SITC new Emergency and MV panel,Supply aluminum armoured power cable 1,Supply aluminum armoured pow
Bharat Sanchar Nigam Limited Portal(bsnl)
KAMRUP, ASSAM
Bid Publish Date
12-Mar-2026, 12:38 pm
Bid End Date
02-Apr-2026, 2:00 pm
EMD
₹59,233
Value
₹29,61,630
Location
Progress
Quantity
3287
Category
SITC of ACB Panel
Bid Type
Two Packet Bid
A tender has been published for Bharat Sanchar Nigam Limited Portal(bsnl) SITC of ACB Panel, Dismantling section of the existing 800 A bus trunking, Rerouting and reinstallation of a section of bus trunking, Supply and fixing 3 mm thick MS sheet, Supply and Fixing mechanical interlocking arrangement with lockable trip push button key, Making necessary modification in the existing 800 A main LT panel bus bar arrangement, Supply, fixing, testing of Multifunction meter, Supply and fixing LED type RYB Indicating Lamps, Dismantling the existing APFC panel, Supplying and fixing fire retardant electrically insulated, synthetic mat, SITC of 4. 5 Kg CO2 type fire extinguisher, SITC of 5 Kg DCP type fire extinguisher, Supply and Fixing of GI Fire Buckets, Providing and laying 6mm thick MS chequered sheet, Complete painting of the existing rusted chequred plates, Preparing the single line diagram of 2x400kVA HT substation, Supply and fixing the signage, Removing the sand in fire buckets, Supply and fixing 18 W, 4 feet LED batten tube light fitting, Complete cleaning of the existing substation room, Supplying and fixing 15 or 16 A Switch and 6 pin 15 or 16 amp socket outlet on metal box, Supplying, installation including suspension, testing and commissioning of 800 Amps bus trunking, Supplying of 3. 5 C x 400 sq. mm cable, Supplying of 3. 5 C x 300 sq. mm cable, Laying of one number PVC insulated power cable in existing pipe, Laying of one number PVC insulated power cable in existing masonry duct, Laying of one number PVC insulated power cable on surface of wall, Supply, fabrication and erection of MS Cable tray, Supplying and laying of 200 mm dia DWC HDPE pipe, Providing and fixing earth bus of 50 mm X 5 mm copper strip, Providing and fixing braided copper of equivalent size of 25mm x 5mm strip, Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick, Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G. I. pipe, Providing and fixing 25 mm X 5 mm copper strip on surface, Supplying and making end termination with brass compression gland for 3. 5 X 400 sq. mm cable, Supplying and making end termination with brass compression gland for 3. 5 X 300 sq. mm cable in ERNAKULAM, KERALA. Quantity: 3287 by. Submission Deadline: 02-04-2026 14: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
SITC of ACB Panel , Dismantling section of the existing 800 A bus trunking , Rerouting and reinstallation of a section of bus trunking , Supply and fixing 3 mm thick MS sheet , Supply and Fixing mechanical interlocking arrangement with lockable trip push button key , Making necessary modification in the existing 800 A main LT panel bus bar arrangement , Supply , fixing, testing of Multifunction meter , Supply and fixing LED type RYB Indicating Lamps , Dismantling the existing APFC panel , Supplying and fixing fire retardant electrically insulated, synthetic mat , SITC of 4.5 Kg CO2 type fire extinguisher , SITC of 5 Kg DCP type fire extinguisher , Supply and Fixing of GI Fire Buckets , Providing and laying 6mm thick MS chequered sheet , Complete painting of the existing rusted chequred plates , Preparing the single line diagram of 2x400kVA HT substation , Supply and fixing the signage , Removing the sand in fire buckets , Supply and fixing 18 W, 4 feet LED batten tube light fitting , Complete cleaning of the existing substation room , Supplying and fixing 15 or 16 A Switch and 6 pin 15 or 16 amp socket outlet on metal box , Supplying, installation including suspension, testing and commissioning of 800 Amps bus trunking , Supplying of 3.5 C x 400 sq.mm cable , Supplying of 3.5 C x 300 sq.mm cable , Laying of one number PVC insulated power cable in existing pipe , Laying of one number PVC insulated power cable in existing masonry duct , Laying of one number PVC insulated power cable on surface of wall , Supply, fabrication and erection of MS Cable tray , Supplying and laying of 200 mm dia DWC HDPE pipe , Providing and fixing earth bus of 50 mm X 5 mm copper strip , Providing and fixing braided copper of equivalent size of 25mm x 5mm strip , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick , Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe , Providing and fixing 25 mm X 5 mm copper strip on surface , Supplying and making end termination with brass compression gland for 3.5 X 400 sq. mm cable , Supplying and making end termination with brass compression gland for 3.5 X 300 sq. mm cable
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Bharat Sanchar Nigam Limited Portal(bsnl)
KAMRUP, ASSAM
Bharat Sanchar Nigam Limited Portal(bsnl)
JODHPUR, RAJASTHAN
Bharat Sanchar Nigam Limited Portal(bsnl)
PATNA, BIHAR
Bharat Sanchar Nigam Limited Portal(bsnl)
PATNA, BIHAR
Hindustan Petroleum Corporation Ltd
EAST GODAVARI, ANDHRA PRADESH
Tender Results
Loading results...
SITC of ACB Panel
SITC of ACB Panel with 2 Nos. 800 A, 4-Pole horizontal draw out type Air Circuit Breakers of fault breaking capacity 50 kA as incomer with mechanical interlock arrangement and 1 No. 800 A, 4-Pole horizontal draw out type Air Circuit Breakers of fault breaking capacity 50 kA as outgoings with necessary metering as well as protection unit.
Dismantling section of the existing 800 A bus trunking
Dismantling section of the existing 800 A bus trunking from Transformers to existing MV Panel with aluminium bus bar
Rerouting and reinstallation of a section of bus trunking
Rerouting and reinstallation of a section of bus trunking and minor modifications from the 2 Nos. existing transformers to new ACB panel etc as reqd
Supply and fixing 3 mm thick MS sheet
Supply and fixing 3 mm thick MS sheet for closing the existing opening of the removed bus trunkings
Supply and Fixing mechanical interlocking arrangement with lockable trip push button key
Supply and Fixing mechanical interlocking arrangement with lockable trip push button key between 2 Nos incomer ACBs with 2 locks and 1 key suitable for existing 800 A incoming ACBs in the main LT Panel
Making necessary modification in the existing 800 A main LT panel bus bar arrangement
Making necessary modification in the existing 800 A main LT panel bus bar arrangement to interconnect between essential and non essential section of the panel
Supply , fixing, testing of Multifunction meter
Supply , fixing, testing of Multifunction meter with LCD disply , class 1 accuracy in the existing main LT panel
Supply and fixing LED type RYB Indicating Lamps
Supply and fixing LED type RYB Indicating Lamps with toggle switch and 2 A MCBs on DIN channel
Dismantling the existing APFC panel
Dismantling the existing APFC panel of approximate size 1.8 M x 2 M x 0.4 M after carefully disconnecting the cable terminations from both the end
Supplying and fixing fire retardant electrically insulated, synthetic mat
Supplying and fixing fire retardant electrically insulated, synthetic mat not less than 2mm thick, suitable for all voltages not exceeding 1.1KV
SITC of 4.5 Kg CO2 type fire extinguisher
SITC of 4.5 Kg CO2 type fire extinguisher
SITC of 5 Kg DCP type fire extinguisher
SITC of 5 Kg DCP type fire extinguisher
Supply and Fixing of GI Fire Buckets
Providing and fixing one set comprising two numbers of GI fire buckets of 9 litre capacity each
Providing and laying 6mm thick MS chequered sheet
Providing and laying 6mm thick MS chequered sheet with 25mm x 25mm x 5mm angle iron on the bottom
Complete painting of the existing rusted chequred plates
Complete painting of the existing rusted chequred plates and its angle iron support frame above the cable trench
Preparing the single line diagram of 2x400kVA HT substation
Preparing the single line diagram of 2x400kVA HT substation HT substation , after incorporating the modification done in the existing system
Supply and fixing the signage
Supply and fixing the signage using adhesive type vinyl paper on the existing panel board
Removing the sand in fire buckets
Removing the sand in fire buckets cleaning the bucket, sieving the sand to remove the dirt and debris and refilling the bucket
Supply and fixing 18 W, 4 feet LED batten tube light fitting
Supply and fixing 18 W, 4 feet LED batten tube light fitting
Complete cleaning of the existing substation room
Complete cleaning of the existing substation room
Supplying and fixing 15 or 16 A Switch and 6 pin 15 or 16 amp socket outlet on metal box
Supplying and fixing 15 or 16 A Switch and 6 pin 15 or 16 amp socket outlet on metal box of 180 mm x 100 mm x 60 mm size
Supplying, installation including suspension, testing and commissioning of 800 Amps bus trunking
Supplying, installation including suspension, testing and commissioning of 800 Amps bus trunking with aluminium bus bars
Supplying of 3.5 C x 400 sq.mm cable
Supplying of one No. PVC-sheathed XLPE insulated aluminium armoured 3.5 C x 400 sq.mm power cable
Supplying of 3.5 C x 300 sq.mm cable
Supplying of one No. PVC-sheathed XLPE insulated aluminium armoured 3.5 C x 300 sq.mm power cable
Laying of one number PVC insulated power cable in existing pipe
Laying of one number PVC insulated power cable in existing pipe
Laying of one number PVC insulated power cable in existing masonry duct
Laying of one number PVC insulated power cable in existing masonry duct
Laying of one number PVC insulated power cable on surface of wall
Laying of one number PVC insulated power cable on surface of wall
Supply, fabrication and erection of MS Cable tray
Supply, fabrication and erection of MS Cable tray with suitable size MS angle Iron
Supplying and laying of 200 mm dia DWC HDPE pipe
Supplying and laying of 200 mm dia DWC HDPE pipe
Providing and fixing earth bus of 50 mm X 5 mm copper strip
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface
Providing and fixing braided copper of equivalent size of 25mm x 5mm strip
Providing and fixing braided copper of equivalent size of 25mm x 5mm strip
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe
Providing and fixing 25 mm X 5 mm copper strip on surface
Providing and fixing 25 mm X 5 mm copper strip on surface
Supplying and making end termination with brass compression gland for 3.5 X 400 sq. mm cable
Supplying and making end termination with brass compression gland 3.5 X 400 sq. mm cable
Supplying and making end termination with brass compression gland for 3.5 X 300 sq. mm cable
Supplying and making end termination with brass compression gland for 3.5 X 300 sq. mm cable
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | SITC of ACB Panel | SITC of ACB Panel with 2 Nos. 800 A, 4-Pole horizontal draw out type Air Circuit Breakers of fault breaking capacity 50 kA as incomer with mechanical interlock arrangement and 1 No. 800 A, 4-Pole horizontal draw out type Air Circuit Breakers of fault breaking capacity 50 kA as outgoings with necessary metering as well as protection unit. | 1 | job | jtoeekm2 | 120 | |
| 2 | Dismantling section of the existing 800 A bus trunking | Dismantling section of the existing 800 A bus trunking from Transformers to existing MV Panel with aluminium bus bar | 1 | job | jtoeekm2 | 120 | |
| 3 | Rerouting and reinstallation of a section of bus trunking | Rerouting and reinstallation of a section of bus trunking and minor modifications from the 2 Nos. existing transformers to new ACB panel etc as reqd | 1 | job | jtoeekm2 | 120 | |
| 4 | Supply and fixing 3 mm thick MS sheet | Supply and fixing 3 mm thick MS sheet for closing the existing opening of the removed bus trunkings | 2 | sq mtrs | jtoeekm2 | 120 | |
| 5 | Supply and Fixing mechanical interlocking arrangement with lockable trip push button key | Supply and Fixing mechanical interlocking arrangement with lockable trip push button key between 2 Nos incomer ACBs with 2 locks and 1 key suitable for existing 800 A incoming ACBs in the main LT Panel | 1 | job | jtoeekm2 | 120 | |
| 6 | Making necessary modification in the existing 800 A main LT panel bus bar arrangement | Making necessary modification in the existing 800 A main LT panel bus bar arrangement to interconnect between essential and non essential section of the panel | 1 | job | jtoeekm2 | 120 | |
| 7 | Supply , fixing, testing of Multifunction meter | Supply , fixing, testing of Multifunction meter with LCD disply , class 1 accuracy in the existing main LT panel | 2 | jobs | jtoeekm2 | 120 | |
| 8 | Supply and fixing LED type RYB Indicating Lamps | Supply and fixing LED type RYB Indicating Lamps with toggle switch and 2 A MCBs on DIN channel | 2 | sets | jtoeekm2 | 120 | |
| 9 | Dismantling the existing APFC panel | Dismantling the existing APFC panel of approximate size 1.8 M x 2 M x 0.4 M after carefully disconnecting the cable terminations from both the end | 1 | job | jtoeekm2 | 120 | |
| 10 | Supplying and fixing fire retardant electrically insulated, synthetic mat | Supplying and fixing fire retardant electrically insulated, synthetic mat not less than 2mm thick, suitable for all voltages not exceeding 1.1KV | 2 | sq mtrs | jtoeekm2 | 120 | |
| 11 | SITC of 4.5 Kg CO2 type fire extinguisher | SITC of 4.5 Kg CO2 type fire extinguisher | 2 | nos | jtoeekm2 | 120 | |
| 12 | SITC of 5 Kg DCP type fire extinguisher | SITC of 5 Kg DCP type fire extinguisher | 2 | nos | jtoeekm2 | 120 | |
| 13 | Supply and Fixing of GI Fire Buckets | Providing and fixing one set comprising two numbers of GI fire buckets of 9 litre capacity each | 2 | sets | jtoeekm2 | 120 | |
| 14 | Providing and laying 6mm thick MS chequered sheet | Providing and laying 6mm thick MS chequered sheet with 25mm x 25mm x 5mm angle iron on the bottom | 1 | sq mtrs | jtoeekm2 | 120 | |
| 15 | Complete painting of the existing rusted chequred plates | Complete painting of the existing rusted chequred plates and its angle iron support frame above the cable trench | 16 | sq mtrs | jtoeekm2 | 120 | |
| 16 | Preparing the single line diagram of 2x400kVA HT substation | Preparing the single line diagram of 2x400kVA HT substation HT substation , after incorporating the modification done in the existing system | 3 | sq mtrs | jtoeekm2 | 120 | |
| 17 | Supply and fixing the signage | Supply and fixing the signage using adhesive type vinyl paper on the existing panel board | 2,000 | sq cms | jtoeekm2 | 120 | |
| 18 | Removing the sand in fire buckets | Removing the sand in fire buckets cleaning the bucket, sieving the sand to remove the dirt and debris and refilling the bucket | 4 | jobs | jtoeekm2 | 120 | |
| 19 | Supply and fixing 18 W, 4 feet LED batten tube light fitting | Supply and fixing 18 W, 4 feet LED batten tube light fitting | 2 | nos | jtoeekm2 | 120 | |
| 20 | Complete cleaning of the existing substation room | Complete cleaning of the existing substation room | 1 | job | jtoeekm2 | 120 | |
| 21 | Supplying and fixing 15 or 16 A Switch and 6 pin 15 or 16 amp socket outlet on metal box | Supplying and fixing 15 or 16 A Switch and 6 pin 15 or 16 amp socket outlet on metal box of 180 mm x 100 mm x 60 mm size | 1 | job | jtoeekm2 | 120 | |
| 22 | Supplying, installation including suspension, testing and commissioning of 800 Amps bus trunking | Supplying, installation including suspension, testing and commissioning of 800 Amps bus trunking with aluminium bus bars | 2 | mtrs | jtoeekm2 | 120 | |
| 23 | Supplying of 3.5 C x 400 sq.mm cable | Supplying of one No. PVC-sheathed XLPE insulated aluminium armoured 3.5 C x 400 sq.mm power cable | 300 | mtrs | jtoeekm2 | 120 | |
| 24 | Supplying of 3.5 C x 300 sq.mm cable | Supplying of one No. PVC-sheathed XLPE insulated aluminium armoured 3.5 C x 300 sq.mm power cable | 150 | mtrs | jtoeekm2 | 120 | |
| 25 | Laying of one number PVC insulated power cable in existing pipe | Laying of one number PVC insulated power cable in existing pipe | 44 | mtrs | jtoeekm2 | 120 | |
| 26 | Laying of one number PVC insulated power cable in existing masonry duct | Laying of one number PVC insulated power cable in existing masonry duct | 142 | mtrs | jtoeekm2 | 120 | |
| 27 | Laying of one number PVC insulated power cable on surface of wall | Laying of one number PVC insulated power cable on surface of wall | 264 | mtrs | jtoeekm2 | 120 | |
| 28 | Supply, fabrication and erection of MS Cable tray | Supply, fabrication and erection of MS Cable tray with suitable size MS angle Iron | 200 | kg | jtoeekm2 | 120 | |
| 29 | Supplying and laying of 200 mm dia DWC HDPE pipe | Supplying and laying of 200 mm dia DWC HDPE pipe | 15 | mtrs | jtoeekm2 | 120 | |
| 30 | Providing and fixing earth bus of 50 mm X 5 mm copper strip | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface | 1 | mtrs | jtoeekm2 | 120 | |
| 31 | Providing and fixing braided copper of equivalent size of 25mm x 5mm strip | Providing and fixing braided copper of equivalent size of 25mm x 5mm strip | 3 | mtrs | jtoeekm2 | 120 | |
| 32 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories | 2 | nos | jtoeekm2 | 120 | |
| 33 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe | 30 | mtrs | jtoeekm2 | 120 | |
| 34 | Providing and fixing 25 mm X 5 mm copper strip on surface | Providing and fixing 25 mm X 5 mm copper strip on surface | 70 | mtrs | jtoeekm2 | 120 | |
| 35 | Supplying and making end termination with brass compression gland for 3.5 X 400 sq. mm cable | Supplying and making end termination with brass compression gland 3.5 X 400 sq. mm cable | 12 | nos | jtoeekm2 | 120 | |
| 36 | Supplying and making end termination with brass compression gland for 3.5 X 300 sq. mm cable | Supplying and making end termination with brass compression gland for 3.5 X 300 sq. mm cable | 4 | nos | jtoeekm2 | 120 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Airports Authority Of India
📍 COIMBATORE, TAMIL NADU
Hindustan Shipyard Limited (hsl)
Hindustan Petroleum Corporation Ltd
📍 TUMKUR, KARNATAKA
Uttar Pradesh Power Corporation Limited (uppcl)
📍 ETAH, UTTAR PRADESH
Bharat Sanchar Nigam Limited Portal(bsnl)
📍 AHMEDABAD, GUJARAT
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS