Supply installation, testing and commission of Air Conditioner Cooling Capacity 2.0 Ton as per spec
West Central Railway
BHOPAL, MADHYA PRADESH
Bid Publish Date
17-Nov-2025, 10:41 am
Bid End Date
08-Dec-2025, 11:00 am
Location
Progress
RAQuantity
64
Category
Supply of air cooled floor mounted package air conditioner having cooling capacity Q -48 KW min air flow rate 11000 CMH min and pressure head 400 Pa min as per attached technical specification
Bid Type
Two Packet Bid
Nuclear Power Corporation Of India Limited invites bids for Supply of air cooled floor mounted package air conditioner having cooling capacity Q -48 KW min air flow rate 11000 CMH min and pressure head 400 Pa min as per attached technical specification, Supply of air cooled floor mounted package air conditioner having cooling capacity Q-24. 3 KW min air flow rate 4080 CMH min as per attached technical specification, Supply of air cooled floor mounted package air conditioner having cooling capacity Q-32 KW min air flow rate 7000 CMH min and pressure head 600 Pa min as per attached technical specification, Supply of air cooled floor mounted package air conditioner having cooling capacity Q- 10. 92 KW min air flow rate 6300 CMH min and pressure head 600 Pa min as per attached technical specification, Supply of air cooled floor mounted package air conditioner having cooling capacity Q-16 KW min air flow rate 4000 CMH min and pressure head 400 Pa min as per attached technical specification, Supply of air cooled floor mounted package air conditioner having cooling capacity Q-45 KW min air flow rate 9000 CMH min and pressure head 500 Pa min as per attached technical specification, Supply of ceiling mounted ductable IDU unit of cooling capacity 3 TR air cooled including additional 5 meter copper tube length liquid, Supply of Split system with suspended sub ceiling IDU of cooling capacity 4 TR min air cooled ODU unit including additional 5 meter copper tube length liquid in TIRUNELVELI, TAMIL NADU. Quantity: 64. Submission Deadline: 08-12-2025 11: 00: 00. Submit your proposal before the deadline.
Main Document
OTHER
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
West Central Railway
BHOPAL, MADHYA PRADESH
West Central Railway
BHOPAL, MADHYA PRADESH
West Central Railway
BHOPAL, MADHYA PRADESH
Indian Army
JAIPUR, RAJASTHAN
Gandhigram Rural Institute Deemed To Be University
DINDIGUL, TAMIL NADU
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Supply of air cooled floor mounted package air conditioner having cooling capacity Q -48 KW min air flow rate 11000 CMH min and pressure head 400 Pa min as per attached technical specification | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-48 KW min air flow rate 11000 CMH min and pressure head 400 Pa min as per attached technical specification | 4 | set | con6.npcil.ten | 300 |
| 2 | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-24.3 KW min air flow rate 4080 CMH min as per attached technical specification | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-24.3 KW min air flow rate 4080 CMH min as per attached technical specification | 8 | set | con6.npcil.ten | 300 |
| 3 | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-32 KW min air flow rate 7000 CMH min and pressure head 600 Pa min as per attached technical specification | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-32 KW min air flow rate 7000 CMH min and pressure head 600 Pa min as per attached technical specification | 4 | set | con6.npcil.ten | 300 |
| 4 | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-10.92 KW min air flow rate 6300 CMH min and pressure head 600 Pa min as per attached technical specification | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-10.92 KW min air flow rate 6300 CMH min and pressure head 600 Pa min as per attached technical specification | 2 | set | con6.npcil.ten | 300 |
| 5 | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-16 KW min air flow rate 4000 CMH min and pressure head 400 Pa min as per attached technical specification | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-16 KW min air flow rate 4000 CMH min and pressure head 400 Pa min as per attached technical specification | 4 | set | con6.npcil.ten | 300 |
| 6 | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-45 KW min air flow rate 9000 CMH min and pressure head 500 Pa min as per attached technical specification | Supply of air cooled floor mounted package air conditioner having cooling capacity Q-45 KW min air flow rate 9000 CMH min and pressure head 500 Pa min as per attached technical specification | 2 | set | con6.npcil.ten | 300 |
| 7 | Supply of ceiling mounted ductable IDU unit of cooling capacity 3 TR air cooled including additional 5 meter copper tube length liquid | Supply of ceiling mounted ductable IDU unit of cooling capacity 3 TR air cooled including additional 5 meter copper tube length liquid and gas line with insulation material and power and communication cable drain line and clamp support as per technical specification. The supply also include IDU units LCD remote controller voltage stabilizer of required rating as per technical specification. | 8 | set | con6.npcil.ten | 300 |
| 8 | Supply of Split system with suspended sub ceiling IDU of cooling capacity 4 TR min air cooled ODU unit including additional 5 meter copper tube length liquid | Supply of Split system with suspended sub ceiling IDU of cooling capacity 4 TR min air cooled ODU unit including additional 5 meter copper tube length liquid and gas line with insulation material and power and communication cable drain line and clamp support as per technical specification. The supply also include IDU units LCD remote controller voltage stabilizer of required rating as per technical specification. | 32 | set | con6.npcil.ten | 300 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Start
17-Feb-2026, 4:00 pm
End
18-Feb-2026, 4:00 pm
Duration: 24 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS