Custom Bid for Services - DEPUTATION OF MANPOWER OF SERVICE ENGINEER OF MS HAYWARD TAYLOROEM FOR TE
Damodar Valley Corporation
Purulia, WEST BENGAL
Bid Publish Date
29-Sep-2025, 5:09 pm
Bid End Date
14-Oct-2025, 6:00 pm
EMD
₹92,175
Value
₹46,08,754
Location
Progress
RAQuantity
671
Category
Provision of Manpower Semi Skilled Manpower
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for Provision of Manpower Semi Skilled Manpower, Provision of Manpower unSkilled Manpower, Comp. mntc of various EMS, Servicing of 500 KVA capacity Diesel Engine Alternator Set, Replacement of following existing faulty 12 Volts Battery, Supplying and installation of EU2 washable coarse filter, Supplying and installation of Synthetic woven washable EU3 filters, Servicing of 7 TR capacity Package AC Units, Servicing of 5 TR capacity Ductable AC Units, Servicing of 1. 5 and2 TR capacity inverter type heating cooling Split, Measurement Testing of earth resistance, Replacement filters R. O. water Purifier system, Replacement S. I. T. C of 36 watt LED surface mounted Batten light, Replacement S. I. T. C of 36 watt LED Panel light 2x2 ft in CENTRAL DELHI, DELHI. Quantity: 671. Submission Deadline: 14-10-2025 18: 00: 00. Submit your proposal before the deadline.
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Damodar Valley Corporation
Purulia, WEST BENGAL
Nhpc Limited
CHAMBA, HIMACHAL PRADESH
Nhpc Limited
CHAMBA, HIMACHAL PRADESH
Hindustan Petroleum Corporation Ltd
PUNE, MAHARASHTRA
N/a
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Provision of Manpower Semi Skilled Manpower | Provision of Manpower for round the clock smooth operation and Comprehensive maintenance of various Electro mechanical services as per details inventory given in relevant sections to keep all the services operational up to the required standards etc. as per specification. The services are 1. Diesel Engine Alternator sets 2. AC Package Units 3. Ductable split AC Units 4. Window and Split AC Units 5. Electrical Installation and fans incl. Electrical APFC Panels 6. R.O. System 7. Water Cooler etc. NOTE 1. This is tentative list of services however it is the responsibility of the agency to operate various services as and when required even during odd night hours as per requirements of BSNL. 2. Agency will make minimum wage payment to all the persons employed either online or by cheque and submit proof of such payment latest by 10th day of every month. Semi Skilled Manpower 1 job means per month salary of a person Items are as per schedule of work item no. 1.1 | 72 | job | ipgsdeed2@nd | 730 |
| 2 | Provision of Manpower unSkilled Manpower | Unskilled Manpower 1 job means per month salary of a person Items are as per schedule of work item no. 1.2 | 72 | job | ipgsdeed2@nd | 730 |
| 3 | Comp. mntc of various EMS | Comprehensive maintenance of various Electro mechanical services as per details and inventory given in relevant sections by deploying the required staff to keep all the services operational up to the required standards etc. as per specification. The services are 1. Diesel Engine Alternator sets 2. AC Package Units 3. Ductable split AC Units 4. Window and Split AC Units 5. Electrical Installation and fans incl Electrical APFC Panels 6. R.O. System 7. Water Cooler etc. NOTE 1. This is tentative list however it is the responsibility of the agency to operate various services as and when required even during odd night hours as per requirements of BSNL and if any additional labour is required the same is to be provided at no extra cost. 2. Agency has to depute his service engineer specialised person during important meeting so that in case of any fault it may be promptly attended to have uninterrupted service of Diesel Engine Alternator sets AC systems and R.O. System. Items are as per schedule of work item no. 2 | 24 | month | ipgsdeed2@nd | 730 |
| 4 | Servicing of 500 KVA capacity Diesel Engine Alternator Set | Servicing of 500 KVA capacity Diesel Engine Alternator Set through OEM Authorized dealers as per manufacturer recommendations including replacement of engine oil and filter cartridges top up of coolant Cleaning of air filter Checking of Vbelt drive and tightness of nuts and bolts Checking of air and water hose piping Checking of engine safety fuel pump Engine protection devices and battery properly tightening of all mounting fasteners including Record engine parameters before and after servicing etc. complete as required.Items are as per schedule of work item no. 3 | 4 | job | ipgsdeed2@nd | 730 |
| 5 | Replacement of following existing faulty 12 Volts Battery | Replacement of 180 AH existing faulty 12 Volts sealed maintenance free Battery of Diesel Engine Alternator Set with new battery having 2 years warranty including making connections replacement of new battery terminals testing etc. Complete as required.Note The faulty battery shall be the property of firm and rate should be quoted accordingly. Items are as per schedule of work item no. 4 | 4 | job | ipgsdeed2@nd | 730 |
| 6 | Supplying and installation of EU2 washable coarse filter | Supplying and installation of EU 2 washable coarse filter having efficiency 90 percentage down to 20 microns filters test certificate of filters to be supplied suitable for AC Package units etc. complete as per manufacturer requirement. Items are as per schedule of work item no. 5 | 10 | sqmtrs | ipgsdeed2@nd | 730 |
| 7 | Supplying and installation of Synthetic woven washable EU3 filters | Supplying and installation of Synthetic woven washable EU3 filters with extruded anodized aluminium frame having an efficiency of 95 percentage down to 5 microns test certificate of filters to be supplied in the plenum for total supply air. The media shall be supported with HDPE mesh on one side and aluminium mesh on other side. Items are as per schedule of work item no. 6 | 5 | sqmtrs | ipgsdeed2@nd | 730 |
| 8 | Servicing of 7 TR capacity Package AC Units | Servicing of 7 TR capacity Pacakage AC Units including washing and cleaning of filters evaporator unit condenser unit including oiling greasing of motors testing commissioning etc. complete as required. Items are as per schedule of work item no. 7 | 40 | job | ipgsdeed2@nd | 730 |
| 9 | Servicing of 5 TR capacity Ductable AC Units | Servicing of 5 TR capacity Ductable AC Units including washing and cleaning of filters evaporator unit condenser unit including oiling greasing of motors testing commissioning etc. complete as required.Items are as per schedule of work item no. 8 | 24 | job | ipgsdeed2@nd | 730 |
| 10 | Servicing of 1.5 and2 TR capacity inverter type heating cooling Split | Servicing of 1.5 or 2 TR capacity inverter type heating cooling Split AC Units including washing and cleaning of filters evaporator unit condenser unit including oiling greasing of motors testing commissioning etc. complete as required. Items are as per schedule of work item no. 9 | 372 | job | ipgsdeed2@nd | 730 |
| 11 | Measurement Testing of earth resistance | Making arrangement for the Measurement Testing of earth resistance of the existing earthing system etc. complete as required.Items are as per schedule of work item no. 10 | 12 | job | ipgsdeed2@nd | 730 |
| 12 | Replacement filters R.O. water Purifier system | Replacement of all the filters suitable for the existing R.O. water Purifier system as per requirement and specification incl. dismantling of existing outlived faulty filters supply of new filters etc. complete as required in all respect to the entire satisfaction of Engineer in charge. Items are as per schedule of work item no. 11 | 2 | job | ipgsdeed2@nd | 730 |
| 13 | Replacement S.I.T. C of 36 watt LED surface mounted Batten light | Replacement Supplying installation Testing and Commissioning of 36 watt LED surface mounted Batten light of CRCA Sheet Body Thickness 0.50 mm body material and construction as per IS 10322 with driver Replaceable as per the requirement with Driver efficiency 85 perc Operating voltage AC 140 270 Volt freq 50 60 hz Operating temp range minus 15 deg to 40 deg centigrade internal surge protection of 2.5 KV with Short and Open circuit protection THD less 10 perc P. F 0.95 IP20 CRI 80 Flicker free flicker should be below 5 perc life time LED Driver electrical circuitry of minimum 50000 Burning Hours with 70 perc of initial Lumen maintained till life ends CCT 3000K 4000K 5700K 6000K 6500K As per ANSI Bin SDCM Standard Deviation Color Matching3 Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate T.C. Manufactures Word Mark Name Engraved Embossing Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect ic Dismantling of existing faulty outlived conventional fixture luminaire connections with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 135 lmWatt output . LM79 LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer in Charge as per requirement. Items are as per schedule of work item 12 | 15 | job | ipgsdeed2@nd | 730 |
| 14 | Replacement S.I.T. C of 36 watt LED Panel light 2x2 ft | ReplacementSupplying installation Testing Commissioning of 36 watt Panel light 2x2 ft of CRCA Sheet Body Thickness 0.50 mm body material and construction as per IS 10322 with driver Replaceable as per the requirement with Driver efficiency 85 perc Operating voltage AC 140 270 Volt freq 50 60 hz Operating temp range min 15 deg to 40 deg centigrade internal surge protection of 2.5 KV with Short Open circuit protection THD 10 perc P. F 0.95 IP20 CRI 80 Flicker free flicker should be below 5 life time LED Driver electrical circuitry of minimum 50000 Burning Hours with 70 of initial Lumen maintained till life ends CCT 3000K 4000K 5700K 6000K6500K As per ANSI Bin SDCM Standard Deviation Color Matching 3 Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate T.C.. Manufactures Word Mark Name Engraved Embossing Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect ic Dismantling of existing faultyoutlived conventional fixtureluminaire connections with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 135 lmmperWatt output . LM79 LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer in Charge as per requirement.Items are as per schedule of work item 13 | 15 | job | ipgsdeed2@nd | 730 |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Start
30-Oct-2025, 3:00 pm
End
31-Oct-2025, 3:00 pm
Duration: 24 hours
Reverse Auction Document
✅ RA concluded. Check financial results for final rankings.
New Delhi Municipal Council
📍 NEW DELHI, DELHI
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS