter x 2 nos, Tool Kit x 1 no., User / Technical / Maintenance Manual, Standard Samples - NIST / IPL Traceable, NA |
| ENVIRONMENTAL | Minimum Operating Temperature | 0 - 10 |
| ENVIRONMENTAL | Maximum Operating Temperature | 30 - 65 |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | Up to 95 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 1, 2, 3, 5 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 3, 5, 7, 10 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | Yes, No |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use | Yes, No |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | Yes, No |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card
Experience certificates for GC/system integration projects
Financial statements / net worth confirmation
EMD proof (DD or online payment receipt)
Technical bid documents showing GC configuration capabilities
OEM authorization / distributor confirmation
Product conformity certificates (UL/CE), EMC/EMI test reports
NABL/ILAC accredited lab conformity reports
Bidders must submit GST, PAN, experience certificates, financials, and EMD ₹150,000 via DD to ICAR unit CTRI Rajahmundry. Include OEM authorization, technical compliance, and NABL/ILAC test reports. Ensure IS/IEC certifications and after-sales support. Delivery and option-clause terms apply; read purchaser terms carefully.
Required documents include GST certificate, PAN, bidder/organization experience certificates in GC systems, last 3 years financial statements, EMD proof, OEM authorization, technical compliance, and safety/test certificates (UL/CE and EMC per IEC standards). Ensure delivery and hard-copy submission within specified timelines.
GC configuration must include detectors within scope; specify FID/TCD/ECD/NPD/FPD/PID presence if supplied. Auto sampler compatibility with liquid samples, vial capacity, number of injection ports, and channels. Head space compatibility and pyrolyzer integration are required features where applicable.
EMD is ₹150,000; payment via account payee DD to ICAR unit CTRI Rajahmundry or online as per terms. GST handling remains bidder responsibility. After award, DD may substitute PBG; hard copy must reach within 15 days post-award if applicable.
Equipment must show UL/CE certificates per IEC 61010-1 for safety, EMC/EMI conformity per IEC 61326-1, and NABL/ILAC compliant test reports. Imported items must have Indian after-sales support with OEM authorization and registered Indian office for service.
Bid allows ±25% variation in quantity at contract placement, with extended delivery period calculated as (increased quantity/original quantity) × original delivery period, minimum 30 days. The extension applies to the quantity adjusted during contract execution.
Equipment carries standard warranty with onsite training days specified by the supplier. Training duration and availability of spares are part of the post-sale terms; ensure alignment with installation, commissioning support, and vendor service commitments as per contract.
Confirm detector inclusivity by itemizing which detectors are supplied, the number of capillary columns, column length/type, and inlets supported. Include MDL, oven max temperature, and ramp rates. Provide conformity certificates and test reports to satisfy IEC and NABL/ILAC standards.