TenderDekho Logo
GEM

Government Tender Published for Mobile Digital Radiography System (V2) in AMBALA, HARYANA

Bid Publish Date

17-Feb-2026, 12:50 pm

Bid End Date

09-Mar-2026, 11:00 am

EMD

₹47,060

Progress

Issue17-Feb-2026, 12:50 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Single Packet Bid

Categories 12

Northern Railway has released a public tender for Mobile Digital Radiography System (V2) (Q2) in AMBALA, HARYANA. Quantity: 1. Submission Deadline: 09-03-2026 11: 00: 00. Download documents and apply online.

Documents 4

GeM-Bidding-8994215.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Mobile Digital Radiography System (V2)

N/a

Posted: 11 December 2024
Closed: 21 December 2024
GEM

Forest Department Madhya Pradesh Mobile Digital Radiography System Tender 2025 Bandhavgarh Umaria ISI ISO compliant

N/a

UMARIA, MADHYA PRADESH

Posted: 27 November 2025
Closed: 22 December 2025
GEM

Mobile Digital Radiography System (V2)

Chacha Nehru Bal Chikitsalaya

EAST DELHI, DELHI

Posted: 22 April 2025
Closed: 20 May 2025
GEM

Mobile Digital Radiography System (V2)

Fakhruddin Ali Ahmed Medical College And Hospital

BARPETA, ASSAM

Posted: 1 February 2025
Closed: 17 February 2025
GEM

Mobile Digital Radiography System (V2)

Secretariat

VIRUDHUNAGAR, TAMIL NADU

Posted: 27 March 2025
Closed: 10 April 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
General Product Description Mobile Digital Radiography System
General Scope of supply Compact, easily transportable, digital mobile radiographic unit with articulated/telescopic arm
Digital Detector Radiography Mode Digital
Digital Detector Number of detector 1
Digital Detector Detector Material Cesium Iodide
Digital Detector Detector Size 14 inches x 17 inches(wireless )
Digital Detector Matrix size 2kx2k
Digital Detector Pixel size in µm <=150
Digital Detector Grey Scale resolution, bits/pixel 14 or better
Digital Detector DQE at 0 LP/mm 65% or more
Digital Detector Machine should have a detector storage compartment Yes
Digital Detector Weight of detector in kg <=5
Digital Detector Detector should be designed and calibrated for General Radiography Purposes and must be fully integrated with the mobile unit including the controls Yes
Digital Detector Detector storage capacity 100 images or more
Control panel for image acquisition Image preview time in seconds <=6
Control panel for image acquisition Control panel Microprocessor controlled
Control panel for image acquisition Automatic parameter selection Yes
Control panel for image acquisition Control panel entry Touch screen
Control panel for image acquisition Anatomic specific post processing Yes
Control panel for image acquisition Display Digital display of mAs and KV and an electronic timer
Control panel for image acquisition Inbuilt console should have touch TFT screen and control Yes
Control panel for image acquisition Console should enable to view the image, and provide post processing features, using touch screen Yes
Control panel for image acquisition Post processing features Zoom, contrast and brightness, adjustment, panning annotate, mark and reporting
X Ray Generator and Tubes High Frequency X-ray Generator Power in KW 3.5 KW
X Ray Generator and Tubes KV range 40-110
X Ray Generator and Tubes Focal spot, mm 0.8 - 2
X Ray Generator and Tubes Heat Capacity, KHU 40-100
X Ray Generator and Tubes Anode Type Stationary
X Ray Generator and Tubes Exposure time in ms 0.1 to 3 Sec
X Ray Generator and Tubes Control Panel and X-Ray Tube Yes
Tube Suspension X Ray tube output should match with generator Yes
Tube Suspension Type of suspension Articulated arm
Tube Suspension Collimator rotation ± 90 degree with on off timer
Ergonomics Unit should have small foot print Yes
Ergonomics Height of the column in cm (Should facilitate easy transportation in the lift and areas with small height doors etc) <=150
Ergonomics Weight of mobile X Ray unit in kg <=600
Ergonomics Cables should be concealed in the arm system Yes
Ergonomics Exposure release switch Detachable with a cord of at least 5 meters.
Workstation Inbuilt work station Yes
Workstation Monitor size in inches 14
Workstation Processor i 5
Workstation RAM in GB 4
Workstation HDD 500 GB
Workstation Dicom compatibility of work station Yes
Workstation Inbuilt console should have touch screen control Yes
Workstation Number of images which can be stored 10000 or more
Workstation Machine should be fully network ready and it should be possible to transfer images and patient data from and to hospital network using LAN connectivity or wireless LAN Yes
Accessories Stitching hardware and software No
Accessories Integration DICOM 3.0 storage SOP Classes
Accessories Lead Apron Yes
Accessories Light weight ‘zero lead’ radiation protection aprons provided Yes
Accessories Lead Aprons - Full body and Skirt type 2 no. each (0.5pb)
Accessories Thyroid shields provided Yes
Accessories Gonadsheet Male provided Yes
Accessories Gonad sheet Female provided Yes
Accessories Extractable measurable tape should be available Yes
Accessories Motorized movement for complete machine No
Accessories Castor wheel Yes
Accessories Unit should have effective breaking system for parking Yes
Accessories Power Requirements 230 V 50 HZ Single phase -16 Ampls socket
Accessories Machine should run on mains as well as battery supply No
Certifications Compliance to Medical Device Rules (MDR) 2017 as amended till date Yes
Certifications Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date Yes
Certifications Certification for manufacturing unit ISO:13485 (Latest)
Certifications Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date Yes
Certifications Conformity to Safety Standards IEC 60601-2-54 or equivalent BIS
Certifications Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement Yes
Certifications Conformity to Indian Standard IS 7620- Part 1, Part 2, Part 3 Yes
Miscellaneous Parameters OEM/Reseller (if supplied to reseller shall ensure uninterputed availabilty of all spares for 10 years) Yes
Miscellaneous Parameters QA, QC and other tests as per NABH shall be carried out by OEM or authorized agency of OEM Yes
Warranty Warranty in Years 5 Or higher

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Past Performance

2

Certificate (Requested in ATC)

3

OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria

4

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

Medical Education Department Uttarakhand Mobile Digital Radiography System Tender Nainital Uttarakhand 2026

N/a

📍 NAINITAL, UTTARAKHAND

EMD: ₹75,000
Est: ₹25.0 L
⏰ Deadline: 1 day left
🛒 Type: Goods
View GEM
Urgent

Mobile Digital Radiography System (V2)

Gujarat Medical Education And Research Society (gmers)

📍 AHMEDABAD, GUJARAT

EMD: ₹1.2 L
⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM
Urgent

Digital Radiography System (V2)

Health Department

📍 PALAKKAD, KERALA

⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM
Urgent

Animal Husbandry Department Uttarakhand Digital Radiography System Tender Nainital 2026 - IS 550/ISO Standards, 3-Year Turnover, 28,000 EMD

N/a

📍 NAINITAL, UTTARAKHAND

EMD: ₹28,000
Est: ₹14.2 L
⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM
Urgent

Dg Armed Forces Medical Service Digital Radiography System Tender 2025 Department of Defence India

Dg Armed Forces Medical Service

⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM