DC Electronic Load
Hindustan Aeronautics Limited (hal)
Rangareddi, TELANGANA
Progress
Quantity
1
Bid Type
Two Packet Bid
Office Of Dg (mss) invites bids for DC Electronic Load (Q3) in HYDERABAD, TELANGANA. Quantity: 1. Submission Deadline: 06-07-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
DC Electronic Load (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Hindustan Aeronautics Limited (hal)
Rangareddi, TELANGANA
Indian Air Force
JAMNAGAR, GUJARAT
Nuclear Power Corporation Of India Limited
TIRUNELVELI, TAMIL NADU
Indian Space Research Organization
NELLORE, ANDHRA PRADESH
Indian Space Research Organization
THIRUVANANTHAPURAM, KERALA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | DC electronic load system suitable for testing of | DC Power Sources |
| GENERIC | Compatible for testing of batteries | Yes for all type of batteries |
| GENERIC | Operating Mode | Constant Current, Constant Voltage, Constant Resistance, Constant Power, Dynamic Mode |
| CONSTRUCTION | Mounting arrangement | Table top/Desk top |
| CONSTRUCTION | Memory Capacity | Up to 100 sets of measurements |
| CONSTRUCTION | Power off memory function | Yes |
| CONSTRUCTION | Protection for | Over Voltage, Over current, Over power, Over temperature, Current limiting, Power limiting |
| CONSTRUCTION | Standard accessoires | Power cord, Operating instruction Manuals, Safety information and Driver CDs |
| INTERFACE | USB Device interface | 1 No. with cable |
| INTERFACE | USB Host Interface | 1 No. with cable |
| INTERFACE | LAN Interface | 1 No. |
| INTERFACE | RS232 | 1 No. |
| INTERFACE | Digital I/O | Yes |
| INTERFACE | GPIB | 1 No. |
| ENVIRONMENT | Cooling Method | Fan cooled |
| ENVIRONMENT | Operating Temperature (in deg. C) | 0 to 40 |
| ENVIRONMENT | Storage temperature | -20 to +70 |
| ENVIRONMENT | Altitude | < 2000 m |
| ENVIRONMENT | Degree of protection, IP rating | IP 20 |
| INPUT RATINGS | Voltage range (in Volts) | 0 to 150 |
| INPUT RATINGS | Current range, High (in Amps) | 0 to 40 |
| INPUT RATINGS | Maximum power (in Watts) | 200 |
| INPUT RATINGS | Test lead supporting for maximum voltage and maximum current for each DC Electronic Load System | Yes. Included with 1 m length |
| CONSTANT CURRENT MODE | Low range (in A) | 0 to 3 |
| CONSTANT CURRENT MODE | High range (n A) | 0 to 15, 0 to 20, 0 to 30, 0 to 40, 0 to 60, 0 to 80, 0 to 120 |
| CONSTANT CURRENT MODE | Resolution Low (in mA) | 0.1, 1 |
| CONSTANT CURRENT MODE | Resolution High (in mA) | 1, 10 |
| CONSTANT CURRENT MODE | Low range accuracy | 0.1% + 5 mA, ± 0.2% ± 30mA |
| CONSTANT CURRENT MODE | High range accuracy | 0.1% + 10 mA, ± 0.2% ± 30mA |
| CONSTANT VOLTAGE MODE | Low range (in Volts) | 0 to 6, 0 to 8, 0 to 15 |
| CONSTANT VOLTAGE MODE | High range (in Volts) | 0 to 60, 0 to 80, 0 to 150 |
| CONSTANT VOLTAGE MODE | Resolution Low (in mV) | 1 |
| CONSTANT VOLTAGE MODE | Resolution High (in mV) | 5, 10 |
| CONSTANT VOLTAGE MODE | Low range accuracy. | 0.1% + 3 mV |
| CONSTANT VOLTAGE MODE | High range accuracy. | 0.1% + 8 mV |
| CONSTANT RESISTANCE MODE | Low Range (in Ohms) | 0.04 to 10, 0.05 to 10, 0.08 to 15, 0.1 to 10, 0.15 to 10, 0.25 to 10, 0.3 to 10 |
| CONSTANT RESISTANCE MODE | High Range (in Ohms) | 2 to 15, 10 to 7.5, 10 to 99, 2 to 400 |
| CONSTANT RESISTANCE MODE | Resolution Low (in Ohm) | 0.001, 0.01 |
| CONSTANT RESISTANCE MODE | Resolution High (in Ohm) | 0.1 |
| CONSTANT RESISTANCE MODE | Accuracy Low | 0.01% + 0.08 S |
| CONSTANT RESISTANCE MODE | Accuracy High | 0.01% + 0.0008s |
| READ BACK VOLTAGE | Voltage range , Low | 0 to 6 V, 0 to 16 V, 0 to 18 V, 0 to 50 V |
| READ BACK VOLTAGE | Voltage range , High | 0 to 80 V, 0 to 120 V, 0 to 150 V, 0 to 500 V |
| READ BACK VOLTAGE | Resolution, Low | 0.1 mV, 1 mV |
| READ BACK VOLTAGE | Resolution, High | 1 mV, 10 mV |
| READ BACK VOLTAGE | Accuracy, Low | ±(0.025% + 0.025% FS) |
| READ BACK VOLTAGE | Accuracy, High | ±(0.025% + 0.025% FS) |
| READ BACK CURRENT | Current range , Low | 0 to 2 A, 0 to 3 A, 0 to 4 A, 0 to 6 A |
| READ BACK CURRENT | Current range , High | 0 to 15 A, 0 to 30 A, 0 to 40 A, 0 to 60 A |
| READ BACK CURRENT | Resolution, Low. | 0.01 mV, 1 mV |
| READ BACK CURRENT | Resolution, High. | 0.1 mV, 1 mV |
| READ BACK CURRENT | Accuracy, Low. | ±(0.05% + 0.05% FS) |
| READ BACK CURRENT | Accuracy, High. | ±(0.05% + 0.05% FS) |
| EXTERNAL ANALOG PROGRAMMING | Voltage programming accuracy | 0.5% + 12 mV |
| EXTERNAL ANALOG PROGRAMMING | Current programming accuracy | 0.25% + 4.5 mA |
| EXTERNAL MONITOR PORTS | Voltage monitor accuracy | 0.25% + 12 mV |
| EXTERNAL MONITOR PORTS | Current monitor accuracy | 0.1% + 4.5 mA |
| CERTIFICATIONS | Safety Compliance and test Certificate | as per IEC 61010-1, as per EN 61010- 1 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Odisha Power Generation Corporation Limited
📍 JHARSUGUDA, ODISHA
Southern Railway
📍 KANCHIPURAM, TAMIL NADU
Power Grid Corporation Of India Limited
📍 JAMMU, JAMMU & KASHMIR
Indian Air Force
📍 KAMRUP, ASSAM
Office Of Dg (mss)
📍 HYDERABAD, TELANGANA
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification