ICU Ventilators (V2)
Civil Hospital Amdavad
AHMEDABAD, GUJARAT
Progress
Quantity
5
Bid Type
Two Packet Bid
A tender has been published for Gujarat Cancer & Research Institute ICU Ventilators (V2) (Q2) in AHMEDABAD, GUJARAT. Quantity: 5 by. Submission Deadline: 11-07-2026 17: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
ICU Ventilators (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Civil Hospital Amdavad
AHMEDABAD, GUJARAT
N/a
AHMEDABAD, GUJARAT
Vadodara District Panchayat
Nmdc Limited
BELLARY, KARNATAKA
National Animal Resource Facility For Biomedical Research
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PRODUCT INFORMATION | Patient Type | Adult & pediatric |
| PRODUCT INFORMATION | Type of technology | Turbine |
| PRODUCT INFORMATION | Tidal volume in ml | (20 ml or less) to (1500 ml or more) |
| PRODUCT INFORMATION | Respiration rate, breaths/min | up to 80 or more |
| PRODUCT INFORMATION | Trigger mechanism | Pressure /flow |
| PRODUCT INFORMATION | Inspiratory flow rate, L/min | upto 200 or more |
| PRODUCT INFORMATION | Inspiratory pressure, cm H2O | upto 50 or more |
| PRODUCT INFORMATION | IE ratio | 1:10 to 4:1 |
| PRODUCT INFORMATION | Sigh breath function | Yes |
| PRODUCT INFORMATION | Control panel lock | Yes |
| PRODUCT INFORMATION | Facility for double lung ventilation | Yes |
| PATIENT ASSESSMENT TOOLS | Number of loops | 2 loops (P-V, F-V) |
| PATIENT ASSESSMENT TOOLS | Lung recruitment tools (PV loops) / OLT (Open lung tools) | No |
| PATIENT ASSESSMENT TOOLS | Lung mechanics visualization tool | No |
| PATIENT ASSESSMENT TOOLS | Capnography/CO2 monitoring | Yes |
| PATIENT ASSESSMENT TOOLS | Esophageal / transpulmonary pressure monitoring | No |
| PATIENT ASSESSMENT TOOLS | APRV(Airway Pressure Release Ventilation) /Bivent/Bi level | Yes |
| PATIENT ASSESSMENT TOOLS | MMV(Mandatory Minute Ventilation) + PSV (Pressure Support Ventilation) /ASV( Adaptive Support Ventilation ) or ALPV(Adaptive Lung Protection Ventilation) or Automode | Yes |
| PATIENT ASSESSMENT TOOLS | PRVC(Pressure-Regulated Volume Control ventilation)/Auto flow | Yes |
| PATIENT ASSESSMENT TOOLS | High flow oxygen therapy | Yes |
| PATIENT ASSESSMENT TOOLS | Automatic weaning system provided | Yes |
| PATIENT ASSESSMENT TOOLS | Volume Support | No |
| PATIENT ASSESSMENT TOOLS | RSBI (Rapid Shallow Breathing Index) | Yes |
| PATIENT ASSESSMENT TOOLS | Expiratory Time constant ( Tcexp) | Yes |
| PATIENT ASSESSMENT TOOLS | Compliance static and/or dynamic | Yes |
| PATIENT ASSESSMENT TOOLS | Inspired and/or expired resistance | Yes |
| PATIENT ASSESSMENT TOOLS | Occlusion pressure | No |
| PATIENT ASSESSMENT TOOLS | Inspiratory and expiratory hold | Yes |
| PATIENT ASSESSMENT TOOLS | Spontaneous frequency | Yes |
| PATIENT ASSESSMENT TOOLS | Total peep, intrinsic peep, extrinsic peep | Yes |
| PATIENT ASSESSMENT TOOLS | Expiratory block is autoclavable and no routine calibration required | Yes |
| PATIENT ASSESSMENT TOOLS | Auto compensation for ET Tube | No |
| PATIENT ASSESSMENT TOOLS | Facility for automatic compliance & Leakage compensation for circuit available | Yes |
| PATIENT ASSESSMENT TOOLS | RS 232 out put port | Yes |
| PATIENT ASSESSMENT TOOLS | USB/Memory card | No |
| PATIENT ASSESSMENT TOOLS | Availability of Remote alarm/display port | Yes |
| PATIENT ASSESSMENT TOOLS | Facility to Report (vent alarms and patient status) | Yes |
| PATIENT ASSESSMENT TOOLS | HL/7 Compliant out put | Yes |
| PATIENT ASSESSMENT TOOLS | Type of coloured display | LED/LCD/TFT |
| PATIENT ASSESSMENT TOOLS | Display should be touch screen | Yes |
| PATIENT ASSESSMENT TOOLS | NIV (Non Invasive Ventilation) to be possible in all modes of ventilation available | Yes |
| PATIENT ASSESSMENT TOOLS | Minimum Size of display (±2%) | 12.0 |
| PATIENT ASSESSMENT TOOLS | Graphic display have automatic scaling facility for waves | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Provision of UPS | No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time in hrs | NA if not provided |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Built in air source | Turbine (In built) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Availability of stand alone compressor | No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Compressor shall provide an oil free Medical air, with Peak output flow should be minimum 150 LPM and Air quality complying with ISO compressed air purity class | NA (for turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Seller shall ensure compatibility of compressor with ventilator | NA (for Turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Nebulizer with particle size less than 3 micron | Yes |
| ADDITIONAL ACCESSORIES | Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire | 1 |
| WARRANTY | Warranty (years) | 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sher-i-kashmir Institute Of Medical Sciences Srinagar
📍 SRINAGAR, JAMMU & KASHMIR
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Regional Institute Of Medical Sciences Imphal Manipur
📍 IMPHAL WEST, MANIPUR
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS